3 Draeger short-term detector tubes for Nitrogen dioxide, measuring ranges from 5 to 100 ppm / 2 to 50 ppm up to 10-200 ppm in 1 h (down to 1.3-25 ppm in 8 h). Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 229–230); prices are live. Ships in 1–2 business days.
Every Draeger tube for Nitrogen dioxide
| Part number | Tube | Measuring range | Strokes (n) | Measuring time | Color change | Pack | Price | |
|---|---|---|---|---|---|---|---|---|
| 6719101 | Draeger Nitrogen Dioxide 2/c Detector Tubes, Box of 10 | 5 to 100 ppm / 2 to 50 ppm | 5 / 10 | approx. 1 min / approx. 2 min | yellow-green → blue-gray | Box of 10 | $134.72 | |
| 8103631 | Draeger Nitrogen Dioxide 0.1/a Detector Tubes, Box of 10 | 5 to 30 ppm / 0.1 to 5 ppm | 1 /5 | approx. 15 s / approx. 75 s | gray-green → blue-gray | Box of 10 | $133.91 | |
| 8101111 | Draeger Nitrogen Dioxide 10/a-D Detector Tubes, Box of 10 | 10-200 ppm in 1 h (down to 1.3-25 ppm in 8 h) | Box of 10 | $148.97 |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 229–230, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.
Draeger MicroTubes for Nitrogen dioxide (X-act 7000)
| MicroTube | Measuring range | Price |
|---|---|---|
| Draeger Nitrogen Dioxide MicroTube for X-act 7000, 0.25-25 ppm | 0.25-25 ppm | $117.81 |
MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.
Nitrogen dioxide exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | C 5 ppm (9 mg/m³) |
| NIOSH REL | ST 1 ppm (1.8 mg/m³) |
| NIOSH IDLH | 13 ppm |
| CAS number | 10102-44-0 |
| Formula | NO₂ |
| Other names | Dinitrogen tetroxide, Nitrogen peroxide |
| Conversion | 1 ppm = 1.88 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Nitrogen dioxide (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Yellowish-brown liquid or reddish-brown gas (above 70°F) with a pungent, acrid odor. [Note: In solid form (below 15°F) it is found structurally as N₂O₂.]
Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.
Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.
Draeger Nitrogen dioxide tube questions
Which Draeger tubes measure Nitrogen dioxide? 6719101 (5 to 100 ppm / 2 to 50 ppm), 8103631 (5 to 30 ppm / 0.1 to 5 ppm), 8101111 (10-200 ppm in 1 h (down to 1.3-25 ppm in 8 h)).
What is the lowest range Draeger tube for Nitrogen dioxide? 6719101, 5 to 100 ppm / 2 to 50 ppm, 5 / 10 strokes.
What is the OSHA exposure limit for Nitrogen dioxide? OSHA PEL C 5 ppm (9 mg/m³); NIOSH REL ST 1 ppm (1.8 mg/m³); IDLH 13 ppm (NIOSH Pocket Guide).
Which pump reads Draeger Nitrogen dioxide tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.
Do Draeger Nitrogen dioxide tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).