Skip to main content
Draeger detector tubes · Water vapor

Draeger Water Vapor Detector Tubes

6 Draeger short-term detector tubes for Water vapor, measuring ranges from 0.1 to 1.0 mg/L up to L. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 276–279); prices are live. Ships in 1–2 business days.

Every Draeger tube for Water vapor

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8101321Draeger Water Vapor 0.1/a Detector Tubes, Box of 100.1 to 1.0 mg/L3approx. 1.5 minyellow → blueBox of 10$128.03
CH23401Draeger Water Vapor 0.1 Detector Tubes, Box of 101 to 40 mg/L10approx. 2 minyellow → reddish brownBox of 10$122.81
8103031Draeger Water Vapor 3/a Detector Tubes, Box of 103.0 to 60 Ibs/mmcf3approx. 90 syellow → blueBox of 10$123.72
8101781Draeger Water Vapor 1/b Detector Tubes, Box of 1020 to 40 mg/L / 1 to 18 mg/L1 /2approx. 20 s / approx. 40 syellow → turquoise blueBox of 10$122.81
6728531Draeger Water Vapor 5/a-P Tubes for Aerotest, Box of 105 to 200 mg/m3approx. 25 min / 12.5 minyellow → reddish brownBox of 10$124.28
8103061Draeger Water Vapor 20/a-P Tubes for Aerotest, Box of 1020 to 250 mg H2O/m310 min / 5 min / 2.5 minyellow → reddish brownBox of 10$123.87

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 276–279, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Water vapor tube questions

Which Draeger tubes measure Water vapor? 8101321 (0.1 to 1.0 mg/L), CH23401 (1 to 40 mg/L), 8103031 (3.0 to 60 Ibs/mmcf), 8101781 (20 to 40 mg/L / 1 to 18 mg/L), 6728531 (5 to 200 mg/m3), 8103061 (20 to 250 mg H2O/m3).

What is the lowest range Draeger tube for Water vapor? 8101321, 0.1 to 1.0 mg/L, 3 strokes.

Which pump reads Draeger Water vapor tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Water vapor tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.