Skip to main content
Draeger detector tubes · Triethylamine

Draeger Triethylamine Detector Tubes

1 Draeger short-term detector tube for Triethylamine, measuring range 5 to 60 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 273); prices are live. Ships in 1–2 business days.

Every Draeger tube for Triethylamine

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
6718401Draeger Triethylamine 5/a Detector Tubes, Box of 105 to 60 ppm5approx. 3 minyellow → blueBox of 10$132.93

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 273, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Triethylamine exposure limits

LimitValue
OSHA PELTWA 25 ppm (100 mg/m³)
NIOSH REL
NIOSH IDLH200 ppm
CAS number121-44-8
Formula(C₂H₅)₃N
Other namesTEA
Conversion1 ppm = 4.14 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Triethylamine (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless liquid with a strong, ammonia-like odor.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Triethylamine tube questions

Which Draeger tubes measure Triethylamine? 6718401 (5 to 60 ppm).

What is the lowest range Draeger tube for Triethylamine? 6718401, 5 to 60 ppm, 5 strokes.

What is the OSHA exposure limit for Triethylamine? OSHA PEL TWA 25 ppm (100 mg/m³); NIOSH REL ; IDLH 200 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Triethylamine tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Triethylamine tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.