Draeger Chlorobenzene Detector Tubes
1 Draeger short-term detector tube for Chlorobenzene, measuring range 5 to 200 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 156); prices are live. Ships in 1–2 business days.
Every Draeger tube for Chlorobenzene
| Part number | Tube | Measuring range | Strokes (n) | Measuring time | Color change | Pack | Price | |
|---|---|---|---|---|---|---|---|---|
| 6728761 | Draeger Chlorobenzene 5/a Detector Tubes, Box of 5 | 5 to 200 ppm | 10 | approx. 3 min | blue → yellow-gray | Box of 5 | $96.86 |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 156, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.
Chlorobenzene exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | TWA 75 ppm (350 mg/m³) |
| NIOSH REL | |
| NIOSH IDLH | 1000 ppm |
| CAS number | 108-90-7 |
| Formula | C₆H₅Cl |
| Other names | Benzene chloride, Chlorobenzol, MCB, Monochlorobenzene, Phenyl chloride |
| Conversion | 1 ppm = 4.61 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Chlorobenzene (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless liquid with an almond-like odor.
Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.
Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.
Draeger Chlorobenzene tube questions
Which Draeger tubes measure Chlorobenzene? 6728761 (5 to 200 ppm).
What is the lowest range Draeger tube for Chlorobenzene? 6728761, 5 to 200 ppm, 10 strokes.
What is the OSHA exposure limit for Chlorobenzene? OSHA PEL TWA 75 ppm (350 mg/m³); NIOSH REL ; IDLH 1000 ppm (NIOSH Pocket Guide).
Which pump reads Draeger Chlorobenzene tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.
Do Draeger Chlorobenzene tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).