Description
The Draeger CH27601 is the Styrene 50/a detector tube, measuring range 50-400 ppm. Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Styrene.
Draeger CH27601 specifications
| Item | Draeger data |
|---|---|
| Part number | CH27601 |
| Gas or substance | Styrene |
| Tube type | 50/a |
| Measuring range | 50-400 ppm |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Draeger published product data.
Styrene exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | TWA 100 ppm C 200 ppm 600 ppm (5-minute maximum peak in any 3 hours) |
| NIOSH REL | TWA 50 ppm (215 mg/m³) ST 100 ppm (425 mg/m³) |
| NIOSH IDLH | 700 ppm |
| CAS number | 100-42-5 |
| Formula | C₆H₅CH=CH₂ |
| Conversion | 1 ppm = 4.26 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Styrene (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Styrene
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| 6723301 | Draeger Styrene 10/a Detector Tubes, Box of 10 | 10 to 200 ppm | Box of 10 |
| 6733141 | Draeger Styrene 10/b Detector Tubes, Box of 10 | 10 to 250 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Styrene detector tubes.
Draeger CH27601 questions
What does the Draeger CH27601 measure? Styrene in air, measuring range 50-400 ppm.
Which pump does the CH27601 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
Do Draeger CH27601 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of CH27601? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.