Skip to main content
Draeger detector tubes · Trichloroethylene

Draeger Trichloroethylene Detector Tubes

2 Draeger short-term detector tubes for Trichloroethylene, measuring ranges from 20 to 250 ppm / 2 to 50 ppm up to 50 to 500 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 271–272); prices are live. Ships in 1–2 business days.

Every Draeger tube for Trichloroethylene

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
6728541Draeger Trichloroethylene 2/a Detector Tubes, Box of 1020 to 250 ppm / 2 to 50 ppm3 /5approx. 1.5 min / approx. 2.5 minlight gray → orangeBox of 10$116.90
8101881Draeger Trichloroethylene 50/a Detector Tubes, Box of 1050 to 500 ppm5approx. 1.5 minlight gray → orangeBox of 10$116.61

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 271–272, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Trichloroethylene exposure limits

LimitValue
OSHA PELTWA 100 ppm C 200 ppm 300 ppm (5-minute maximum peak in any 2 hours)
NIOSH RELCa
NIOSH IDLHCa [1000 ppm]
CAS number79-01-6
FormulaClCH=CCl₂
Other namesEthylene trichloride, TCE, Trichloroethene, Trilene
Conversion1 ppm = 5.37 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Trichloroethylene (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless liquid (unless dyed blue) with a chloroform-like odor.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Trichloroethylene tube questions

Which Draeger tubes measure Trichloroethylene? 6728541 (20 to 250 ppm / 2 to 50 ppm), 8101881 (50 to 500 ppm).

What is the lowest range Draeger tube for Trichloroethylene? 6728541, 20 to 250 ppm / 2 to 50 ppm, 3 /5 strokes.

What is the OSHA exposure limit for Trichloroethylene? OSHA PEL TWA 100 ppm C 200 ppm 300 ppm (5-minute maximum peak in any 2 hours); NIOSH REL Ca; IDLH Ca [1000 ppm] (NIOSH Pocket Guide).

Which pump reads Draeger Trichloroethylene tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Trichloroethylene tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337