Skip to main content
Draeger detector tubes · Methyl acrylate

Draeger Methyl Acrylate Detector Tubes

1 Draeger short-term detector tube for Methyl acrylate, measuring range 5 to 200 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 221); prices are live. Ships in 1–2 business days.

Every Draeger tube for Methyl acrylate

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
6728161Draeger Methyl Acrylate 5/a Detector Tubes, Box of 105 to 200 ppm20approx. 5 minyellow → blueBox of 10$127.61

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 221, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Methyl acrylate exposure limits

LimitValue
OSHA PELTWA 10 ppm (35 mg/m³) [skin]
NIOSH RELTWA 10 ppm (35 mg/m³) [skin]
NIOSH IDLH250 ppm
CAS number96-33-3
FormulaCH₂=CHCOOCH₃
Other namesMethoxycarbonylethylene, Methyl ester of acrylic acid, Methyl propenoate
Conversion1 ppm = 3.52 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Methyl acrylate (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless liquid with an acrid odor.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Methyl acrylate tube questions

Which Draeger tubes measure Methyl acrylate? 6728161 (5 to 200 ppm).

What is the lowest range Draeger tube for Methyl acrylate? 6728161, 5 to 200 ppm, 20 strokes.

What is the OSHA exposure limit for Methyl acrylate? OSHA PEL TWA 10 ppm (35 mg/m³) [skin]; NIOSH REL TWA 10 ppm (35 mg/m³) [skin]; IDLH 250 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Methyl acrylate tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Methyl acrylate tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.