Skip to main content
Home › Guides › Hand protection › Glove standards list
Guide · Hand protection · ANSI/ISEA 105 · 138 · EN 388 · 407 · 511 · ISO 374 · ASTM D6319 · D6978 · D120 · F696 · F1060 · 21 CFR

Bayshore Safety & Industrial Supplies Guide

What are the ASTM, ANSI/ISEA and EN standards for gloves? Every standard printed on a glove, in one list, with what each one tests

Fifteen or so standards account for nearly every mark on the glove pages of this site, and each one tests one thing. ANSI/ISEA 105 is the American work-glove standard: cut (A1 to A9), abrasion (0 to 6), puncture (0 to 5), needle-stick puncture, contact heat (1 to 5), flame, conductive heat and vibration, each a separate level. ANSI/ISEA 138 rates back-of-hand impact (1 to 3). EN 388 is the European mechanical standard whose four digits and two letters (abrasion, blade cut, tear, puncture, ISO cut, impact) appear beside the ANSI levels on most knit gloves; EN 407 rates heat and flame in six digits, EN 511 cold in three, EN ISO 374-1 chemicals by type (A, B, C) and the letters A to T, EN 374-5 bacteria, fungi and viruses, EN 16350 electrostatic dissipation. The ASTM standards are material and product specifications: D6319 nitrile examination gloves, D3578 latex examination gloves, D5250 vinyl examination gloves, D3577 rubber surgical gloves, D6978 permeation by chemotherapy drugs, D120 rubber insulating gloves (the voltage classes 00 to 4), F696 leather protectors for insulating gloves, F1060 conductive and contact heat (the test ANSI/ISEA 105’s heat level uses), F739 chemical permeation and F1790 cut (the test methods behind the ratings). The federal rules are different in kind: 21 CFR Part 177 is a food-contact material listing, 21 CFR 800.20 the FDA leak-test sampling plan for medical gloves, and 29 CFR 1910.137 the OSHA rule that incorporates ASTM D120 and F696 for electrical gloves. The questions “are nitrile gloves EN 374” and “what does EN 407 mean on gloves” are answered by reading which standard the manufacturer printed and what that standard tests; the list below does that one standard at a time, and the live guide on each standard goes deeper.

Bayshore Safety. Industrial safety and PPE supplier since 2017. · Current as of November 2026 · the Standards, EN 388, EN 374, ANSI/ISEA 105 and 138 lines on the PIP, MCR Safety, Portwest and Radians glove pages on this site (fetched Nov 5–9 2026), with each standard named as the manufacturer prints it; 29 CFR 1910.137(a) and (c) (electrical protective equipment: ASTM D120 and F696 as incorporated), 1910.138, 1910.1030 (current e-CFR); 21 CFR 800.20, 880.6250, 177.2600; FDA Food Code 3-304.15; OSHA Publication 3151; the explanations in the live guides on this site for each standard
MCR Safety CutPro 92724 Cut Resistant Gloves, ANSI A4, Polyurethane CoatedMCR Safety CutPro 92724 Cut Resistant Gloves, ANSI A4, Polyurethane CoatedMCR Safety prints the ANSI/ISEA 105 cut level on this glove; the standards list below reads every such mark (MCR Safety data)

Why there are so many, and why none of them is “the glove standard.” A glove protects against one hazard at a time, and each hazard has its own test. The American system splits them by what is measured: ANSI/ISEA 105 collects the mechanical, thermal and chemical tests for work gloves into one document with a level for each, ANSI/ISEA 138 adds impact, and the ASTM specifications set what a particular product (an examination glove, a surgical glove, an insulating glove) must be. The European system does the same with separate EN standards for mechanical, heat, cold, chemical and biological risks, all built on EN 420 (now EN ISO 21420), the general requirements and sizing standard. Both systems are voluntary consensus standards; what makes some of them binding is adoption by a rule. OSHA’s hand protection standard, 1910.138, names no glove standard at all and leaves selection to the employer on performance characteristics; OSHA’s electrical protective equipment standard, 1910.137, incorporates ASTM D120 (rubber insulating gloves) and F696 (leather protectors) by reference, with its own tables of test voltages and inspection intervals; FDA’s medical-device rules make a patient examination glove a device and set the leak-test AQL in 21 CFR 800.20, with the ASTM D6319, D3578 and D5250 specifications recognized for the material; the Food Code requires single-use gloves without naming a standard, and the food-contact listing in 21 CFR Part 177 is a material rule rather than a glove test. So “what are the safety standards for gloves” is really three questions: which consensus standards the manufacturer tested to (printed on the page), which of them a rule makes mandatory for the job (electrical and medical, mainly), and what the number or letter on the label measures. The manufacturers on this site print the standards they tested to in a Standards line and, for ANSI/ISEA 105 and 138 and EN 388, as separate fields; the list below follows that order.

The standards, one by one: what each tests and what the mark looks like

Grouped by family. The live guide for each standard is linked at the end of the page.

ANSI/ISEA 105 (American work gloves)Cut A1 to A9 (grams of load on a straight blade, ASTM F2992 TDM-100); abrasion 0 to 6 (Taber cycles); puncture 0 to 5 (newtons on a stylus) and needle-stick puncture 0 to 5 (a hypodermic needle); contact heat 1 to 5 (176, 284, 392, 500, 608 °F for 15 seconds, by ASTM F1060); flame, conductive heat and vibration levels. Printed as separate levels on the PIP, MCR Safety, Portwest and Radians pages. The 2024 edition is current.
ANSI/ISEA 138 (impact)Back-of-hand and finger impact in three levels by the force transmitted through the padding: level 1 9 kN or less, 2 6.5 kN or less, 3 4 kN or less. Printed on padded mechanics, oil and gas and impact knit gloves.
EN 388 (European mechanical)Four digits and up to two letters: abrasion 1–4, blade cut 1–5 (coup test), tear 1–4, puncture 1–4, ISO 13997 cut A–F, impact P. An X means not tested. Printed beside the ANSI levels on most knit and leather gloves here; the EN 388 guide reads the code.
EN 407 (heat and flame), EN 511 (cold), EN 16350 (electrostatic)EN 407: six digits for flame, contact heat, convective heat, radiant heat, small and large molten metal splash, each 1–4 or X. EN 511: three digits, convective cold 0–4, contact cold 0–4, water penetration 0 or 1. EN 16350: the glove’s vertical resistance is under 10⁸ ohms, for electrostatic-sensitive or explosive atmospheres. Printed as codes in the Standards line.
EN ISO 374-1 and EN 374-5 (chemical and micro-organisms)374-1: Type A (six test chemicals held 30 minutes or more), Type B (three), Type C (one, 10 minutes), with the letters A to T for the chemicals passed; the performance level 1–6 is the breakthrough time. 374-5: bacteria and fungi, plus “virus” where the glove passed the viral penetration test. Printed on the chemical and the better disposable gloves; the chemical resistance chart guide reads them.
ASTM D6319, D3578, D5250, D3577 (medical glove specifications)Material and product specifications for nitrile, latex and vinyl examination gloves and rubber surgical gloves: dimensions, tensile and elongation, and the freedom-from-holes test the AQL in 21 CFR 800.20 applies. Printed on examination-grade gloves (Radians RWG94: ASTM D6319). ASTM D6978 is the chemotherapy permeation practice printed on chemotherapy-tested gloves.
ASTM D120 and F696 (electrical)D120: rubber insulating gloves in classes 00, 0, 1, 2, 3 and 4 by maximum use voltage (500 V AC for class 00 up to 36,000 V for class 4), with proof-test voltages; F696: the leather protectors worn over them. 29 CFR 1910.137 incorporates both and sets the in-service testing intervals. The NOVAX insulating gloves and PIP 148-series protectors on this site print them; the electrical glove guides explain the classes.
ASTM F1060, F739, F1790 and F2992 (the test methods behind the levels)F1060: conductive and contact heat, the test ANSI/ISEA 105’s heat level reports (PIP prints “ASTM F1060” and the °F figure on its hot mill gloves). F739: chemical permeation (breakthrough time). F1790 and F2992: the cut tests; ANSI/ISEA 105 moved to the F2992 TDM-100 method in 2016. These appear on pages as the source of a figure rather than as a glove rating.
21 CFR Part 177, 21 CFR 800.20, NFPA 1999, CFIA21 CFR 177: FDA food-contact material listing (177.2600 for rubber), printed on food-service gloves. 21 CFR 800.20: the FDA leak-test sampling plan and AQL for medical gloves, the regulatory meaning of medical grade. NFPA 1999: protective clothing and ensembles for emergency medical operations, printed on MCR Safety’s Med Tech 5049. CFIA: the Canadian food inspection listing beside 21 CFR on PIP’s vinyl gloves.

Answers to the standards questions the bank asks

The questions in the bank, answered from the list.

  • What are the ASTM standards for gloves? D6319 (nitrile exam), D3578 (latex exam), D5250 (vinyl exam), D3577 (rubber surgical), D6978 (chemotherapy permeation), D120 (rubber insulating), F696 (leather protectors), F1060 (contact heat), F739 (permeation), F1790 and F2992 (cut), F2878 (hypodermic needle puncture).
  • What are the safety standards for gloves? In the United States, ANSI/ISEA 105 and 138 for work gloves and the ASTM specifications above; in Europe, EN 388, 407, 511, 16350 and EN ISO 374 on the EN 420 / EN ISO 21420 base. The rules that make any of them mandatory are 1910.137 (electrical), the FDA device rules (medical) and the employer’s own selection under 1910.138.
  • Are nitrile gloves EN 374? Only the ones tested and marked: EN ISO 374-1 with a type and letters on chemical nitrile gloves (MCR Safety Nitri-Chem 5350, Portwest A810, PIP Assurance), and EN 374-5 on the disposable nitrile gloves PIP tested for micro-organisms (Ambi-dex Chem, Grippaz). A nitrile glove with no EN 374 mark was not tested to it.
  • What does EN 407 mean on gloves? Heat and flame performance in six digits, each 1 to 4 or X: flammability, contact heat, convective heat, radiant heat, small splashes of molten metal, large quantities of molten metal. PIP prints it on its cold-weather and hot mill gloves where tested (“EN 407 X2XXXX” means contact heat level 2 and nothing else tested).
  • What is MCR protection? The ratings MCR Safety prints on its gloves: ANSI/ISEA 105 cut, abrasion and puncture, ANSI/ISEA 138 impact, EN 388 and EN ISO 374-1, plus its own series names (Cut Pro, Ninja, Predator). The MCR Safety series guide explains the names; the ratings are the standards above.
  • What is MIL-PRF-32432? A United States military performance specification for ballistic eyewear, not a glove standard; the question lands here because the number looks like a glove mark. No glove on this site carries it.
  • What does CE mean on a glove? Conformity with the European PPE Regulation 2016/425, in category I, II or III by risk; the PPE categories guide explains them. It is a European market mark, not a US rating.
The Standards lines on the product pages on this site; 29 CFR 1910.137 and 1910.138; 21 CFR 800.20 and Part 177; the live guides on each standard.
Every standard on the glove pages, what it tests, and the live guide that explains it
StandardTests or specifiesHow it is printedMandatory byGuide
ANSI/ISEA 105Cut A1–A9, abrasion 0–6, puncture 0–5, needle-stick, contact heat 1–5, flame, vibrationSeparate levels on the pageEmployer selection, 1910.138ANSI cut levels; puncture; heat levels
ANSI/ISEA 138Back-of-hand impact 1–3Impact levelEmployer selectionImpact-rated gloves
EN 388Abrasion, cut, tear, puncture, ISO cut, impact4 digits + letters, e.g. 4X42DPCE marking in EuropeEN 388 explained
EN 407Flame, contact, convective, radiant heat, molten metal6 digits, e.g. X2XXXXCE markingHeat-resistant gloves
EN 511Convective cold, contact cold, water3 digits, e.g. 221CE markingCold-weather gloves EN 511
EN ISO 374-1 / EN 374-5Chemical permeation type and letters / micro-organismsType A/B/C + letters; “virus”CE markingChemical resistance chart; solvent by solvent
EN 16350Electrostatic dissipation (<10⁸ Ω)Standards lineCE marking (ATEX areas)—
ASTM D6319 / D3578 / D5250 / D3577Nitrile, latex, vinyl exam gloves; rubber surgical glovesStandards line on exam glovesFDA device rules, 21 CFR 800.20Exam vs surgical gloves
ASTM D6978Chemotherapy drug permeationStandards lineFacility policyExam vs surgical gloves
ASTM D120 / F696Rubber insulating gloves by class; leather protectorsClass and standard on the glove29 CFR 1910.137Electrical insulating gloves
ASTM F1060Contact heat (the ANSI heat level test)°F figure and levelEmployer selectionHeat-resistant gloves
21 CFR Part 177Food-contact material listing“21 CFR” or “FDA food contact”Food Code via state lawAre nitrile gloves food safe
NFPA 1999EMS protective clothing and ensemblesStandards lineFire and EMS department policyGloves for bloodborne pathogens
EN 420 / EN ISO 21420General requirements and sizing (sizes 6–11)Size numberCE markingGlove size numbers vs letters

A glove carries only the standards its manufacturer tested it to; a blank means not tested, not failed.

Source: The Standards lines on the PIP, MCR Safety, Portwest and Radians glove pages on this site; 29 CFR 1910.137, 1910.138; 21 CFR 800.20, 177; the FDA Food Code.

Questions people ask

What are the ASTM standards for gloves?

D6319, D3578 and D5250 for nitrile, latex and vinyl examination gloves, D3577 for rubber surgical gloves, D6978 for chemotherapy permeation, D120 and F696 for rubber insulating gloves and their leather protectors, F1060 for contact heat, F739 for permeation, F1790 and F2992 for cut, F2878 for needle puncture.

What are the safety standards for gloves?

ANSI/ISEA 105 and 138 and the ASTM specifications in the United States; EN 388, 407, 511, 16350 and EN ISO 374 in Europe. OSHA makes ASTM D120 and F696 mandatory for electrical gloves (1910.137) and leaves other selection to the employer (1910.138); FDA regulates medical gloves as devices.

Are nitrile gloves EN 374?

Only when tested and marked: EN ISO 374-1 with a type and letters on chemical nitrile gloves, EN 374-5 on disposable nitrile gloves tested against micro-organisms. No mark means not tested.

What does EN 407 mean on gloves?

Heat and flame performance in six digits (flammability, contact heat, convective heat, radiant heat, small and large molten metal splash), each 1 to 4 or X for not tested.

What does EN 388 mean on gloves?

Mechanical performance: abrasion, blade cut, tear and puncture digits, then the ISO cut letter A to F and P for impact; the EN 388 guide reads a code digit by digit.

What is the difference between ANSI cut levels and EN 388 cut?

ANSI/ISEA 105 reports grams of load on a straight blade in nine levels (A1 to A9); EN 388 reports a coup-test digit 1 to 5 and an ISO 13997 letter A to F from the same kind of straight-blade test. The cut level guide converts between them.

What is MCR protection?

The ratings MCR Safety prints: ANSI/ISEA 105 and 138 levels, EN 388 and EN ISO 374-1 codes, with its series names on top. The standards are the same ones every manufacturer uses.

What is MIL-PRF-32432?

A US military specification for ballistic eyewear, not for gloves; no glove carries it.

Which glove standards does OSHA require?

By name, only ASTM D120 and F696 for rubber insulating gloves and protectors under 1910.137. 1910.138 requires the employer to select hand protection on its performance characteristics, which in practice are the ANSI/ISEA and EN ratings the manufacturer prints.

What standard do exam gloves have to meet?

FDA clears them as medical devices and applies the water-leak sampling plan in 21 CFR 800.20 (2.5 AQL for examination gloves, 1.5 for surgeons’ gloves); ASTM D6319, D3578 and D5250 are the material specifications the manufacturers print.

What does 21 CFR mean on a glove box?

That the glove material is formulated to FDA’s food-contact regulations in 21 CFR Part 177 (177.2600 for rubber articles). It is a material listing, not a glove performance test.

What is EN 420?

The European general requirements standard for gloves (now EN ISO 21420): sizing by hand circumference (size 7 = 178 mm, 8 = 203, 9 = 229, 10 = 254, 11 = 279), pH, chromium VI in leather, marking and information. The number sizes on MCR Safety and Portwest gloves come from it.

The ratings, test results and standards shown here are the manufacturers' published values, reproduced as published. Nothing on this page is a recommendation by Bayshore Safety that any product is suitable for a particular task, hazard or workplace. Selecting safety products and protective equipment is the responsibility of the end user and the employer, based on their own hazard assessment and the regulations that apply to their work. Confirm every value on the manufacturer's own documentation before use.

Need gloves matched to a crew’s work?Call (925) 215-7337 or email us the task, the hazard and the sizes and we will quote by the dozen with the manufacturer’s ratings listed.
Work glove selector

© 2026 Bayshore Safety & Industrial Supplies, Inc. All rights reserved. This guide may not be copied or republished without written permission.

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.