Draeger Nitrogen Dioxide Detector Tubes
3 Draeger short-term detector tubes for Nitrogen dioxide, measuring ranges from 5 to 100 ppm / 2 to 50 ppm up to 10-200 ppm in 1 h (down to 1.3-25 ppm in 8 h). Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 229–230). Ships in 1–2 business days.
Every Draeger tube for Nitrogen dioxide
| Part number | Tube | Measuring range | Strokes (n) | Measuring time | Color change | Pack | Price | ||
|---|---|---|---|---|---|---|---|---|---|
![]() | 6719101 | Draeger Nitrogen Dioxide 2/c Detector Tubes, Box of 10 | 5 to 100 ppm / 2 to 50 ppm | 5 / 10 | approx. 1 min / approx. 2 min | yellow-green → blue-gray | Box of 10 | $134.72 | |
![]() | 8103631 | Draeger Nitrogen Dioxide 0.1/a Detector Tubes, Box of 10 | 5 to 30 ppm / 0.1 to 5 ppm | 1 /5 | approx. 15 s / approx. 75 s | gray-green → blue-gray | Box of 10 | $133.91 | |
![]() | 8101111 | Draeger Nitrogen Dioxide 10/a-D Detector Tubes, Box of 10 | 10-200 ppm in 1 h (down to 1.3-25 ppm in 8 h) | Box of 10 | $148.97 |
Two ranges on one tube? The range depends on the number of pump strokes. How pump strokes set the range on a Draeger tube.
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 229–230, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.
Draeger MicroTubes for Nitrogen dioxide (X-act 7000)
| MicroTube | Measuring range | Price |
|---|---|---|
| Draeger Nitrogen Dioxide MicroTube for X-act 7000, 0.25-25 ppm | 0.25-25 ppm | $117.81 |
MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.
Nitrogen dioxide exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | C 5 ppm (9 mg/m³) |
| NIOSH REL | ST 1 ppm (1.8 mg/m³) |
| NIOSH IDLH | 13 ppm |
| CAS number | 10102-44-0 |
| Formula | NO₂ |
| Other names | Dinitrogen tetroxide, Nitrogen peroxide |
| Conversion | 1 ppm = 1.88 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Nitrogen dioxide (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Yellowish-brown liquid or reddish-brown gas (above 70°F) with a pungent, acrid odor. [Note: In solid form (below 15°F) it is found structurally as N₂O₂.]
Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.
Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.
Draeger Nitrogen dioxide tube questions
Which Draeger tubes measure Nitrogen dioxide? 6719101 (5 to 100 ppm / 2 to 50 ppm), 8103631 (5 to 30 ppm / 0.1 to 5 ppm), 8101111 (10-200 ppm in 1 h (down to 1.3-25 ppm in 8 h)).
What is the lowest range Draeger tube for Nitrogen dioxide? 6719101, 5 to 100 ppm / 2 to 50 ppm, 5 / 10 strokes.
What is the OSHA exposure limit for Nitrogen dioxide? OSHA PEL C 5 ppm (9 mg/m³); NIOSH REL ST 1 ppm (1.8 mg/m³); IDLH 13 ppm (NIOSH Pocket Guide).
Which pump reads Draeger Nitrogen dioxide tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.
Do Draeger Nitrogen dioxide tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.