Skip to main content

Draeger Fluorine Detector Tubes

1 Draeger short-term detector tube for Fluorine, measuring range 0.1 to 2 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 180); prices are live. Ships in 1–2 business days.

Every Draeger tube for Fluorine

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8101491Draeger Fluorine 0.1/a Detector Tubes, Box of 100.1 to 2 ppm20approx. 5 minwhite → yellowBox of 10$156.21

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 180, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Fluorine exposure limits

LimitValue
OSHA PELTWA 0.1 ppm (0.2 mg/m³)
NIOSH RELTWA 0.1 ppm (0.2 mg/m³)
NIOSH IDLH25 ppm
CAS number7782-41-4
FormulaF₂
Other namesFluorine-19
Conversion1 ppm = 1.55 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Fluorine (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Pale-yellow to greenish gas with a pungent, irritating odor.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Fluorine tube questions

Which Draeger tubes measure Fluorine? 8101491 (0.1 to 2 ppm).

What is the lowest range Draeger tube for Fluorine? 8101491, 0.1 to 2 ppm, 20 strokes.

What is the OSHA exposure limit for Fluorine? OSHA PEL TWA 0.1 ppm (0.2 mg/m³); NIOSH REL TWA 0.1 ppm (0.2 mg/m³); IDLH 25 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Fluorine tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Fluorine tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.