Draeger Ethylene Oxide Detector Tubes
2 Draeger short-term detector tubes for Ethylene oxide, measuring ranges from 1 to 15 ppm up to 25 to 500 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 177–178); prices are live. Ships in 1–2 business days.
Every Draeger tube for Ethylene oxide
| Part number | Tube | Measuring range | Strokes (n) | Measuring time | Color change | Pack | Price | |
|---|---|---|---|---|---|---|---|---|
| 6728961 | Draeger Ethylene Oxide 1/a Detector Tubes, Box of 5 | 1 to 15 ppm | 20 | approx. 8 min | white → pink | Box of 5 | $135.30 | |
| 6728241 | Draeger Ethylene Oxide 25/a Detector Tubes, Box of 10 | 25 to 500 ppm | 30 | approx. 6 min | light yellow → turquoise green | Box of 10 | $111.41 |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 177–178, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.
Draeger MicroTubes for Ethylene oxide (X-act 7000)
| MicroTube | Measuring range | Price |
|---|---|---|
| Draeger Ethylene Oxide MicroTubes for X-act 7000 | 25-250 ppb; 0.25-10 ppm | $211.86 |
MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.
Ethylene oxide exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | [1910.1047] TWA 1 ppm 5 ppm [15-minute Excursion] |
| NIOSH REL | Ca TWA <0.1 ppm (0.18 mg/m³) C 5 ppm (9 mg/m³) [10-min/day] |
| NIOSH IDLH | Ca [800 ppm] |
| CAS number | 75-21-8 |
| Formula | C₂H₄O |
| Other names | Dimethylene oxide, 1,2-Epoxy ethane, Oxirane |
| Conversion | 1 ppm = 1.80 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Ethylene oxide (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless gas or liquid (below 51°F) with an ether-like odor.
Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.
Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.
Draeger Ethylene oxide tube questions
Which Draeger tubes measure Ethylene oxide? 6728961 (1 to 15 ppm), 6728241 (25 to 500 ppm).
What is the lowest range Draeger tube for Ethylene oxide? 6728961, 1 to 15 ppm, 20 strokes.
What is the OSHA exposure limit for Ethylene oxide? OSHA PEL [1910.1047] TWA 1 ppm 5 ppm [15-minute Excursion]; NIOSH REL Ca TWA <0.1 ppm (0.18 mg/m³) C 5 ppm (9 mg/m³) [10-min/day]; IDLH Ca [800 ppm] (NIOSH Pocket Guide).
Which pump reads Draeger Ethylene oxide tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.
Do Draeger Ethylene oxide tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).