Skip to main content
Home › Guides › Gas detection › OSHA PELs by substance
Guide · Gas detection · OSHA 1910.1000 Tables Z-1 and Z-2 · 1910.1025, 1910.1028, 1910.1047, 1910.1048 · NIOSH Pocket Guide

Bayshore Safety & Industrial Supplies Guide

What is the OSHA PEL for lead, iron oxide fume, sodium hydroxide, formaldehyde, ethylene oxide, toluene and benzene? Table Z-1, Table Z-2, the substance standards and the NIOSH limits, substance by substance

A PEL is OSHA’s permissible exposure limit, the legal maximum airborne concentration a worker may be exposed to, written in 29 CFR 1910.1000 Tables Z-1 and Z-2 for most substances and in a standard of its own for a few. The figures asked about most: lead 50 µg/m³ as an 8-hour average with an action level of 30 µg/m³ (1910.1025); iron oxide fume 10 mg/m³ (Table Z-1); sodium hydroxide 2 mg/m³ (Table Z-1); formaldehyde 0.75 ppm with a 2 ppm 15-minute STEL (1910.1048); ethylene oxide 1 ppm with a 5 ppm 15-minute excursion limit (1910.1047); toluene 200 ppm with a 300 ppm ceiling and a 500 ppm 10-minute peak (Table Z-2); benzene 1 ppm with a 5 ppm STEL and a 0.5 ppm action level (1910.1028). NIOSH publishes its own, usually lower, limits beside each.

Bayshore Safety. Industrial safety and PPE supplier since 2017. · Current as of November 2026 · 29 CFR 1910.1000 Air contaminants, Tables Z-1 and Z-2 and paragraph (d) computation formulae (current e-CFR); 29 CFR 1910.1025 Lead, 1910.1028 Benzene, 1910.1047 Ethylene oxide and 1910.1048 Formaldehyde (current e-CFR); NIOSH Pocket Guide to Chemical Hazards, entries for lead, iron oxide dust and fume, sodium hydroxide, formaldehyde, ethylene oxide, toluene, benzene, chlorine and ammonia (REL, IDLH, physical description)
RKI Instruments 72-PAC-A Multi-Gas Detectors, GX-3R Pro 5-Gas MonitorRKI Instruments 72-PAC-A Multi-Gas Detectors, GX-3R Pro 5-Gas MonitorRKI GX-3R Pro 5-gas monitor: LEL, O2, H2S, CO and a fifth toxic channel (SO2, NH3, NO2, HCN or PH3)

This site’s exposure-limit guides explain what a PEL, REL, TLV, TWA, STEL and ceiling are and table the gases a four-gas or five-gas monitor reads. This page answers the substance-by-substance questions the bank asks that those pages do not: the PEL for lead, iron oxide (welding fume), caustic soda, formaldehyde, ethylene oxide, toluene and benzene, what “action level” and “excursion limit” mean, what the employer must do when the benzene PEL is exceeded, and how the 8-hour average is computed from the formula in 1910.1000(d). Every figure is from the current e-CFR text or the NIOSH Pocket Guide, and the instruments named are the ones that read a gas or vapor; lead, iron oxide and sodium hydroxide are particulates and are measured by air sampling and laboratory analysis, not by a direct-reading monitor.

The PEL for each substance, with the NIOSH limit beside it

Table Z-1 figures are 8-hour time-weighted averages unless marked (C) for ceiling. The substance standards set their own averaging and short-term limits.

What is the PEL for lead, and what is the OSHA action level for lead?50 micrograms per cubic meter of air (50 µg/m³) averaged over an 8-hour period, under 1910.1025(c)(1); Table Z-1 lists lead, inorganic (as Pb) with a pointer to that standard. If an employee is exposed for more than 8 hours in a day the limit is reduced by the formula 400 ÷ hours worked. The action level is 30 µg/m³ as an 8-hour average, measured without regard to respirator use (1910.1025(b)); exposure at or above it triggers the standard’s exposure monitoring, medical surveillance and training provisions even when the PEL itself is not exceeded. The NIOSH Pocket Guide lists the REL at 0.050 mg/m³ (the same 50 µg/m³) and the IDLH at 100 mg/m³ as Pb, and notes the limits apply to other lead compounds as well. Lead is a particulate, measured by a personal air sampling pump and filter analyzed in a laboratory, not by a gas monitor.
29 CFR 1910.1025(b) and (c); 29 CFR 1910.1000 Table Z-1; NIOSH Pocket Guide, lead.
What is the OSHA PEL for iron oxide, and what does it mean for welding?Table Z-1 lists iron oxide fume (CAS 1309-37-1) at 10 mg/m³ as an 8-hour average; the NIOSH Pocket Guide gives the entry as iron oxide dust and fume (as Fe), with a REL of 5 mg/m³ and an IDLH of 2,500 mg/m³ as Fe. Iron oxide fume is the main constituent of the fume from welding, cutting and grinding carbon steel, so this is the number a welding fume exposure is usually compared against first, with the alloy metals (manganese, chromium, nickel) and their own lower limits checked beside it; welding fume as a whole has no single Table Z-1 line, and OSHA’s general rule for “particulates not otherwise regulated” is 15 mg/m³ total dust and 5 mg/m³ respirable. Like lead, iron oxide is measured by air sampling and laboratory analysis.
29 CFR 1910.1000 Table Z-1 (iron oxide fume; particulates not otherwise regulated); NIOSH Pocket Guide, iron oxide dust and fume.
What is the OSHA PEL for sodium hydroxide (caustic soda, lye)?Table Z-1 lists sodium hydroxide (CAS 1310-73-2) at 2 mg/m³ as an 8-hour average. The NIOSH Pocket Guide lists it under caustic soda, lye, soda lye and sodium hydrate with a REL that is a ceiling of 2 mg/m³ and an IDLH of 10 mg/m³, which means NIOSH treats the same figure as a never-exceed level rather than a shift average. Sodium hydroxide in air is a mist or dust from handling the solid or spraying the solution, so it too is measured by air sampling; the hazard it is known for, chemical burns to skin and eyes, is a contact hazard governed by the PPE rules rather than the PEL.
29 CFR 1910.1000 Table Z-1; NIOSH Pocket Guide, sodium hydroxide.
What is the maximum formaldehyde a worker may be exposed to over 8 hours, and what is the OSHA STEL for formaldehyde?0.75 parts per million as an 8-hour TWA, and 2 ppm as a 15-minute short-term exposure limit, both in 1910.1048(c); Table Z-1 points to that standard. The formaldehyde standard also sets an action level of 0.5 ppm as an 8-hour TWA, above which exposure monitoring and medical surveillance apply. NIOSH lists formaldehyde as a potential occupational carcinogen (Ca) with a REL of 0.016 ppm as a TWA and a ceiling of 0.1 ppm for 15 minutes, and an IDLH of 20 ppm; the Pocket Guide describes it as a nearly colorless gas with a pungent, suffocating odor, often used in water solution. Formaldehyde is a gas, read directly by a detector tube or an electrochemical formaldehyde sensor, or by a PID with the lamp energy to ionize it.
29 CFR 1910.1048(b) and (c); 29 CFR 1910.1000 Table Z-1; NIOSH Pocket Guide, formaldehyde.
What is OSHA’s 8-hour PEL for ethylene oxide?1 part per million as an 8-hour TWA, with an excursion limit of 5 ppm averaged over any 15-minute sampling period, in 1910.1047(c); the standard’s action level is 0.5 ppm as an 8-hour TWA. NIOSH treats ethylene oxide as a potential occupational carcinogen with a REL below 0.1 ppm as a TWA and a ceiling of 5 ppm for 10 minutes a day, and an IDLH of 800 ppm; the Pocket Guide describes it as a colorless gas with an ether-like odor. The word “excursion limit” in the EtO standard is OSHA’s term for what other standards call a STEL: a 15-minute average that may not be exceeded. Sterilizer and fumigation operations are where the exposure happens, and the measurement is by badge, sampling tube or an analyzer built for EtO.
29 CFR 1910.1047(b) and (c); NIOSH Pocket Guide, ethylene oxide.
What is the acceptable ppm limit for toluene in the workplace?Toluene is a Table Z-2 substance: 200 ppm as an 8-hour TWA, an acceptable ceiling of 300 ppm, and an acceptable maximum peak above the ceiling of 500 ppm for no more than 10 minutes in a shift. NIOSH’s REL is 100 ppm as a TWA with a 150 ppm STEL, and the IDLH is 500 ppm; the Pocket Guide describes toluene as a colorless liquid with a sweet, pungent, benzene-like odor. Toluene vapor is read by a photoionization detector (PID), which responds to it well, or by a detector tube; a catalytic LEL sensor also sees it as a combustible but only at concentrations far above the toxic limit (toluene’s LEL is 1.2 percent, 12,000 ppm, per the RKI chart on the LEL guide).
29 CFR 1910.1000 Table Z-2 (toluene, Z37.12-1967); NIOSH Pocket Guide, toluene.
What is the benzene PEL, and what must the employer do if the concentration exceeds it?Under 1910.1028(c) the PEL is 1 ppm as an 8-hour TWA and 5 ppm as a 15-minute STEL; the action level is 0.5 ppm as an 8-hour TWA. When the airborne concentration exceeds or can reasonably be expected to exceed either limit the employer must establish a regulated area limited to authorized persons (1910.1028(d)); institute engineering controls and work practices to bring exposure to or below the PELs, and where those are not sufficient use them to reach the lowest achievable level and supplement with respirators (1910.1028(f)); and make medical surveillance available to employees exposed at or above the action level 30 or more days a year or at or above the PELs 10 or more days a year (1910.1028(i)). Table Z-2 keeps the old limits (10 ppm TWA, 25 ppm ceiling, 50 ppm 10-minute peak) only for the operations the benzene standard excludes. NIOSH lists benzene as a carcinogen with a REL of 0.1 ppm TWA and 1 ppm STEL and an IDLH of 500 ppm.
29 CFR 1910.1028(b), (c), (d), (f) and (i); 29 CFR 1910.1000 Tables Z-1 and Z-2; NIOSH Pocket Guide, benzene.
What does the benzene medical surveillance include?The benzene standard spells it out in 1910.1028(i)(2): an initial examination before assignment with a detailed occupational history (past exposure to benzene or other blood toxins, family and personal history of blood disorders, kidney or liver dysfunction, medicines routinely taken, previous radiation exposure, marrow toxins outside work), a complete physical examination, and laboratory tests consisting of a complete blood count including a leukocyte count with differential, a quantitative platelet count, hematocrit, hemoglobin, red cell count and red cell indices (MCV, MCH, MCHC), with the results reviewed by the examining physician; additional tests at the physician’s discretion; and, for workers who wear respirators 30 or more days a year, attention to the cardiopulmonary system. All examinations are provided without cost to the employee and performed by or under a licensed physician.
29 CFR 1910.1028(i)(1) and (i)(2).
What is the PEL of chlorine gas and of ammonia?Chlorine is a ceiling in Table Z-1: (C) 1 ppm, 3 mg/m³, never to be exceeded; NIOSH’s REL is a 15-minute ceiling of 0.5 ppm and the IDLH is 10 ppm. Ammonia is an 8-hour average in Table Z-1 of 50 ppm (35 mg/m³); NIOSH’s REL is 25 ppm TWA with a 35 ppm STEL and the IDLH is 300 ppm. Both are gases read directly by an electrochemical sensor: RKI’s GX-3R Pro offers an ammonia channel reading 0 to 400 ppm with alarms preset at 25 and 35 ppm (the NIOSH figures) and the SC-04 single-gas clip in NH3 and other toxics; chlorine is read by a Cl2 sensor or a detector tube. The chlorine and ammonia guides linked below carry the full ppm effect tables.
29 CFR 1910.1000 Table Z-1; NIOSH Pocket Guide, chlorine and ammonia; RKI Instruments GX-3R Pro Operator’s Manual, Table 3.
What does PEL stand for, and is “PEL” a medical term?Permissible exposure limit, the Occupational Safety and Health Administration’s legal limit for an airborne contaminant, enforceable under 29 CFR 1910.1000 in general industry (1926.55 in construction and 1915.1000 in shipyards). It is an occupational health term, not a clinical one; the medical equivalent for a chemical in the body is a biological exposure index or a blood level, such as the blood lead level the lead standard uses for medical removal. The other acronyms a PEL is compared with: REL is the NIOSH exposure limit, guidance rather than law, TLV is the ACGIH threshold limit value, and “PEL” in a school or state-agency context (ISBE and the like) is an unrelated abbreviation. The exposure-limit guides linked below explain who sets each and which one governs.
29 CFR 1910.1000; 1926.55; 1915.1000; NIOSH Pocket Guide (REL definitions).
How is the 8-hour TWA computed, and how is a ceiling (TLV-C) defined?1910.1000(d)(1) gives the formula: E = (CaTa + CbTb + … + CnTn) ÷ 8, where C is the concentration during a period of time T in hours during which it stays constant, and E, the equivalent exposure for the shift, may not exceed the 8-hour TWA in the table. OSHA’s own worked example: two hours at 150 ppm, two hours at 75 ppm and four hours at 50 ppm give (2 × 150 + 2 × 75 + 4 × 50) ÷ 8 = 81.25 ppm, acceptable against a 100 ppm limit. For a mixture of substances with similar effects, 1910.1000(d)(2) sums each concentration divided by its own limit and the total may not exceed 1. A ceiling, marked (C) in Table Z-1 and called TLV-C by ACGIH, is a concentration that may not be exceeded at any time during the shift, and Table Z-2 adds an “acceptable maximum peak” that may exceed the ceiling for a stated number of minutes once; the STEL, 15-minute average, is the form the newer substance standards use.
29 CFR 1910.1000(d)(1) and (d)(2); Table Z-1 (C) notation; Table Z-2 (acceptable ceiling and maximum peak).
What are the new workplace exposure limits in 2026, and are PELs legally enforceable?OSHA’s PELs are enforceable: 1910.1000(a) requires that an employee’s exposure to any Table Z-1 substance not exceed the listed TWA, and the substance standards carry their own compliance, monitoring and medical provisions. The Table Z-1 figures themselves are largely the 1971 adoptions and have not been revised as a set, which is why NIOSH RELs and ACGIH TLVs are usually lower and why many programs adopt the lower number; the current e-CFR is the source for whether any individual limit has changed, and this page cites the e-CFR as of November 2026. State plans may set lower limits (Cal/OSHA’s Table AC-1 is the example on the West Coast). Any “new 2026 limits” claim should be checked against the e-CFR text, not a summary.
29 CFR 1910.1000(a) and (e) (current e-CFR, Nov 2026); NIOSH Pocket Guide (REL vs PEL).

Exposure limits in plain words

  • PEL: OSHA’s legal limit for a substance in workplace air (29 CFR 1910.1000 Tables Z-1 and Z-2, or the substance’s own standard). Enforceable.
  • TWA: the average over an 8-hour shift. Short peaks are allowed if the average stays under the limit; the formula in 1910.1000(d) adds up concentration × hours and divides by 8.
  • STEL (or excursion limit): a 15-minute average that may not be exceeded at any time in the shift. Formaldehyde 2 ppm, ethylene oxide 5 ppm, benzene 5 ppm.
  • Ceiling (C, TLV-C): never exceeded, even for a moment. Chlorine 1 ppm, toluene 300 ppm with a 500 ppm 10-minute peak allowed once.
  • Action level: usually half the PEL (lead 30 µg/m³, formaldehyde 0.5 ppm, EtO 0.5 ppm, benzene 0.5 ppm). At or above it, monitoring, medical surveillance and training kick in even if the PEL is met.
  • REL: NIOSH’s limit, often lower than OSHA’s and not itself enforceable; IDLH: NIOSH’s immediately-dangerous level, which sets the respirator class.
  • Gases and vapors (formaldehyde, EtO, toluene, benzene, chlorine, ammonia) can be read on the spot by a sensor, tube or PID. Particulates (lead, iron oxide fume, sodium hydroxide) are measured by an air sampling pump and a laboratory.
29 CFR 1910.1000 and Tables Z-1 and Z-2; 1910.1025; 1910.1028; 1910.1047; 1910.1048; NIOSH Pocket Guide to Chemical Hazards.
OSHA PEL, NIOSH REL and IDLH for the substances asked about
SubstanceOSHA PELNIOSH RELNIOSH IDLHWhere the OSHA limit is writtenHow it is measured
Lead, inorganic (as Pb)50 µg/m³ 8-hour TWA; action level 30 µg/m³; 400 ÷ hours for shifts over 8 h0.050 mg/m³ TWA100 mg/m³ as Pb1910.1025(c)Air sampling pump and filter, laboratory
Iron oxide fume (as Fe)10 mg/m³ 8-hour TWA5 mg/m³ TWA2,500 mg/m³ as FeTable Z-1Air sampling, laboratory
Sodium hydroxide (caustic soda, lye)2 mg/m³ 8-hour TWAC 2 mg/m³10 mg/m³Table Z-1Air sampling, laboratory
Formaldehyde0.75 ppm 8-hour TWA; 2 ppm 15-min STEL; action level 0.5 ppmCa; 0.016 ppm TWA; C 0.1 ppm (15 min)Ca [20 ppm]1910.1048(c)Detector tube, electrochemical sensor, PID, badge
Ethylene oxide1 ppm 8-hour TWA; 5 ppm 15-min excursion limit; action level 0.5 ppmCa; under 0.1 ppm TWA; C 5 ppm (10 min/day)Ca [800 ppm]1910.1047(c)Badge, sampling tube, EtO analyzer
Toluene200 ppm 8-hour TWA; 300 ppm ceiling; 500 ppm 10-min peak100 ppm TWA; 150 ppm STEL500 ppmTable Z-2PID, detector tube
Benzene1 ppm 8-hour TWA; 5 ppm 15-min STEL; action level 0.5 ppmCa; 0.1 ppm TWA; 1 ppm STELCa [500 ppm]1910.1028(c) (Table Z-2 for excluded operations)Benzene-specific PID or tube, lab sampling
ChlorineC 1 ppm (3 mg/m³)C 0.5 ppm (15 min)10 ppmTable Z-1Electrochemical Cl2 sensor, detector tube
Ammonia50 ppm 8-hour TWA (35 mg/m³)25 ppm TWA; 35 ppm STEL300 ppmTable Z-1Electrochemical NH3 sensor (RKI GX-3R Pro 0 to 400 ppm), detector tube
Carbon monoxide (for comparison)50 ppm 8-hour TWA35 ppm TWA; C 200 ppm1,200 ppmTable Z-1Electrochemical CO sensor
Hydrogen sulfide (for comparison)C 20 ppm; 50 ppm 10-min peak onceC 10 ppm (10 min)100 ppmTable Z-2Electrochemical H2S sensor

The action levels and short-term limits are from each substance standard’s paragraph (b) definitions and (c) limits.

Source: 29 CFR 1910.1000 Tables Z-1 and Z-2; 29 CFR 1910.1025, 1910.1028, 1910.1047 and 1910.1048 (current e-CFR, Nov 2026); NIOSH Pocket Guide to Chemical Hazards (REL, IDLH). Ca = NIOSH potential occupational carcinogen; C = ceiling.

Questions people ask

What is the PEL for lead?

50 µg/m³ averaged over 8 hours (29 CFR 1910.1025(c)), reduced by 400 ÷ hours worked for shifts longer than 8 hours. NIOSH’s REL is the same 0.050 mg/m³; the IDLH is 100 mg/m³.

What is the OSHA action level for lead exposure?

30 µg/m³ as an 8-hour average, measured without regard to respirator use (1910.1025(b)). At or above it, exposure monitoring, medical surveillance and training provisions of the lead standard apply.

What is the OSHA PEL for iron oxide exposure?

10 mg/m³ as an 8-hour TWA for iron oxide fume (Table Z-1). NIOSH’s REL is 5 mg/m³ and the IDLH 2,500 mg/m³ as Fe. It is the main constituent of carbon-steel welding fume.

What is the OSHA PEL for sodium hydroxide?

2 mg/m³ as an 8-hour TWA (Table Z-1). NIOSH treats the same 2 mg/m³ as a ceiling, and lists the IDLH at 10 mg/m³.

What is the maximum concentration of formaldehyde a worker may be exposed to over an 8-hour day?

0.75 ppm as an 8-hour TWA (1910.1048(c)(1)); the 15-minute STEL is 2 ppm and the action level 0.5 ppm. NIOSH: 0.016 ppm TWA, 0.1 ppm ceiling, IDLH 20 ppm, listed as a carcinogen.

What is the OSHA STEL for formaldehyde?

2 ppm as a 15-minute short-term exposure limit (1910.1048(c)(2)).

What is OSHA’s 8-hour permissible exposure limit for ethylene oxide?

1 ppm as an 8-hour TWA, with a 5 ppm excursion limit averaged over 15 minutes and an action level of 0.5 ppm (1910.1047). NIOSH: under 0.1 ppm TWA, 5 ppm ceiling for 10 minutes a day, IDLH 800 ppm, carcinogen.

What is the acceptable ppm limit for toluene in the workplace?

OSHA Table Z-2: 200 ppm 8-hour TWA, 300 ppm acceptable ceiling, 500 ppm maximum peak for 10 minutes once per shift. NIOSH: 100 ppm TWA, 150 ppm STEL; IDLH 500 ppm.

What must your employer do if the concentration of benzene exceeds the PEL?

Establish a regulated area limited to authorized persons, use engineering controls and work practices to bring exposure to or below the limits (and respirators where they fall short), and provide medical surveillance to employees at or above the action level 30 or more days a year or at or above the PELs 10 or more days a year (1910.1028(d), (f), (i)).

What does benzene medical surveillance include?

An initial exam before assignment: detailed occupational history, physical exam, and a complete blood count with differential, platelet count, hematocrit, hemoglobin, red cell count and indices, reviewed by a physician; more tests at the physician’s discretion (1910.1028(i)(2)).

What is the PEL of chlorine gas?

A ceiling of 1 ppm (3 mg/m³) in Table Z-1, never to be exceeded. NIOSH: 0.5 ppm 15-minute ceiling; IDLH 10 ppm.

What is the OSHA permissible exposure limit for ammonia in the air?

50 ppm (35 mg/m³) as an 8-hour TWA (Table Z-1). NIOSH: 25 ppm TWA and 35 ppm STEL; IDLH 300 ppm.

What does the term PEL stand for?

Permissible exposure limit, OSHA’s enforceable airborne limit under 29 CFR 1910.1000 and the substance standards. It is an occupational health term, not a medical one.

What is the PEL for hazmat exposure?

There is no single hazmat PEL; each substance has its own line in Table Z-1 or Z-2 or its own standard. The safety data sheet names the substance and the table gives the limit.

How is the threshold limit value ceiling (TLV-C) defined?

As a concentration that may not be exceeded at any time during the workday. OSHA marks its ceilings (C) in Table Z-1; Table Z-2 adds an acceptable maximum peak that may exceed the ceiling once for a stated number of minutes.

How do I calculate the TWA exposure?

E = (C1T1 + C2T2 + … + CnTn) ÷ 8, concentration times hours summed and divided by 8 (1910.1000(d)(1)). OSHA’s example: 2 h at 150 + 2 h at 75 + 4 h at 50 ppm = 81.25 ppm.

What are ACGIH standards?

The American Conference of Governmental Industrial Hygienists publishes threshold limit values (TLVs) and biological exposure indices; they are guidance, not law, and are often lower than OSHA’s PELs. The PEL vs REL vs TLV guide linked below covers who sets each.

Are PELs legally enforceable?

Yes. 1910.1000(a) requires that exposure to a Table Z-1 substance not exceed the listed limit, and each substance standard carries its own compliance duties. NIOSH RELs and ACGIH TLVs are not enforceable in themselves.

The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.

Need monitors matched to the gases on your permit?Call (925) 215-7337 or email us the gases in your hazard assessment and where people work, and we will quote the monitors, calibration gas and docks with the manufacturer figures listed. We service and calibrate portable gas instruments and sell nationwide.
Gas detection selector

© 2026 Bayshore Safety & Industrial Supplies, Inc. All rights reserved. This guide may not be copied or republished without written permission.

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.