Description
The Draeger 8101801 is the Phosphine 1/a detector tube, measuring range 10 to 100 ppm / 1 to 20 ppm, 2 / 10 pump strokes, measuring time approx. 2 min / approx. 10 min (handbook, p. 250). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Phosphine.
Draeger 8101801 specifications
| Item | Draeger data |
|---|---|
| Part number | 8101801 |
| Gas or substance | Phosphine |
| Tube type | 1/a |
| Measuring range | 10 to 100 ppm / 1 to 20 ppm |
| Number of strokes (n) | 2 / 10 |
| Measuring time | approx. 2 min / approx. 10 min |
| Standard deviation | ± 15 to 20 % |
| Color change | yellow → dark brown |
| Temperature | 5 to 40 °C |
| Humidity | max. 30 mg H2O/L |
| Reaction principle | PH3 + Au3+ → Au (colloidal) |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 250, Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook, p. 250): Arsine and stibine are also indicated, but with lower sensitivities. Hydrogen sulfide, mercaptans, ammonia, and hydrochloric acid are retained in the pre-layer.
Phosphine exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | TWA 0.3 ppm (0.4 mg/m³) |
| NIOSH REL | TWA 0.3 ppm (0.4 mg/m³) ST 1 ppm (1 mg/m³) |
| NIOSH IDLH | 50 ppm |
| CAS number | 7803-51-2 |
| Formula | PH₃ |
| Conversion | 1 ppm = 1.39 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Phosphine (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Phosphine
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| 8101611 | Draeger Phosphine 0.01/a Detector Tubes, Box of 10 | 0.1 to 1.0 ppm / 0.01 to 0.3 ppm | Box of 10 |
| 8103341 | Draeger Phosphine 0.1/b in Acetylene Detector Tubes, Box of 10 | 0.1 to 1 ppm / 1 to 15 ppm | Box of 10 |
| 8103711 | Draeger Phosphine 0.1/c Detector Tubes, Box of 10 | 0.5 to 3 ppm / 0.1 to 1.0 ppm | Box of 10 |
| 8101621 | Draeger Phosphine 25/a Detector Tubes, Box of 10 | 200 to 10000 ppm / 25 to 900 ppm | Box of 10 |
| CH21201 | Draeger Phosphine 50/a Detector Tubes, Box of 10 | 50 to 1000 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Phosphine detector tubes.
Draeger 8101801 questions
What does the Draeger 8101801 measure? Phosphine in air, measuring range 10 to 100 ppm / 1 to 20 ppm.
How many pump strokes does the 8101801 take? 2 / 10 strokes (n) per the handbook, p. 250. Measuring time approx. 2 min / approx. 10 min.
Which pump does the 8101801 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
What is the color change on the 8101801? yellow → dark brown, read against the scale printed on the tube.
Do Draeger 8101801 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of 8101801? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.