Description
The Draeger 6728371 is the Oil mist 10/a-P detector tube, measuring range 0.1 to 1 mg/m3 (handbook). Sold by the box of 10, 10 single-use tubes. Used in the Draeger Aerotest compressed-air test units. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Oil mist.
Draeger 6728371 specifications
| Item | Draeger data |
|---|---|
| Part number | 6728371 |
| Gas or substance | Oil mist |
| Tube type | 10/a-P |
| Measuring range | 0.1 to 1 mg/m3 |
| Color change | white → light beige or |
| Temperature | 10 to 30 °C |
| Humidity | As per the instructions for |
| Reaction principle | Oil + H2SO4 → beige/yellow reaction product |
| Pack | Box of 10 |
| Pump | Used in the Draeger Aerotest compressed-air test units |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook): The total concentrations of mineral and synthetic aerosols (mist) and oil vapors is indicated. Other higher-molecular organic compounds are also indicated, but with different sensitivities. Polyethylene glycol and silicone oils are not indicated.
Note (handbook): The oil tube is also suitable for analyzing the air in work areas in connection with a Dräger tube pump. The measuring time depends on the oil used. A list of tested oils is available at www.draeger.com/voice. Dräger CMSDräger Aerotest
Oil mist exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | TWA 5 mg/m³ |
| NIOSH REL | TWA 5 mg/m³ ST 10 mg/m³ |
| NIOSH IDLH | 2500 mg/m³ |
| CAS number | 8012-95-1 |
Source: NIOSH Pocket Guide to Chemical Hazards, Oil mist (mineral) (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Oil mist
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| 8103111 | Draeger 8103111 Oil Tubes for Aerotest (Oil PN, Navy), Box of 10 | 5 mg/m³ | Box of 10 |
| 6733031 | Draeger Oil Mist 1/a Detector Tubes, Box of 10 | 1 to 10 mg/m3 | Box of 10 |
Every Draeger tube for this gas, with live prices: Oil mist detector tubes.
Draeger 6728371 questions
What does the Draeger 6728371 measure? Oil mist, measuring range 0.1 to 1 mg/m3.
What is the color change on the 6728371? white → light beige or, read against the scale printed on the tube.
Do Draeger 6728371 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of 6728371? 10. Each tube is used once.
What temperature and humidity is the 6728371 rated for? Temperature 10 to 30 °C, humidity As per the instructions for (handbook).
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.