Guide · Electrical and lighting · ANSI/PLATO FL 1 ratings, lumens vs candela, runtime, IP codes, UL 913 and Class I Division 1

Bayshore Safety & Industrial Supplies Guide

Flashlight and work light ratings: lumens, runtime, IP codes and what intrinsically safe means? The six ANSI/PLATO FL 1 icons (light output, peak beam intensity, beam distance, runtime, impact, water resistance), why 1,000 lumens is not always brighter, the 10 percent runtime rule, IPX4 vs IPX7 vs IP67, UL 913 and Class I Division 1 and 2 markings, headlamps and hard hat lights, and the OSHA lighting levels

Since 2009 flashlight makers in the US have rated their lights to one standard, ANSI/PLATO FL 1, and print its icons on the package: light output in lumens (total light leaving the lens, measured 30 to 120 seconds after switch-on), peak beam intensity in candela (how concentrated the center of the beam is), beam distance in meters (where the beam falls to 0.25 lux, about full moonlight), runtime in hours (from switch-on until output falls to 10 percent of the initial value, which is why a light rated 8 hours can be dim for the last 5), impact resistance in meters (dropped six times onto concrete and still working), and water resistance as IPX4 (splash), IPX7 (1 meter for 30 minutes) or IPX8 (deeper, as stated); a second digit before the X rates dust (IP67 is dust-tight and 1 meter submersion). Lumens is the number people shop by and candela and beam distance decide how far it reaches: a 1,000 lumen flood lights a room and a 300 lumen spot with high candela reads a sign at 200 meters. Intrinsically safe is a different rating: a light designed so it cannot release enough electrical or thermal energy to ignite a flammable atmosphere, tested and listed by UL (UL 913) or another NRTL and marked with the Class, Division and Group it is approved for (Class I Division 1 Groups A to D is the common gas rating for refineries, tanks and confined spaces; Class II for dusts; Division 2 lights are for areas where the atmosphere is not normally present), and 1910.307 and NFPA 70 Article 500 require equipment in a classified location to be approved for it; a plain flashlight, however rugged, is not intrinsically safe, and a Division 2 light is not a Division 1 light. Headlamps and hard hat lights follow the same ratings with the hard hat makers’ clip and mount notes, and some are intrinsically safe. The OSHA lighting levels are in 1926.56 Table D-3 (5 foot-candles for general construction areas, 3 for excavations and waste areas, 10 for shops and indoor work, 30 for first aid stations and offices) and 1910.146 and 1910.178 for confined spaces and forklifts, which set what a work light has to deliver. The band lists the flashlights, headlamps, intrinsically safe lights and work lights we stock with the FL 1 figures and hazardous location markings the maker prints.

Bayshore Safety. Industrial safety and PPE supplier since 2017. · Current as of November 2026 · ANSI/PLATO FL 1-2019, Flashlight Basic Performance Standard (the six ratings and test methods; summarized); UL 913, Intrinsically Safe Apparatus for Use in Class I, II and III Division 1 Hazardous Locations, and NFPA 70 Article 500 (summarized); 29 CFR 1910.307 and 1926.56 Table D-3 (osha.gov); the Streamlight, Nightstick, Pelican, Energizer and Milwaukee product data on this site (lumens, candela, runtime, impact, IP rating, hazardous location listing as printed)

Why two lights with the same lumens are not the same light. Lumens is the total output; a wide reflector spreads it into a flood and a deep reflector or a TIR lens packs it into a beam that reaches. The FL 1 icons split the two so a buyer can read reach (candela, beam distance) separately from output (lumens), and the runtime icon ends at 10 percent, not at dark. The hazardous location marking is a separate world: it is about not making a spark, and it is printed on the light or it does not exist. The cards go through each icon, then the markings, then the OSHA levels.

Flashlight ratings, question by question

Definitions are ANSI/PLATO FL 1; hazardous location markings are UL 913 and NFPA 70; lighting levels are 1926.56.

What is a lumen, and what is candela?Lumens (the light output icon) is the total luminous flux leaving the flashlight, measured in an integrating sphere between 30 and 120 seconds after turn-on, so it is a near-startup figure before heat and battery sag. Candela (peak beam intensity) is the brightest point of the beam, which depends on how the reflector or lens focuses the lumens: two 500 lumen lights can be 2,000 and 20,000 candela. Beam distance (meters) is derived from candela: the distance at which the beam is 0.25 lux, the brightness of a full moon, roughly the square root of candela times two. Lumens tell you how much the light lights up close; candela and beam distance tell you how far it reaches. Flood lights, area lights and headlamps are bought on lumens; spotlights and search lights on candela.
How is runtime measured, and why does the light seem to die sooner?FL 1 runtime is the time from 30 seconds after switch-on until the output drops to 10 percent of the 30-second value, on the batteries the maker specifies, at the mode stated. A light rated 10 hours on high may hold full brightness for two hours and spend the rest dimming toward 10 percent; regulated lights hold output flat and then drop, and their runtime is closer to useful time. Makers list runtime per mode (high, medium, low, strobe), and cold weather and rechargeable cells change it. For a shift light, the useful figure is the mode you will run and how long it stays above the level the work needs.
What do the impact and water icons mean?Impact resistance in meters: the light, with batteries, is dropped six times from the stated height onto cured concrete in different orientations and must still work with no cracks or breaks; 1 meter is the baseline, 2 and 3 meters are common on duty lights. Water resistance: IPX4 is splash-resistant from any direction (rain); IPX7 is temporary immersion to 1 meter for 30 minutes; IPX8 is continuous immersion deeper than 1 meter for the time stated. When the maker tests dust as well, the X becomes a digit: IP67 is dust-tight (6) and IPX7 water; IP68 dust-tight and submersible as stated. A light used in rain needs IPX4; in a trench or on a boat IPX7; around grinding and sanding dust IP6X.
What does intrinsically safe mean?An intrinsically safe apparatus (UL 913; the concept comes from NFPA 70 Article 504) is one whose circuits cannot release enough electrical or thermal energy, in normal operation or under fault, to ignite a specific flammable mixture: current and voltage are limited, energy storage is limited, and surface temperatures are held under the ignition temperature of the gas group. The listing is specific: the light is marked with the Class (I gases and vapors, II dusts, III fibers), the Division (1: hazard present normally; 2: hazard present only under abnormal conditions), the gas or dust Groups (A acetylene, B hydrogen, C ethylene, D propane and most hydrocarbons; E, F, G for dusts) and a temperature code (T3, T4). 1910.307(b) and NFPA 70 Article 500 require equipment in a classified location to be approved for the class and group, and the hazardous location guide covers how an area is classified. The marking is on the light body and in the listing; a light described as safety rated, rugged or explosion-proof-style without the marking is not intrinsically safe.
Division 1 or Division 2, and what about explosion proof?A Class I Division 1 listing means the light is safe where the flammable atmosphere is expected to be present in normal operation (inside tanks, confined spaces with product, around open process); Division 2 means safe where the atmosphere appears only under abnormal conditions (leaks, upsets), a lower bar that allows non-incendive rather than intrinsically safe design. A Division 2 light is never carried into a Division 1 area. Explosion-proof is a different protection method (a housing that contains an internal explosion), used on fixed fixtures and some lanterns, also marked with Class and Division; a hand light is usually intrinsically safe rather than explosion proof. Zone markings (Zone 0, 1, 2 under the IEC system; ATEX in Europe) appear on some lights and the hazardous location guide maps them to Divisions.
Headlamps, hard hat lights and right-angle lightsHeadlamps and hard hat lights are rated the same way, with the mount the hard hat guide covers (clips to the brim, a strap, or a bracket into accessory slots; the hard hat makers list which attachments do not affect the hat’s rating); intrinsically safe headlamps exist for confined space and refinery crews. Right-angle (firefighter and industrial) lights clip to a lapel or a vest and keep hands free; penlights and inspection lights go in a pocket; area lights and lanterns (rated in lumens with a long runtime) light a work zone, and intrinsically safe area lights light a tank. Rechargeable (lithium-ion) versus alkaline or lithium primary cells is a battery question in the battery guide; intrinsically safe lights are often restricted by the listing to the cell type and brand the maker names, and swapping batteries in a classified area is prohibited by the listing on most.
What light levels does OSHA require?1926.56(a) Table D-3 (construction), minimum foot-candles: 5 for general construction area lighting; 3 for general construction areas, concrete placement, excavation and waste areas, access ways, active storage areas, loading platforms, refueling and field maintenance areas; 5 for indoor warehouses, corridors, hallways and exitways; 5 for tunnels and shafts and general underground work (10 at the heading during drilling, mucking and scaling); 10 for general construction plants and shops (batch plants, screening plants, mechanical and electrical equipment rooms, carpenter shops, rigging lofts, active storerooms, barracks, mess halls, indoor toilets and workrooms); 30 for first aid stations, infirmaries and offices. 1910.146 requires a permit space to have lighting adequate for work and exit; 1910.178(h) requires auxiliary directional lighting on a forklift where general lighting is under 2 lumens per square foot. A flashlight supplements these; it does not replace area lighting for a work zone.
What else is on the box?Modes (high, low, strobe, momentary), switch type (tail, side, twist), battery type and whether rechargeable (USB-C and docking charge), lens and body material (polycarbonate lens, aluminum or nylon body), beam type (spot, flood, dual), regulated output, lockout to prevent pocket activation, and certifications beyond FL 1 and UL 913: NFPA 1971 for firefighter helmets, MSHA approval for mine lights, and the hard hat makers’ attachment compatibility. The product page carries the maker’s full FL 1 line and any hazardous location marking.

In plain words

  • Lumens is total light; candela and beam distance are reach. Flood on lumens, spot on candela.
  • Runtime ends at 10 percent output, not at dark; read the mode you will use.
  • Impact in meters dropped onto concrete; IPX4 rain, IPX7 a meter underwater, IP67 adds dust-tight.
  • Intrinsically safe is a UL 913 listing marked Class, Division and Group on the light; nothing else counts.
  • Division 2 lights stay out of Division 1 areas; explosion-proof is a different method.
  • OSHA wants 5 foot-candles on a general construction area and 10 in a shop; the flashlight is the supplement.

Questions people ask

How many lumens is a good work flashlight?

The makers’ duty and work lights run 300 to 1,000 lumens; candela and beam distance decide how far it reaches, and runtime in the mode you use decides whether it lasts the shift.

What is the difference between lumens and candela?

Lumens is the total light output; candela is the intensity at the center of the beam, which sets beam distance.

What does IPX7 mean on a flashlight?

Temporary immersion to 1 meter for 30 minutes; IPX4 is splash-resistant; IP67 adds dust-tight.

What does intrinsically safe mean on a flashlight?

A UL 913 listing that the light cannot release enough energy to ignite a flammable atmosphere, marked with the Class, Division and Group it is approved for.

Can you use a Division 2 light in a Division 1 area?

No; Division 1 requires a Division 1 listing. The marking on the light governs.

How bright does OSHA require a construction site to be?

5 foot-candles for general construction areas and 10 for shops and plants under 1926.56 Table D-3; a flashlight supplements that.

The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.

Outfitting a jobsite or shop with cords, lights and batteries?Call (925) 215-7337 or email us the tools, the run lengths and the quantities and we will quote cords, GFCIs, lights and batteries by the case with the part numbers listed. We sell nationwide.
All electrical and lighting guides

© 2026 Bayshore Safety & Industrial Supplies, Inc. All rights reserved. This guide may not be copied or republished without written permission.

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.