Description
The Draeger 6733181 is the Ozone 0.05/b detector tube, measuring range 0.05 to 0.7 ppm, 10 pump strokes, measuring time approx. 3 min (handbook, p. 239). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Ozone.
Draeger 6733181 specifications
| Item | Draeger data |
|---|---|
| Part number | 6733181 |
| Gas or substance | Ozone |
| Tube type | 0.05/b |
| Measuring range | 0.05 to 0.7 ppm |
| Number of strokes (n) | 10 |
| Measuring time | approx. 3 min |
| Standard deviation | ± 10 to 15 % |
| Color change | light blue → white |
| Temperature | 0 to 40 °C |
| Humidity | 2 to 30 mg H2O/L |
| Reaction principle | O3 + indigo → isatin |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 239, Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook, p. 239): The indication is not affected by: 1 ppm sulfur dioxide 1 ppm chlorine 1 ppm nitrogen dioxide Higher concentrations of chlorine and nitrogen dioxide discolor the indicating layer a diffuse white to light gray.
Measuring range extension (handbook, p. 239): Measuring range 0.1 to 1.4 ppm where n = 5 strokes, multiply indicated scale value by 2. Measuring range 0.005 to 0.07 ppm where n = 100 strokes, divide indicated scale value by 10.
Ozone exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | TWA 0.1 ppm (0.2 mg/m³) |
| NIOSH REL | C 0.1 ppm (0.2 mg/m³) |
| NIOSH IDLH | 5 ppm |
| CAS number | 10028-15-6 |
| Formula | O₃ |
| Conversion | 1 ppm = 1.96 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Ozone (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Ozone
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| CH21001 | Draeger Ozone 10/a Detector Tubes, Box of 10 | 20 to 300 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Ozone detector tubes.
Draeger 6733181 questions
What does the Draeger 6733181 measure? Ozone in air, measuring range 0.05 to 0.7 ppm.
How many pump strokes does the 6733181 take? 10 strokes (n) per the handbook, p. 239. Measuring time approx. 3 min.
Which pump does the 6733181 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
What is the color change on the 6733181? light blue → white, read against the scale printed on the tube.
Do Draeger 6733181 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of 6733181? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.