Skip to main content

Draeger Toluene Detector Tubes

3 Draeger short-term detector tubes for Toluene, measuring ranges from 50 to 300 ppm / 5 to 80 ppm up to 100 to 1800 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 266–268); prices are live. Ships in 1–2 business days.

Every Draeger tube for Toluene

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8101661Draeger Toluene 5/b Detector Tubes, Box of 1050 to 300 ppm / 5 to 80 ppm2 / 10approx. 2 min / approx. 10 minwhite → light brownBox of 10$127.47
8101701Draeger Toluene 50/a Detector Tubes, Box of 1050 to 400 ppm5approx. 1.5 minwhite → brownBox of 10$109.57
8101731Draeger Toluene 100/a Detector Tubes, Box of 10100 to 1800 ppm10approx. 1.5 minwhite → brown-purpleBox of 10$128.37

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 266–268, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Draeger MicroTubes for Toluene (X-act 7000)

MicroTubeMeasuring rangePrice
Draeger Toluene MicroTube for X-act 7000, 10-1000 ppm10-1000 ppm$117.81

MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.

Toluene exposure limits

LimitValue
OSHA PELTWA 200 ppm C 300 ppm 500 ppm (10-minute maximum peak)
NIOSH RELTWA 100 ppm (375 mg/m³) ST 150 ppm (560 mg/m³)
NIOSH IDLH500 ppm
CAS number108-88-3
FormulaC₆H₅CH₃
Other namesMethyl benzene, Methyl benzol, Phenyl methane, Toluol
Conversion1 ppm = 3.77 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Toluene (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless liquid with a sweet, pungent, benzene-like odor.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Toluene tube questions

Which Draeger tubes measure Toluene? 8101661 (50 to 300 ppm / 5 to 80 ppm), 8101701 (50 to 400 ppm), 8101731 (100 to 1800 ppm).

What is the lowest range Draeger tube for Toluene? 8101661, 50 to 300 ppm / 5 to 80 ppm, 2 / 10 strokes.

What is the OSHA exposure limit for Toluene? OSHA PEL TWA 200 ppm C 300 ppm 500 ppm (10-minute maximum peak); NIOSH REL TWA 100 ppm (375 mg/m³) ST 150 ppm (560 mg/m³); IDLH 500 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Toluene tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Toluene tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.