Skip to main content

Draeger Oil Mist Detector Tubes

3 Draeger short-term detector tubes for Oil mist, measuring ranges from 0.1 to 1 mg/m3 up to m³. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 235); prices are live. Ships in 1–2 business days.

Every Draeger tube for Oil mist

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
6728371Draeger Oil Mist 10/a-P Tubes for Aerotest, Box of 100.1 to 1 mg/m3white → light beige orBox of 10$128.05
6733031Draeger Oil Mist 1/a Detector Tubes, Box of 101 to 10 mg/m3100approx. 25 minwhite → brownBox of 10$124.28
8103111Draeger 8103111 Oil Tubes for Aerotest (Oil PN, Navy), Box of 105 mg/m³Box of 10$158.85

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 235, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Oil mist exposure limits

LimitValue
OSHA PELTWA 5 mg/m³
NIOSH RELTWA 5 mg/m³ ST 10 mg/m³
NIOSH IDLH2500 mg/m³
CAS number8012-95-1
Other namesHeavy mineral oil mist, Paraffin oil mist, White mineral oil mist

Source: NIOSH Pocket Guide to Chemical Hazards, Oil mist (mineral) (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless, oily liquid aerosol dispersed in air. [Note: Has an odor like burned lubricating oil.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Oil mist tube questions

Which Draeger tubes measure Oil mist? 6728371 (0.1 to 1 mg/m3), 6733031 (1 to 10 mg/m3), 8103111 (5 mg/m³).

What is the lowest range Draeger tube for Oil mist? 6728371, 0.1 to 1 mg/m3.

What is the OSHA exposure limit for Oil mist? OSHA PEL TWA 5 mg/m³; NIOSH REL TWA 5 mg/m³ ST 10 mg/m³; IDLH 2500 mg/m³ (NIOSH Pocket Guide).

Which pump reads Draeger Oil mist tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Oil mist tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.