Skip to main content
Draeger

Draeger Perchloroethylene 2/a Detector Tubes, Box of 10

Item # 8101501
$109.91

The Draeger 8101501 is the Perchloroethylene 2/a detector tube, measuring range 20 to 300 ppm / 2 to 40 ppm, 1 /5 pump strokes, measuring time approx. 30 s / approx. 3 min (handbook, p. 243). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Perchloroethylene.

Draeger 8101501 specifications

ItemDraeger data
Part number8101501
Gas or substancePerchloroethylene
Tube type2/a
Measuring range20 to 300 ppm / 2 to 40 ppm
Number of strokes (n)1 /5
Measuring timeapprox. 30 s / approx. 3 min
Standard deviation± 15 to 20 %
Color changeyellow → gray-blue
Temperature15 to 30 °C
Humidityless than 25 mg H2O/L
Reaction principlea) CCl2=CCl2 + MnO4– → Cl2 b) Cl2 + diphenylbenzidine → gray-blue reaction product At higher concentrations, a reddish zone may occur at the begin- ning of the indicating layer.
PackBox of 10
PumpRead on a Draeger accuro or X-act 5000 tube pump

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 243, Dräger Safety AG & Co. KGaA.

Cross-sensitivity (handbook, p. 243): Other chlorinated hydrocarbons, free halogens, and halogen hydracids are also indicated. Gasoline vapors cause the reading to be shortened if the following concentrations are exceeded: 50 ppm for 5 strokes or 500 ppm for 1 stroke.

Perchloroethylene exposure limits

LimitValue
OSHA PELTWA 100 ppm C 200 ppm (for 5 minutes in any 3-hour period), with a maximum peak of 300 ppm
NIOSH RELCa Minimize workplace exposure concentrations.
NIOSH IDLHCa [150 ppm]
CAS number127-18-4
FormulaCl₂C=CCl₂
Conversion1 ppm = 6.78 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Tetrachloroethylene (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.

Other Draeger tubes for Perchloroethylene

Part numberTubeMeasuring rangePack
8101551Draeger Perchloroethylene 0.1/a Detector Tubes, Box of 100.5 to 4 ppm / 0.1 to 1 ppmBox of 10

Every Draeger tube for this gas, with live prices: Perchloroethylene detector tubes.

Draeger 8101501 questions

What does the Draeger 8101501 measure? Perchloroethylene in air, measuring range 20 to 300 ppm / 2 to 40 ppm.

How many pump strokes does the 8101501 take? 1 /5 strokes (n) per the handbook, p. 243. Measuring time approx. 30 s / approx. 3 min.

Which pump does the 8101501 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.

What is the color change on the 8101501? yellow → gray-blue, read against the scale printed on the tube.

Do Draeger 8101501 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How many tubes are in a box of 8101501? 10. Each tube is used once.

Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.

Usually ships in 1–2 business days; delivery in 3–7 business days.

Adding to cart… The item has been added
Sold by the Box
Specifications
Gases DetectedPerchloroethylene
Measuring Range20 to 300 ppm / 2 to 40 ppm
StyleShort-term detector tube
Capacity10 tubes per box
Pump Strokes1 /5
Measuring Timeapprox. 30 s / approx. 3 min
Tube Type2/a
Shipping & returns

In-stock orders: 1–2 business days to process, then 2–5 business days by ground (3–7 in all); regular rates apply and Contractor Direct orders ship free. Most items can be returned within 30 days in new, resalable condition; respirators, filters and other hygiene items are final sale. Shipping policy · Returns policy

Draeger Perchloroethylene 2/a Detector Tubes, Box of 10$109.91

More Draeger and other brands in this category

Reviews

No reviews yet. Used this on the job? Tell other crews how it held up.

Write a review ›
How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.