Skip to main content

Draeger Chloroform Detector Tubes

1 Draeger short-term detector tube for Chloroform, measuring range 2 to 10 ppm / 20 to 80 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 157); prices are live. Ships in 1–2 business days.

Every Draeger tube for Chloroform

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
6728861Draeger Chloroform 2/b Detector Tubes, Box of 52 to 10 ppm / 20 to 80 ppm10 /3approx. 9 min / approx. 3 minwhite → purpleBox of 5$196.47

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 157, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Chloroform exposure limits

LimitValue
OSHA PELC 50 ppm (240 mg/m³)
NIOSH RELCa ST 2 ppm (9.78 mg/m³) [60-minute]
NIOSH IDLHCa [500 ppm]
CAS number67-66-3
FormulaCHCl₃
Other namesMethane trichloride, Trichloromethane
Conversion1 ppm = 4.88 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Chloroform (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless liquid with a pleasant odor.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Chloroform tube questions

Which Draeger tubes measure Chloroform? 6728861 (2 to 10 ppm / 20 to 80 ppm).

What is the lowest range Draeger tube for Chloroform? 6728861, 2 to 10 ppm / 20 to 80 ppm, 10 /3 strokes.

What is the OSHA exposure limit for Chloroform? OSHA PEL C 50 ppm (240 mg/m³); NIOSH REL Ca ST 2 ppm (9.78 mg/m³) [60-minute]; IDLH Ca [500 ppm] (NIOSH Pocket Guide).

Which pump reads Draeger Chloroform tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Chloroform tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.