Skip to main content
Draeger detector tubes · Sulfuryl fluoride

Draeger Sulfuryl Fluoride Detector Tubes

1 Draeger short-term detector tube for Sulfuryl fluoride, measuring range 1 to 5 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 263); prices are live. Ships in 1–2 business days.

Every Draeger tube for Sulfuryl fluoride

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8103471Draeger Sulfuryl Fluoride 1/a Detector Tubes, Box of 51 to 5 ppm6approx. 3 minlight blue → light pinkBox of 5$203.38

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 263, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Sulfuryl fluoride exposure limits

LimitValue
OSHA PELTWA 5 ppm (20 mg/m³)
NIOSH RELTWA 5 ppm (20 mg/m³) ST 10 ppm (40 mg/m³)
NIOSH IDLH200 ppm
CAS number2699-79-8
FormulaSO₂F₂
Other namesSulfur difluoride dioxide, Vikane®
Conversion1 ppm = 4.18 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Sulfuryl fluoride (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless, odorless gas. [insecticide/fumigant] [Note: Shipped as a liquefied compressed gas.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Sulfuryl fluoride tube questions

Which Draeger tubes measure Sulfuryl fluoride? 8103471 (1 to 5 ppm).

What is the lowest range Draeger tube for Sulfuryl fluoride? 8103471, 1 to 5 ppm, 6 strokes.

What is the OSHA exposure limit for Sulfuryl fluoride? OSHA PEL TWA 5 ppm (20 mg/m³); NIOSH REL TWA 5 ppm (20 mg/m³) ST 10 ppm (40 mg/m³); IDLH 200 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Sulfuryl fluoride tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Sulfuryl fluoride tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.