Description
The Draeger 8101731 is the Toluene 100/a detector tube, measuring range 100 to 1800 ppm, 10 pump strokes, measuring time approx. 1.5 min (handbook, p. 268). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Toluene.
Draeger 8101731 specifications
| Item | Draeger data |
|---|---|
| Part number | 8101731 |
| Gas or substance | Toluene |
| Tube type | 100/a |
| Measuring range | 100 to 1800 ppm |
| Number of strokes (n) | 10 |
| Measuring time | approx. 1.5 min |
| Standard deviation | ± 10 to 15 % |
| Color change | white → brown-purple |
| Temperature | 0 to 40 °C |
| Humidity | less than 30 mg H2O/L |
| Reaction principle | Toluene + SeO2 + H2SO4 → brown-purple reaction product |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 268, Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook, p. 268): Xylenes are also indicated with roughly the same sensitivity, but with a violet-blue color. Benzene colors the entire indicating layer a diffuse yellow-brown. Gasoline hydrocarbons color the entire indicating layer a diffuse reddish-brown. Methanol, ethanol, acetone, and ethyl acetate have no effect within their OEL ranges.
Toluene exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | TWA 200 ppm C 300 ppm 500 ppm (10-minute maximum peak) |
| NIOSH REL | TWA 100 ppm (375 mg/m³) ST 150 ppm (560 mg/m³) |
| NIOSH IDLH | 500 ppm |
| CAS number | 108-88-3 |
| Formula | C₆H₅CH₃ |
| Conversion | 1 ppm = 3.77 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Toluene (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Toluene
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| 8101661 | Draeger Toluene 5/b Detector Tubes, Box of 10 | 50 to 300 ppm / 5 to 80 ppm | Box of 10 |
| 8101701 | Draeger Toluene 50/a Detector Tubes, Box of 10 | 50 to 400 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Toluene detector tubes.
Draeger 8101731 questions
What does the Draeger 8101731 measure? Toluene in air, measuring range 100 to 1800 ppm.
How many pump strokes does the 8101731 take? 10 strokes (n) per the handbook, p. 268. Measuring time approx. 1.5 min.
Which pump does the 8101731 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
What is the color change on the 8101731? white → brown-purple, read against the scale printed on the tube.
Do Draeger 8101731 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of 8101731? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.