Skip to main content
Draeger detector tubes · Nitrogen dioxide

Draeger Nitrogen Dioxide Detector Tubes

3 Draeger short-term detector tubes for Nitrogen dioxide, measuring ranges from 5 to 100 ppm / 2 to 50 ppm up to 10-200 ppm in 1 h (down to 1.3-25 ppm in 8 h). Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 229–230); prices are live. Ships in 1–2 business days.

Every Draeger tube for Nitrogen dioxide

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
6719101Draeger Nitrogen Dioxide 2/c Detector Tubes, Box of 105 to 100 ppm / 2 to 50 ppm5 / 10approx. 1 min / approx. 2 minyellow-green → blue-grayBox of 10$134.72
8103631Draeger Nitrogen Dioxide 0.1/a Detector Tubes, Box of 105 to 30 ppm / 0.1 to 5 ppm1 /5approx. 15 s / approx. 75 sgray-green → blue-grayBox of 10$133.91
8101111Draeger Nitrogen Dioxide 10/a-D Detector Tubes, Box of 1010-200 ppm in 1 h (down to 1.3-25 ppm in 8 h)Box of 10$148.97

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 229–230, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Draeger MicroTubes for Nitrogen dioxide (X-act 7000)

MicroTubeMeasuring rangePrice
Draeger Nitrogen Dioxide MicroTube for X-act 7000, 0.25-25 ppm0.25-25 ppm$117.81

MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.

Nitrogen dioxide exposure limits

LimitValue
OSHA PELC 5 ppm (9 mg/m³)
NIOSH RELST 1 ppm (1.8 mg/m³)
NIOSH IDLH13 ppm
CAS number10102-44-0
FormulaNO₂
Other namesDinitrogen tetroxide, Nitrogen peroxide
Conversion1 ppm = 1.88 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Nitrogen dioxide (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Yellowish-brown liquid or reddish-brown gas (above 70°F) with a pungent, acrid odor. [Note: In solid form (below 15°F) it is found structurally as N₂O₂.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Nitrogen dioxide tube questions

Which Draeger tubes measure Nitrogen dioxide? 6719101 (5 to 100 ppm / 2 to 50 ppm), 8103631 (5 to 30 ppm / 0.1 to 5 ppm), 8101111 (10-200 ppm in 1 h (down to 1.3-25 ppm in 8 h)).

What is the lowest range Draeger tube for Nitrogen dioxide? 6719101, 5 to 100 ppm / 2 to 50 ppm, 5 / 10 strokes.

What is the OSHA exposure limit for Nitrogen dioxide? OSHA PEL C 5 ppm (9 mg/m³); NIOSH REL ST 1 ppm (1.8 mg/m³); IDLH 13 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Nitrogen dioxide tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Nitrogen dioxide tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.