Skip to main content
Draeger detector tubes · Nickel tetracarbonyl

Draeger Nickel Tetracarbonyl Detector Tubes

1 Draeger short-term detector tube for Nickel tetracarbonyl, measuring range 0.1 to 1 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 227); prices are live. Ships in 1–2 business days.

Every Draeger tube for Nickel tetracarbonyl

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
CH19501Draeger Nickel Tetracarbonyl 0.1/a Detector Tubes, Box of 90.1 to 1 ppm20approx. 5 minyellow → pinkBox of 9$188.22

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 227, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Nickel tetracarbonyl exposure limits

LimitValue
OSHA PELTWA 0.001 ppm (0.007 mg/m³)
NIOSH RELCa TWA 0.001 ppm (0.007 mg/m³)
NIOSH IDLHCa [2 ppm]
CAS number13463-39-3
FormulaNi(CO)₄
Other namesNickel tetracarbonyl, Tetracarbonyl nickel
Conversion1 ppm = 6.98 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Nickel carbonyl (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless to yellow liquid with a musty odor. [Note: A gas above 110°F.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Nickel tetracarbonyl tube questions

Which Draeger tubes measure Nickel tetracarbonyl? CH19501 (0.1 to 1 ppm).

What is the lowest range Draeger tube for Nickel tetracarbonyl? CH19501, 0.1 to 1 ppm, 20 strokes.

What is the OSHA exposure limit for Nickel tetracarbonyl? OSHA PEL TWA 0.001 ppm (0.007 mg/m³); NIOSH REL Ca TWA 0.001 ppm (0.007 mg/m³); IDLH Ca [2 ppm] (NIOSH Pocket Guide).

Which pump reads Draeger Nickel tetracarbonyl tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Nickel tetracarbonyl tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.