Skip to main content
Home › Guides › PPE program and OSHA basics › Rubber, PVC and PU boot care
Guide · PPE program and OSHA basics · 1910.136, ASTM F2413 codes, PVC vs rubber vs polyurethane vs neoprene, chemical charts and the inspect, wash, dry, store routine

Bayshore Safety & Industrial Supplies Guide

Rubber, PVC and polyurethane work boots: which material for which chemical and temperature, what the ASTM F2413 label codes mean, how to wash, dry and store them so they last and when 1910.136 requires them? PVC for water, acids, caustics and manure, natural rubber for flexibility and cold, neoprene for oils and fats, polyurethane for light weight and cold flex, Purofort and Steplite, I/75 C/75 EH PR SD Mt and SR codes, the OSHA foot protection rule, cracking from heat and sun, drying inside out and insoles, and when to replace

OSHA 1910.136(a) requires protective footwear where there is a danger of foot injury from falling or rolling objects, objects piercing the sole, or electrical hazards, and (b) requires it to meet ASTM F2413 (the 2005, 2011 or 2017 edition) or be equally effective; 1910.132(d) hazard assessment decides where, and the wet, chemical and sanitation hazards (food plants, wash bays, concrete, agriculture, chemical handling, wastewater) are where the waterproof molded boot comes in. The materials: PVC (polyvinyl chloride; Dunlop Chesapeake, DuraPro, Flex 3, Servus CORE, Boss and Liberty PVC): the cheapest waterproof boot, resists water, most acids, caustics, salts, manure, detergents and alcohols, poor against ketones, aromatic and chlorinated solvents and most oils (the maker’s chemical chart), stiffens below about 0 °F and softens in heat, 1 to 2 pound per boot; polyblend and PVC-nitrile blends (Servus XTP, Dunlop Polyblend, PolyGoliath) add oil, fat and animal fat resistance for food processing and fueling; natural rubber (latex; Liberty DuraWear 1522, Tingley Sigma, Muck Chore, Servus Neoprene III and the vulcanized boots): flexible, grippy, comfortable, resists water, acids, caustics and alcohols, attacked by oils, fuels, grease and ozone (cracks in sunlight and near electric motors), and the latex is an allergen for some; neoprene (Tingley Pylon, XTRATUF, Muck): resists oils, fats, greases, many solvents and acids, flexible in cold, costs more; polyurethane (Dunlop Purofort, Tingley Steplite X, Dunlop Snugboot): a foamed PU that is 30 to 40 percent lighter than PVC, insulates (Purofort Thermo to -58 °F), stays flexible in cold, resists oils, fats, most chemicals and abrasion, costs the most and is cut by sharp objects more easily; nitrile rubber for the heaviest oil and fuel. The F2413 label inside the shaft reads ASTM F2413-18, then M or F and the size, then I/75 C/75 (impact 75 foot-pounds, compression 2,500 pounds) for the toe (steel, composite, aluminum or carbon), then the optional codes: Mt (metatarsal), Cd (conductive, for static dissipation in explosive atmospheres), EH (electrical hazard, the outsole withstands 18,000 volts at 60 Hz for a minute dry; not for live-line work), SD (static dissipative, 10 to 100 megohms, SD 10, 35 or 100), PR (puncture-resistant plate, 270 pounds), and since F3445 the SR for slip resistance; a boot without the I/75 C/75 line is a plain-toe boot and not protective footwear under 1910.136, even if it is the same shell (the plain-toe versions in the band are for wet work where there is no impact hazard). Care decides the life: rinse mud, manure, concrete, chemicals and salt off at the end of the shift (concrete and caustics attack rubber and PVC over days), wash with mild soap and water, never solvents or petroleum cleaners on rubber, dry at room temperature with the insole out, never on a heater, in a dryer, in a hot truck cab or in direct sun (heat and UV are the main cause of cracking in rubber and hardening in PVC), store upright in the shade, use a boot dryer on low air only, rotate two pairs for wet work, replace the insoles (the Dunlop footbeds) when they pack down, and retire the boot when the shell cracks, the toe cap is exposed, the tread is worn below the lugs, the sole separates or a chemical has swelled or softened it, because a crack in a chemical boot is a hole. Fit: molded boots run in whole sizes, are worn with a work sock, need a finger of room at the heel, and the insulated and steel-toe versions take a half size up; a boot that slips at the heel blisters and a boot that is tight at the toe cap bruises. The band lists the PVC, rubber, neoprene and polyurethane boots, overboots, waders, insoles and boot care items we stock with the toe, the F2413 codes and the height.

Bayshore Safety. Industrial safety and PPE supplier since 2017. · Current as of November 2026 · 29 CFR 1910.136, Foot protection, and 1910.132(d), hazard assessment (osha.gov); 1926.96 for construction; ASTM F2413 (performance requirements for protective footwear), ASTM F2892 (soft-toe protective footwear), ASTM F3445 (slip-resistant marking) and ASTM F2913 (astm.org); the Dunlop (Purofort, Chesapeake, DuraPro, Flex 3, PolyGoliath, Snugboot), Servus, Tingley (Pylon, Steplite, Sigma, Flite), Boss, Liberty DuraWear, Muck, XTRATUF and ONGUARD product data and chemical resistance charts on this site (material, toe, F2413 codes, height, temperature and care instructions as printed)

Why the boots cracked across the instep in a season. Rubber and PVC die from heat and sun, not from work: the boots dried on the heater, baked in the truck and sat in the sun by the hose, and the ozone from the shop motors finished them. The cards cover the OSHA rule and the label codes, the four materials against chemicals and temperature, the plain-toe question, washing and drying, storage, fit and when to replace.

Molded work boots, question by question

The rule is 1910.136; the codes are ASTM F2413; the chemical and temperature limits are the makers’ charts; the care steps are the makers’ instructions.

When does OSHA require protective footwear, and what does the F2413 label mean?1910.136(a): protective footwear where employees are exposed to foot injuries from falling or rolling objects, objects piercing the sole, or where the feet are exposed to electrical hazards; 1910.136(b): the footwear complies with ASTM F2413-05, -11 or -17 or is demonstrated equally effective; 1910.132(d) hazard assessment documents where; 1926.96 covers construction. The label (stitched or printed inside the shaft or on the tongue): line 1, ASTM F2413-18 (the edition); line 2, M or F for the gender last and the size; line 3, I/75 C/75 (impact at 75 foot-pounds, compression at 2,500 pounds, the only ratings since the 2005 edition dropped the 50 and 30 classes); line 4 and 5, the optional codes: Mt/75 metatarsal, Cd conductive, EH electrical hazard (withstands 18,000 V at 60 Hz for one minute with no current flow over 1 mA under dry conditions; a secondary protection, not for electrical work), SD static dissipative (SD 100, SD 35 or SD 10 for the megohm range), PR puncture resistant (a plate withstanding 270 pounds), and CS chain saw. ASTM F2892 is the soft-toe standard for EH, SD and PR without a safety toe (Servus 18822 CORE soft toe carries it). A boot with no F2413 line (a plain-toe wader or rain boot) is not protective footwear, and in a steel-toe area it does not count. The SR mark (ASTM F3445, 2021) means the boot met the F2913 slip test. Slip and SR are covered with the ice cleats guide.
PVC or polyblend?PVC (polyvinyl chloride with plasticizer, injection-molded in one piece): waterproof, the lowest price, holds up to water, mud, concrete splash, most acids (sulfuric, hydrochloric, phosphoric at the chart concentrations), caustics (sodium hydroxide, ammonia), salts, manure and urine, detergents and sanitizers, alcohols and glycols; attacked by ketones (acetone, MEK), esters, aromatic solvents (toluene, xylene), chlorinated solvents, gasoline and most oils and animal fats, which swell and soften it; the plasticizer leaches in heat and the boot hardens; it stiffens in cold below about 0 °F and is heavier than PU. The general-purpose wash bay, farm, concrete, wastewater and food plant boot (Dunlop Chesapeake, DuraPro, Flex 3, Economy and 8101100 white food boot; Servus CORE; Boss and Liberty PVC; Seattle Glove; PIP Oliver). Polyblend and PVC-nitrile (Servus XTP, Dunlop Polyblend, PolyGoliath, Boss Polyblend): PVC with nitrile rubber blended in, which adds resistance to oils, fats, greases and animal fats and keeps flexibility in cold, for meat and poultry plants, dairies, fueling and shops; the chart decides, and the makers rate each compound against each chemical as excellent, good, fair or not recommended.
Natural rubber or neoprene?Natural rubber (vulcanized latex over a fabric liner, or dipped; Liberty DuraWear 1522 and 1510, Tingley Sigma and Flite, Muck Chore, Rocky and Servus rubber, Blundstone gumboots, Boss rubber): the most flexible and comfortable, excellent on wet floors, resists water, most acids, caustics, alcohols, ketones and some solvents better than PVC; attacked by oils, fuels, greases and fats (swells), degraded by ozone (electric motors, welding, sunlight) and UV, cracks at flex points when stored hot, and the latex protein is an allergen for latex-sensitive workers (a liner or a PU or PVC boot instead). Good in cold to about -20 °F in the insulated versions. Neoprene (polychloroprene; Tingley Pylon, XTRATUF Legacy, Muck and the Servus Neoprene III, often over a rubber or PU base): resists oils, fats, greases, petroleum, many acids and caustics and moderate solvents, stays flexible to about -40 °F, resists ozone and weather better than natural rubber, costs more; the commercial fishing, food processing, utility and petroleum boot. Nitrile rubber and nitrile-PVC are the heavy oil and fuel compounds (the chemical glove guides use the same chemistry).
Polyurethane: Purofort, Steplite and the insulated bootsFoamed polyurethane (Dunlop Purofort, Purofort+, Thermo+, RigPRO, FoodPRO, Snugboot; Tingley Steplite X): millions of closed air pockets in the shell make the boot 30 to 40 percent lighter than PVC and insulate it (Purofort Thermo+ to -58 °F with its liner; standard Purofort to -4 °F), it stays flexible in cold where PVC stiffens, resists oils, fats, greases, most acids, caustics, animal fats, manure, fertilizers and abrasion, wears longer on concrete than PVC, and the makers back it with longer wear claims; it is cut by glass and sharp steel more easily than PVC, is attacked by strong acids, ketones and some solvents at concentration, and costs two to three times a PVC boot. The food plant, cold storage, agriculture, wastewater and construction boot for anyone on their feet all shift. Hydrolysis: PU degrades slowly with moisture and heat over years of storage, so a PU boot kept in a hot, damp locker for five years can crumble even unworn; it is stored dry and cool and rotated.
How do I wash and dry them?The makers’ instructions (Dunlop, Tingley, Servus, Muck): rinse off mud, manure, concrete, fertilizer, salt and chemicals at the end of the shift with water, because concrete and caustics attack the shell over days and salt dries it; wash with mild soap or dish detergent and a soft brush, inside and out when the liner is wet; rinse; never use solvents, petroleum-based cleaners, bleach or abrasive pads on rubber or PU, and never tire shine or silicone sprays on a slip-resistant outsole; take the insole out and dry it separately; dry at room temperature standing upright or on a boot dryer on unheated or low air; never on a heater, radiator, in a clothes dryer, in front of a torpedo heater, in a hot truck cab or in direct sun, because heat and UV crack rubber and harden PVC and PU faster than anything the job does; stuff with newspaper for a wet liner; a disinfectant spray for the inside where the plant requires it (the food plant boot wash and sanitizer stations use a quat or chlorine dip at the label strength, and the boot is rinsed after); rotate two pairs so each dries fully between shifts. Rubber conditioner (glycerin-based) on natural rubber a few times a season keeps it from drying; nothing petroleum-based.
How should they be stored, and when replaced?Store upright (a boot rack or hanger, not folded over, which creases and cracks the instep and ankle), in the shade, at room temperature, away from electric motors, welding, ozone and sunlight, with the insoles out and the shell dry; in a locker with air, not a sealed bag while damp (mildew in the liner). Shelf life unworn: PVC and rubber lose plasticizer and crack over several years in heat; PU hydrolyzes; the makers say inspect a stored boot before issue. Replace when: the shell is cracked anywhere (a crack is a leak and a chemical path), the toe cap is exposed or dented, the tread is worn to the base between the lugs (slip resistance is the lugs), the sole separates from the upper, the shell has swelled, softened or gone sticky from a chemical, the liner is torn through, or the boot has taken a crush or impact (the toe cap is one-use after a real impact, as with a hard hat). Inspect weekly in chemical work; a daily look at the flex points takes seconds.
Fit, height, socks and accessoriesMolded boots come in whole sizes (some in half sizes) and are worn with a cushioned work sock (wool or synthetic; cotton holds sweat and blisters); a finger of room at the heel with the toes not touching the cap, and a steel or composite toe does not break in, so a toe that touches the cap on day one touches it every day; insulated and liner boots take a half size up, and the fit is checked with the insole and sock that will be worn. Height: 6 inch shoe and 10 inch ankle for wet floors, 14 to 17 inch knee boots for wash bays, agriculture, concrete and wading, 30 to 34 inch hip and chest waders for wastewater, dredging and utilities (the waders in the band). Overboots and overshoes (Tingley Workbrutes, Dunlop OnGuard Slicker, Neos Voyager, Servus SuperFit, ONGUARD) go over a leather work boot for wet work and come off dry; disposable boot covers for contamination control (the shoe and boot cover guide). Insoles (Dunlop Preform and Comfort footbeds) replace the packed-down originals and add cushion; metatarsal guards strap on where Mt is needed over a non-Mt boot; boot dryers, racks, sock liners and the chemical chart on the product page round it out.

In plain words

  • 1910.136: protective footwear where objects can fall, roll or pierce or where there is an electrical hazard, meeting ASTM F2413; a boot without the I/75 C/75 line is a plain-toe boot.
  • PVC for water, acids, caustics, manure and concrete at the lowest price; polyblend adds oil and fat resistance.
  • Natural rubber for flexibility and wet floors (not oils, not sunlight); neoprene for oils, fats and cold; polyurethane for light weight, cold flex, oils and long wear.
  • Rinse chemicals and concrete off daily, wash with mild soap, dry at room temperature with the insole out, never on heat or in the sun.
  • Store upright in the shade away from motors and sunlight; replace at the first crack, a worn tread, a dented toe or a swollen shell.
  • Whole sizes, a work sock, a finger at the heel; a half size up for insulated boots.

Questions people ask

Are PVC boots chemical resistant?

To water, most acids, caustics, salts, manure and detergents, yes; not to ketones, aromatic and chlorinated solvents, gasoline and most oils and fats, per the maker’s chart.

What is the difference between PVC and polyurethane boots?

Polyurethane is 30 to 40 percent lighter, insulates, stays flexible in cold, resists oils and wears longer; PVC is cheaper and tougher against cuts.

How do you keep rubber boots from cracking?

Rinse daily, wash with mild soap, dry at room temperature away from heaters and sun, store upright in the shade away from motors and ozone, and never use petroleum cleaners.

What do EH, SD and PR mean on a boot label?

Electrical hazard (outsole withstands 18,000 V dry), static dissipative (controlled resistance to ground) and puncture-resistant plate, under ASTM F2413.

Do plain-toe rubber boots meet OSHA?

Not as protective footwear under 1910.136; without the I/75 C/75 rating they are for wet and chemical work where there is no impact or compression hazard.

When should rubber boots be replaced?

At the first crack, a worn tread, an exposed or dented toe cap, sole separation, or a shell swollen or softened by a chemical.

The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.

Outfitting a wash bay, plant or farm crew with boots?Call (925) 215-7337 or email us the chemicals, the sizes and the toe requirement and we will quote PVC, rubber, neoprene or polyurethane boots with the part numbers listed. We sell nationwide.
All PPE program and OSHA basics guides

© 2026 Bayshore Safety & Industrial Supplies, Inc. All rights reserved. This guide may not be copied or republished without written permission.

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.