Skip to main content

Draeger Methanol Detector Tubes

1 Draeger short-term detector tube for Methanol, measuring range 20 to 250 ppm / 200 to 5000 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 220); prices are live. Ships in 1–2 business days.

Every Draeger tube for Methanol

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8103801Draeger Methanol 20/a Detector Tubes, Box of 1020 to 250 ppm / 200 to 5000 ppm15 / 5approx. 6 min / 2 minyellow → mint greenBox of 10$117.73

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 220, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Methanol exposure limits

LimitValue
OSHA PELTWA 200 ppm (260 mg/m³)
NIOSH RELTWA 200 ppm (260 mg/m³) ST 250 ppm (325 mg/m³) [skin]
NIOSH IDLH6000 ppm
CAS number67-56-1
FormulaCH₃OH
Other namesCarbinol, Columbian spirits, Methanol, Pyroligneous spirit, Wood alcohol, Wood naphtha, Wood spirit
Conversion1 ppm = 1.31 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Methyl alcohol (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless liquid with a characteristic pungent odor.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Methanol tube questions

Which Draeger tubes measure Methanol? 8103801 (20 to 250 ppm / 200 to 5000 ppm).

What is the lowest range Draeger tube for Methanol? 8103801, 20 to 250 ppm / 200 to 5000 ppm, 15 / 5 strokes.

What is the OSHA exposure limit for Methanol? OSHA PEL TWA 200 ppm (260 mg/m³); NIOSH REL TWA 200 ppm (260 mg/m³) ST 250 ppm (325 mg/m³) [skin]; IDLH 6000 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Methanol tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Methanol tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337