Draeger detector tubes · Cyclohexane

Draeger Cyclohexane Detector Tubes

1 Draeger short-term detector tube for Cyclohexane, measuring range 40 to 200 ppm / 300 to 3000 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 165); prices are live. Ships in 1–2 business days.

Every Draeger tube for Cyclohexane

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8103671Draeger Cyclohexane 40/a Detector Tubes, Box of 1040 to 200 ppm / 300 to 3000 ppm5 /1approx. 75 s / 15 swhite → brown-greenBox of 10$152.82

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 165, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Cyclohexane exposure limits

LimitValue
OSHA PELTWA 300 ppm (1050 mg/m³)
NIOSH RELTWA 300 ppm (1050 mg/m³)
NIOSH IDLH1300 ppm [10%LEL]
CAS number110-82-7
FormulaC₆H₁₂
Other namesBenzene hexahydride, Hexahydrobenzene, Hexamethylene, Hexanaphthene
Conversion1 ppm = 3.44 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Cyclohexane (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless liquid with a sweet, chloroform-like odor. [Note: A solid below 44°F.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Cyclohexane tube questions

Which Draeger tubes measure Cyclohexane? 8103671 (40 to 200 ppm / 300 to 3000 ppm).

What is the lowest range Draeger tube for Cyclohexane? 8103671, 40 to 200 ppm / 300 to 3000 ppm, 5 /1 strokes.

What is the OSHA exposure limit for Cyclohexane? OSHA PEL TWA 300 ppm (1050 mg/m³); NIOSH REL TWA 300 ppm (1050 mg/m³); IDLH 1300 ppm [10%LEL] (NIOSH Pocket Guide).

Which pump reads Draeger Cyclohexane tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Cyclohexane tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.