Skip to main content
Draeger detector tubes · Ethylene glycol

Draeger Ethylene Glycol Detector Tubes

1 Draeger short-term detector tube for Ethylene glycol, measuring range 10 to 180 mg/m3. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 176); prices are live. Ships in 1–2 business days.

Every Draeger tube for Ethylene glycol

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8101351Draeger Ethylene Glycol 10 Detector Tubes, Box of 510 to 180 mg/m310approx. 7 minwhite → pinkBox of 5$129.11

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 176, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Ethylene glycol exposure limits

LimitValue
OSHA PELnone
NIOSH REL
NIOSH IDLHN.D.
CAS number107-21-1
FormulaHOCH₂CH₂OH
Other names1,2-Dihydroxyethane, 1,2-Ethanediol, Glycol, Glycol alcohol, Monoethylene glycol

Source: NIOSH Pocket Guide to Chemical Hazards, Ethylene glycol (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Clear, colorless, syrupy, odorless liquid. [antifreeze] [Note: A solid below 9°F.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Ethylene glycol tube questions

Which Draeger tubes measure Ethylene glycol? 8101351 (10 to 180 mg/m3).

What is the lowest range Draeger tube for Ethylene glycol? 8101351, 10 to 180 mg/m3, 10 strokes.

What is the OSHA exposure limit for Ethylene glycol? OSHA PEL none; NIOSH REL ; IDLH N.D. (NIOSH Pocket Guide).

Which pump reads Draeger Ethylene glycol tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Ethylene glycol tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337