Skip to main content
Draeger detector tubes · Sulfuric acid

Draeger Sulfuric Acid Detector Tubes

1 Draeger short-term detector tube for Sulfuric acid, measuring range 1 to 5 mg/m3. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 262); prices are live. Ships in 1–2 business days.

Every Draeger tube for Sulfuric acid

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
6728781Draeger Sulfuric Acid 1/a Detector Tubes, Box of 91 to 5 mg/m3100approx. 100 minbrown → pink-purpleBox of 9$197.79

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 262, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Sulfuric acid exposure limits

LimitValue
OSHA PELTWA 1 mg/m³
NIOSH RELTWA 1 mg/m³
NIOSH IDLH15 mg/m³
CAS number7664-93-9
FormulaH₂SO₄
Other namesBattery acid, Hydrogen sulfate, Oil of vitriol, Sulfuric acid (aqueous)

Source: NIOSH Pocket Guide to Chemical Hazards, Sulfuric acid (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless to dark-brown, oily, odorless liquid. [Note: Pure compound is a solid below 51°F. Often used in an aqueous solution.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Sulfuric acid tube questions

Which Draeger tubes measure Sulfuric acid? 6728781 (1 to 5 mg/m3).

What is the lowest range Draeger tube for Sulfuric acid? 6728781, 1 to 5 mg/m3, 100 strokes.

What is the OSHA exposure limit for Sulfuric acid? OSHA PEL TWA 1 mg/m³; NIOSH REL TWA 1 mg/m³; IDLH 15 mg/m³ (NIOSH Pocket Guide).

Which pump reads Draeger Sulfuric acid tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Sulfuric acid tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.