Skip to main content
Draeger detector tubes · Nitric acid

Draeger Nitric Acid Detector Tubes

1 Draeger short-term detector tube for Nitric acid, measuring range 5 to 50 ppm / 1 to 15 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 228); prices are live. Ships in 1–2 business days.

Every Draeger tube for Nitric acid

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
6728311Draeger Nitric Acid 1/a Detector Tubes, Box of 105 to 50 ppm / 1 to 15 ppm10 / 20approx. 2 min / approx. 4 minblue → yellowBox of 10$142.42

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 228, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Nitric acid exposure limits

LimitValue
OSHA PELTWA 2 ppm (5 mg/m³)
NIOSH RELTWA 2 ppm (5 mg/m³) ST 4 ppm (10 mg/m³)
NIOSH IDLH25 ppm
CAS number7697-37-2
FormulaHNO₃
Other namesAqua fortis, Engravers acid, Hydrogen nitrate, Red fuming nitric acid, RFNA, White fuming nitric acid (WFNA)
Conversion1 ppm = 2.58 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Nitric acid (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless, yellow, or red, fuming liquid with an acrid, suffocating odor. [Note: Often used in an aqueous solution. Fuming nitric acid is concentrated nitric acid that contains dissolved nitrogen dioxide.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Nitric acid tube questions

Which Draeger tubes measure Nitric acid? 6728311 (5 to 50 ppm / 1 to 15 ppm).

What is the lowest range Draeger tube for Nitric acid? 6728311, 5 to 50 ppm / 1 to 15 ppm, 10 / 20 strokes.

What is the OSHA exposure limit for Nitric acid? OSHA PEL TWA 2 ppm (5 mg/m³); NIOSH REL TWA 2 ppm (5 mg/m³) ST 4 ppm (10 mg/m³); IDLH 25 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Nitric acid tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Nitric acid tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.