Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
6728961Draeger Ethylene Oxide 1/a Detector Tubes, Box of 51 to 15 ppm20approx. 8 minwhite → pinkBox of 5$135.30
6728241Draeger Ethylene Oxide 25/a Detector Tubes, Box of 1025 to 500 ppm30approx. 6 minlight yellow → turquoise greenBox of 10$111.41

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 177–178, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Draeger MicroTubes for Ethylene oxide (X-act 7000)

MicroTubeMeasuring rangePrice
Draeger Ethylene Oxide MicroTubes for X-act 700025-250 ppb; 0.25-10 ppm$211.86

MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.

Ethylene oxide exposure limits

LimitValue
OSHA PEL[1910.1047] TWA 1 ppm 5 ppm [15-minute Excursion]
NIOSH RELCa TWA <0.1 ppm (0.18 mg/m³) C 5 ppm (9 mg/m³) [10-min/day]
NIOSH IDLHCa [800 ppm]
CAS number75-21-8
FormulaC₂H₄O
Other namesDimethylene oxide, 1,2-Epoxy ethane, Oxirane
Conversion1 ppm = 1.80 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Ethylene oxide (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless gas or liquid (below 51°F) with an ether-like odor.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Ethylene oxide tube questions

Which Draeger tubes measure Ethylene oxide? 6728961 (1 to 15 ppm), 6728241 (25 to 500 ppm).

What is the lowest range Draeger tube for Ethylene oxide? 6728961, 1 to 15 ppm, 20 strokes.

What is the OSHA exposure limit for Ethylene oxide? OSHA PEL [1910.1047] TWA 1 ppm 5 ppm [15-minute Excursion]; NIOSH REL Ca TWA <0.1 ppm (0.18 mg/m³) C 5 ppm (9 mg/m³) [10-min/day]; IDLH Ca [800 ppm] (NIOSH Pocket Guide).

Which pump reads Draeger Ethylene oxide tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Ethylene oxide tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).