Skip to main content
Draeger detector tubes · Perchloroethylene

Draeger Perchloroethylene Detector Tubes

2 Draeger short-term detector tubes for Perchloroethylene, measuring ranges from 0.5 to 4 ppm / 0.1 to 1 ppm up to 2 to 40 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 242–243); prices are live. Ships in 1–2 business days.

Every Draeger tube for Perchloroethylene

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8101551Draeger Perchloroethylene 0.1/a Detector Tubes, Box of 100.5 to 4 ppm / 0.1 to 1 ppm3 /9approx. 3 min / approx. 9 minlight gray → blueBox of 10$328.02
8101501Draeger Perchloroethylene 2/a Detector Tubes, Box of 1020 to 300 ppm / 2 to 40 ppm1 /5approx. 30 s / approx. 3 minyellow → gray-blueBox of 10$109.91

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 242–243, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Draeger MicroTubes for Perchloroethylene (X-act 7000)

MicroTubeMeasuring rangePrice
Draeger Perchloroethylene MicroTube for X-act 7000, 1-500 ppm1-500 ppm$117.81

MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.

Perchloroethylene exposure limits

LimitValue
OSHA PELTWA 100 ppm C 200 ppm (for 5 minutes in any 3-hour period), with a maximum peak of 300 ppm
NIOSH RELCa Minimize workplace exposure concentrations.
NIOSH IDLHCa [150 ppm]
CAS number127-18-4
FormulaCl₂C=CCl₂
Other namesPerchlorethylene, Perchloroethylene, Perk, Tetrachlorethylene
Conversion1 ppm = 6.78 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Tetrachloroethylene (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless liquid with a mild, chloroform-like odor.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Perchloroethylene tube questions

Which Draeger tubes measure Perchloroethylene? 8101551 (0.5 to 4 ppm / 0.1 to 1 ppm), 8101501 (20 to 300 ppm / 2 to 40 ppm).

What is the lowest range Draeger tube for Perchloroethylene? 8101551, 0.5 to 4 ppm / 0.1 to 1 ppm, 3 /9 strokes.

What is the OSHA exposure limit for Perchloroethylene? OSHA PEL TWA 100 ppm C 200 ppm (for 5 minutes in any 3-hour period), with a maximum peak of 300 ppm; NIOSH REL Ca Minimize workplace exposure concentrations.; IDLH Ca [150 ppm] (NIOSH Pocket Guide).

Which pump reads Draeger Perchloroethylene tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Perchloroethylene tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.