Description
The Draeger 8103351 is the Hydrazine 0.01/a detector tube, measuring range 0.01 to 0.4 ppm / 0.5 to 6 ppm, see tube /5 pump strokes, measuring time approx. 20 to 30 min / approx. 1 min (handbook, p. 188). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Hydrazine.
Draeger 8103351 specifications
| Item | Draeger data |
|---|---|
| Part number | 8103351 |
| Gas or substance | Hydrazine |
| Tube type | 0.01/a |
| Measuring range | 0.01 to 0.4 ppm / 0.5 to 6 ppm |
| Number of strokes (n) | see tube /5 |
| Measuring time | approx. 20 to 30 min / approx. 1 min |
| Standard deviation | ± 20 to 25 % |
| Color change | light gray (white) → brown-gray |
| Temperature | 10 to 30 °C |
| Humidity | 1 to 20 mg/L |
| Reaction principle | Hydrazine + silver salt → brown-gray reaction product |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 188, Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook, p. 188): 1,1-dimethylhydrazine and monomethylhydrazine are indicated with the same sensitivity (standard deviation ± 50 %). 5 ppm ammonia with 100 strokes gives a reading of approx. 0.01 ppm hydrazine. With 5 strokes, ammonia is not indicated, even at high concentrations. *The number of strokes for the small measuring range of the tube is normally n = 100. Due to manufacturing constraints, the number of strokes for the most sensitive measuring range can be max. 150 strokes. Please note the information on the number of strokes on the tubes.
Hydrazine exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | TWA 1 ppm (1.3 mg/m³) [skin] |
| NIOSH REL | Ca C 0.03 ppm (0.04 mg/m³) [2-hour] |
| NIOSH IDLH | Ca [50 ppm] |
| CAS number | 302-01-2 |
| Formula | H₂NNH₂ |
| Conversion | 1 ppm = 1.31 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Hydrazine (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Hydrazine
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| CH31801 | Draeger Hydrazine 0.25/a Detector Tubes, Box of 10 | 0.25 to 10 ppm / 0.1 to 5 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Hydrazine detector tubes.
Draeger 8103351 questions
What does the Draeger 8103351 measure? Hydrazine in air, measuring range 0.01 to 0.4 ppm / 0.5 to 6 ppm.
How many pump strokes does the 8103351 take? see tube /5 strokes (n) per the handbook, p. 188. Measuring time approx. 20 to 30 min / approx. 1 min.
Which pump does the 8103351 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
What is the color change on the 8103351? light gray (white) → brown-gray, read against the scale printed on the tube.
Do Draeger 8103351 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of 8103351? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.