Bayshore Safety & Industrial Supplies Guide
What is the OSHA PEL for lead, iron oxide fume, sodium hydroxide, formaldehyde, ethylene oxide, toluene and benzene? Table Z-1, Table Z-2, the substance standards and the NIOSH limits, substance by substance
A PEL is OSHA’s permissible exposure limit, the legal maximum airborne concentration a worker may be exposed to, written in 29 CFR 1910.1000 Tables Z-1 and Z-2 for most substances and in a standard of its own for a few. The figures asked about most: lead 50 µg/m³ as an 8-hour average with an action level of 30 µg/m³ (1910.1025); iron oxide fume 10 mg/m³ (Table Z-1); sodium hydroxide 2 mg/m³ (Table Z-1); formaldehyde 0.75 ppm with a 2 ppm 15-minute STEL (1910.1048); ethylene oxide 1 ppm with a 5 ppm 15-minute excursion limit (1910.1047); toluene 200 ppm with a 300 ppm ceiling and a 500 ppm 10-minute peak (Table Z-2); benzene 1 ppm with a 5 ppm STEL and a 0.5 ppm action level (1910.1028). NIOSH publishes its own, usually lower, limits beside each.
RKI Instruments 72-PAC-A Multi-Gas Detectors, GX-3R Pro 5-Gas MonitorRKI GX-3R Pro 5-gas monitor: LEL, O2, H2S, CO and a fifth toxic channel (SO2, NH3, NO2, HCN or PH3)This site’s exposure-limit guides explain what a PEL, REL, TLV, TWA, STEL and ceiling are and table the gases a four-gas or five-gas monitor reads. This page answers the substance-by-substance questions the bank asks that those pages do not: the PEL for lead, iron oxide (welding fume), caustic soda, formaldehyde, ethylene oxide, toluene and benzene, what “action level” and “excursion limit” mean, what the employer must do when the benzene PEL is exceeded, and how the 8-hour average is computed from the formula in 1910.1000(d). Every figure is from the current e-CFR text or the NIOSH Pocket Guide, and the instruments named are the ones that read a gas or vapor; lead, iron oxide and sodium hydroxide are particulates and are measured by air sampling and laboratory analysis, not by a direct-reading monitor.
The PEL for each substance, with the NIOSH limit beside it
Table Z-1 figures are 8-hour time-weighted averages unless marked (C) for ceiling. The substance standards set their own averaging and short-term limits.
29 CFR 1910.1025(b) and (c); 29 CFR 1910.1000 Table Z-1; NIOSH Pocket Guide, lead.
29 CFR 1910.1000 Table Z-1 (iron oxide fume; particulates not otherwise regulated); NIOSH Pocket Guide, iron oxide dust and fume.
29 CFR 1910.1000 Table Z-1; NIOSH Pocket Guide, sodium hydroxide.
29 CFR 1910.1048(b) and (c); 29 CFR 1910.1000 Table Z-1; NIOSH Pocket Guide, formaldehyde.
29 CFR 1910.1047(b) and (c); NIOSH Pocket Guide, ethylene oxide.
29 CFR 1910.1000 Table Z-2 (toluene, Z37.12-1967); NIOSH Pocket Guide, toluene.
29 CFR 1910.1028(b), (c), (d), (f) and (i); 29 CFR 1910.1000 Tables Z-1 and Z-2; NIOSH Pocket Guide, benzene.
29 CFR 1910.1028(i)(1) and (i)(2).
29 CFR 1910.1000 Table Z-1; NIOSH Pocket Guide, chlorine and ammonia; RKI Instruments GX-3R Pro Operator’s Manual, Table 3.
29 CFR 1910.1000; 1926.55; 1915.1000; NIOSH Pocket Guide (REL definitions).
29 CFR 1910.1000(d)(1) and (d)(2); Table Z-1 (C) notation; Table Z-2 (acceptable ceiling and maximum peak).
29 CFR 1910.1000(a) and (e) (current e-CFR, Nov 2026); NIOSH Pocket Guide (REL vs PEL).
Exposure limits in plain words
- PEL: OSHA’s legal limit for a substance in workplace air (29 CFR 1910.1000 Tables Z-1 and Z-2, or the substance’s own standard). Enforceable.
- TWA: the average over an 8-hour shift. Short peaks are allowed if the average stays under the limit; the formula in 1910.1000(d) adds up concentration × hours and divides by 8.
- STEL (or excursion limit): a 15-minute average that may not be exceeded at any time in the shift. Formaldehyde 2 ppm, ethylene oxide 5 ppm, benzene 5 ppm.
- Ceiling (C, TLV-C): never exceeded, even for a moment. Chlorine 1 ppm, toluene 300 ppm with a 500 ppm 10-minute peak allowed once.
- Action level: usually half the PEL (lead 30 µg/m³, formaldehyde 0.5 ppm, EtO 0.5 ppm, benzene 0.5 ppm). At or above it, monitoring, medical surveillance and training kick in even if the PEL is met.
- REL: NIOSH’s limit, often lower than OSHA’s and not itself enforceable; IDLH: NIOSH’s immediately-dangerous level, which sets the respirator class.
- Gases and vapors (formaldehyde, EtO, toluene, benzene, chlorine, ammonia) can be read on the spot by a sensor, tube or PID. Particulates (lead, iron oxide fume, sodium hydroxide) are measured by an air sampling pump and a laboratory.
OSHA PEL, NIOSH REL and IDLH for the substances asked about
| Substance | OSHA PEL | NIOSH REL | NIOSH IDLH | Where the OSHA limit is written | How it is measured |
|---|---|---|---|---|---|
| Lead, inorganic (as Pb) | 50 µg/m³ 8-hour TWA; action level 30 µg/m³; 400 ÷ hours for shifts over 8 h | 0.050 mg/m³ TWA | 100 mg/m³ as Pb | 1910.1025(c) | Air sampling pump and filter, laboratory |
| Iron oxide fume (as Fe) | 10 mg/m³ 8-hour TWA | 5 mg/m³ TWA | 2,500 mg/m³ as Fe | Table Z-1 | Air sampling, laboratory |
| Sodium hydroxide (caustic soda, lye) | 2 mg/m³ 8-hour TWA | C 2 mg/m³ | 10 mg/m³ | Table Z-1 | Air sampling, laboratory |
| Formaldehyde | 0.75 ppm 8-hour TWA; 2 ppm 15-min STEL; action level 0.5 ppm | Ca; 0.016 ppm TWA; C 0.1 ppm (15 min) | Ca [20 ppm] | 1910.1048(c) | Detector tube, electrochemical sensor, PID, badge |
| Ethylene oxide | 1 ppm 8-hour TWA; 5 ppm 15-min excursion limit; action level 0.5 ppm | Ca; under 0.1 ppm TWA; C 5 ppm (10 min/day) | Ca [800 ppm] | 1910.1047(c) | Badge, sampling tube, EtO analyzer |
| Toluene | 200 ppm 8-hour TWA; 300 ppm ceiling; 500 ppm 10-min peak | 100 ppm TWA; 150 ppm STEL | 500 ppm | Table Z-2 | PID, detector tube |
| Benzene | 1 ppm 8-hour TWA; 5 ppm 15-min STEL; action level 0.5 ppm | Ca; 0.1 ppm TWA; 1 ppm STEL | Ca [500 ppm] | 1910.1028(c) (Table Z-2 for excluded operations) | Benzene-specific PID or tube, lab sampling |
| Chlorine | C 1 ppm (3 mg/m³) | C 0.5 ppm (15 min) | 10 ppm | Table Z-1 | Electrochemical Cl2 sensor, detector tube |
| Ammonia | 50 ppm 8-hour TWA (35 mg/m³) | 25 ppm TWA; 35 ppm STEL | 300 ppm | Table Z-1 | Electrochemical NH3 sensor (RKI GX-3R Pro 0 to 400 ppm), detector tube |
| Carbon monoxide (for comparison) | 50 ppm 8-hour TWA | 35 ppm TWA; C 200 ppm | 1,200 ppm | Table Z-1 | Electrochemical CO sensor |
| Hydrogen sulfide (for comparison) | C 20 ppm; 50 ppm 10-min peak once | C 10 ppm (10 min) | 100 ppm | Table Z-2 | Electrochemical H2S sensor |
The action levels and short-term limits are from each substance standard’s paragraph (b) definitions and (c) limits.
Source: 29 CFR 1910.1000 Tables Z-1 and Z-2; 29 CFR 1910.1025, 1910.1028, 1910.1047 and 1910.1048 (current e-CFR, Nov 2026); NIOSH Pocket Guide to Chemical Hazards (REL, IDLH). Ca = NIOSH potential occupational carcinogen; C = ceiling.
Questions people ask
What is the PEL for lead?
50 µg/m³ averaged over 8 hours (29 CFR 1910.1025(c)), reduced by 400 ÷ hours worked for shifts longer than 8 hours. NIOSH’s REL is the same 0.050 mg/m³; the IDLH is 100 mg/m³.
What is the OSHA action level for lead exposure?
30 µg/m³ as an 8-hour average, measured without regard to respirator use (1910.1025(b)). At or above it, exposure monitoring, medical surveillance and training provisions of the lead standard apply.
What is the OSHA PEL for iron oxide exposure?
10 mg/m³ as an 8-hour TWA for iron oxide fume (Table Z-1). NIOSH’s REL is 5 mg/m³ and the IDLH 2,500 mg/m³ as Fe. It is the main constituent of carbon-steel welding fume.
What is the OSHA PEL for sodium hydroxide?
2 mg/m³ as an 8-hour TWA (Table Z-1). NIOSH treats the same 2 mg/m³ as a ceiling, and lists the IDLH at 10 mg/m³.
What is the maximum concentration of formaldehyde a worker may be exposed to over an 8-hour day?
0.75 ppm as an 8-hour TWA (1910.1048(c)(1)); the 15-minute STEL is 2 ppm and the action level 0.5 ppm. NIOSH: 0.016 ppm TWA, 0.1 ppm ceiling, IDLH 20 ppm, listed as a carcinogen.
What is the OSHA STEL for formaldehyde?
2 ppm as a 15-minute short-term exposure limit (1910.1048(c)(2)).
What is OSHA’s 8-hour permissible exposure limit for ethylene oxide?
1 ppm as an 8-hour TWA, with a 5 ppm excursion limit averaged over 15 minutes and an action level of 0.5 ppm (1910.1047). NIOSH: under 0.1 ppm TWA, 5 ppm ceiling for 10 minutes a day, IDLH 800 ppm, carcinogen.
What is the acceptable ppm limit for toluene in the workplace?
OSHA Table Z-2: 200 ppm 8-hour TWA, 300 ppm acceptable ceiling, 500 ppm maximum peak for 10 minutes once per shift. NIOSH: 100 ppm TWA, 150 ppm STEL; IDLH 500 ppm.
What must your employer do if the concentration of benzene exceeds the PEL?
Establish a regulated area limited to authorized persons, use engineering controls and work practices to bring exposure to or below the limits (and respirators where they fall short), and provide medical surveillance to employees at or above the action level 30 or more days a year or at or above the PELs 10 or more days a year (1910.1028(d), (f), (i)).
What does benzene medical surveillance include?
An initial exam before assignment: detailed occupational history, physical exam, and a complete blood count with differential, platelet count, hematocrit, hemoglobin, red cell count and indices, reviewed by a physician; more tests at the physician’s discretion (1910.1028(i)(2)).
What is the PEL of chlorine gas?
A ceiling of 1 ppm (3 mg/m³) in Table Z-1, never to be exceeded. NIOSH: 0.5 ppm 15-minute ceiling; IDLH 10 ppm.
What is the OSHA permissible exposure limit for ammonia in the air?
50 ppm (35 mg/m³) as an 8-hour TWA (Table Z-1). NIOSH: 25 ppm TWA and 35 ppm STEL; IDLH 300 ppm.
What does the term PEL stand for?
Permissible exposure limit, OSHA’s enforceable airborne limit under 29 CFR 1910.1000 and the substance standards. It is an occupational health term, not a medical one.
What is the PEL for hazmat exposure?
There is no single hazmat PEL; each substance has its own line in Table Z-1 or Z-2 or its own standard. The safety data sheet names the substance and the table gives the limit.
How is the threshold limit value ceiling (TLV-C) defined?
As a concentration that may not be exceeded at any time during the workday. OSHA marks its ceilings (C) in Table Z-1; Table Z-2 adds an acceptable maximum peak that may exceed the ceiling once for a stated number of minutes.
How do I calculate the TWA exposure?
E = (C1T1 + C2T2 + … + CnTn) ÷ 8, concentration times hours summed and divided by 8 (1910.1000(d)(1)). OSHA’s example: 2 h at 150 + 2 h at 75 + 4 h at 50 ppm = 81.25 ppm.
What are ACGIH standards?
The American Conference of Governmental Industrial Hygienists publishes threshold limit values (TLVs) and biological exposure indices; they are guidance, not law, and are often lower than OSHA’s PELs. The PEL vs REL vs TLV guide linked below covers who sets each.
Are PELs legally enforceable?
Yes. 1910.1000(a) requires that exposure to a Table Z-1 substance not exceed the listed limit, and each substance standard carries its own compliance duties. NIOSH RELs and ACGIH TLVs are not enforceable in themselves.
Related guides
PEL vs REL vs TLV vs WELWho sets each exposure limitWhat is TWA, STEL and ceiling?The three shapes of an exposure limitWhich gases are toxic or flammable at work?IDLH, PEL, REL and LEL for 17 gasesBenzene exposure limitsAnd how benzene is measuredChlorine exposure limitsOSHA, NIOSH and the ppm effectsAmmonia exposure limitsOSHA, NIOSH and the ppm effectsThe ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.
© 2026 Bayshore Safety & Industrial Supplies, Inc. All rights reserved. This guide may not be copied or republished without written permission.