Skip to main content

Draeger Hydrazine Detector Tubes

2 Draeger short-term detector tubes for Hydrazine, measuring ranges from 0.01 to 0.4 ppm / 0.5 to 6 ppm up to 0.1 to 5 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 188–189); prices are live. Ships in 1–2 business days.

Every Draeger tube for Hydrazine

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8103351Draeger Hydrazine 0.01/a Detector Tubes, Box of 100.01 to 0.4 ppm / 0.5 to 6 ppmsee tube /5approx. 20 to 30 min / approx. 1 minlight gray (white) → brown-grayBox of 10$137.71
CH31801Draeger Hydrazine 0.25/a Detector Tubes, Box of 100.25 to 10 ppm / 0.1 to 5 ppm10 / 20approx. 1 min / approx. 2 minyellow → blueBox of 10$139.18

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 188–189, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Hydrazine exposure limits

LimitValue
OSHA PELTWA 1 ppm (1.3 mg/m³) [skin]
NIOSH RELCa C 0.03 ppm (0.04 mg/m³) [2-hour]
NIOSH IDLHCa [50 ppm]
CAS number302-01-2
FormulaH₂NNH₂
Other namesDiamine, Hydrazine (anhydrous), Hydrazine base
Conversion1 ppm = 1.31 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Hydrazine (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless, fuming, oily liquid with an ammonia-like odor. [Note: A solid below 36°F.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Hydrazine tube questions

Which Draeger tubes measure Hydrazine? 8103351 (0.01 to 0.4 ppm / 0.5 to 6 ppm), CH31801 (0.25 to 10 ppm / 0.1 to 5 ppm).

What is the lowest range Draeger tube for Hydrazine? 8103351, 0.01 to 0.4 ppm / 0.5 to 6 ppm, see tube /5 strokes.

What is the OSHA exposure limit for Hydrazine? OSHA PEL TWA 1 ppm (1.3 mg/m³) [skin]; NIOSH REL Ca C 0.03 ppm (0.04 mg/m³) [2-hour]; IDLH Ca [50 ppm] (NIOSH Pocket Guide).

Which pump reads Draeger Hydrazine tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Hydrazine tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.