Skip to main content

Draeger Ozone Detector Tubes

2 Draeger short-term detector tubes for Ozone, measuring ranges from 0.05 to 0.7 ppm up to 20 to 300 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 239–240); prices are live. Ships in 1–2 business days.

Every Draeger tube for Ozone

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
6733181Draeger Ozone 0.05/b Detector Tubes, Box of 100.05 to 0.7 ppm10approx. 3 minlight blue → whiteBox of 10$133.77
CH21001Draeger Ozone 10/a Detector Tubes, Box of 1020 to 300 ppm1approx. 20 sgreenish blue → yellowBox of 10$134.59

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 239–240, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Ozone exposure limits

LimitValue
OSHA PELTWA 0.1 ppm (0.2 mg/m³)
NIOSH RELC 0.1 ppm (0.2 mg/m³)
NIOSH IDLH5 ppm
CAS number10028-15-6
FormulaO₃
Other namesTriatomic oxygen
Conversion1 ppm = 1.96 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Ozone (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless to blue gas with a very pungent odor.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Ozone tube questions

Which Draeger tubes measure Ozone? 6733181 (0.05 to 0.7 ppm), CH21001 (20 to 300 ppm).

What is the lowest range Draeger tube for Ozone? 6733181, 0.05 to 0.7 ppm, 10 strokes.

What is the OSHA exposure limit for Ozone? OSHA PEL TWA 0.1 ppm (0.2 mg/m³); NIOSH REL C 0.1 ppm (0.2 mg/m³); IDLH 5 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Ozone tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Ozone tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.