Skip to main content
Draeger detector tubes · Chloromethane

Draeger Chloromethane Detector Tubes

1 Draeger short-term detector tube for Chloromethane, measuring range 10 to 100 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 159); prices are live. Ships in 1–2 business days.

Every Draeger tube for Chloromethane

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8103911Draeger Chloromethane 10/a Detector Tubes, Box of 1010 to 100 ppm8approx. 4 minwhite  blue-greenBox of 10$214.05

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 159, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Chloromethane exposure limits

LimitValue
OSHA PELTWA 100 ppm C 200 ppm 300 ppm (5-minute maximum peak in any 3 hours)
NIOSH RELCa
NIOSH IDLHCa [2000 ppm]
CAS number74-87-3
FormulaCH₃Cl
Other namesChloromethane, Monochloromethane
Conversion1 ppm = 2.07 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Methyl chloride (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless gas with a faint, sweet odor which is not noticeable at dangerous concentrations. [Note: Shipped as a liquefied compressed gas.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Chloromethane tube questions

Which Draeger tubes measure Chloromethane? 8103911 (10 to 100 ppm).

What is the lowest range Draeger tube for Chloromethane? 8103911, 10 to 100 ppm, 8 strokes.

What is the OSHA exposure limit for Chloromethane? OSHA PEL TWA 100 ppm C 200 ppm 300 ppm (5-minute maximum peak in any 3 hours); NIOSH REL Ca; IDLH Ca [2000 ppm] (NIOSH Pocket Guide).

Which pump reads Draeger Chloromethane tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Chloromethane tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.