Description
The Draeger 6733141 is the Styrene 10/b detector tube, measuring range 10 to 250 ppm, 20 pump strokes, measuring time approx. 3 min (handbook, p. 256). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Styrene.
Draeger 6733141 specifications
| Item | Draeger data |
|---|---|
| Part number | 6733141 |
| Gas or substance | Styrene |
| Tube type | 10/b |
| Measuring range | 10 to 250 ppm |
| Number of strokes (n) | 20 |
| Measuring time | approx. 3 min |
| Standard deviation | ± 15 to 20 % |
| Color change | white → reddish brown |
| Temperature | 0 to 40 °C |
| Humidity | 3 to 15 mg H2O/L |
| Reaction principle | Styrene + HCHO → reddish brown reaction product |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 256, Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook, p. 256): Other organic compounds that also react with the formaldehyde-sul- furic acid system affect the reading. A styrene measurement is not possible in these cases. Interfering compounds include, for example, xylene(s), toluene, butadiene, ethylbenzene. The indication is not affected by: 200 ppm methanol 500 ppm octane 400 ppm ethyl acetate
Styrene exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | TWA 100 ppm C 200 ppm 600 ppm (5-minute maximum peak in any 3 hours) |
| NIOSH REL | TWA 50 ppm (215 mg/m³) ST 100 ppm (425 mg/m³) |
| NIOSH IDLH | 700 ppm |
| CAS number | 100-42-5 |
| Formula | C₆H₅CH=CH₂ |
| Conversion | 1 ppm = 4.26 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Styrene (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Styrene
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| 6723301 | Draeger Styrene 10/a Detector Tubes, Box of 10 | 10 to 200 ppm | Box of 10 |
| CH27601 | Draeger Styrene 50/a Detector Tubes, Box of 10 | 50-400 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Styrene detector tubes.
Draeger 6733141 questions
What does the Draeger 6733141 measure? Styrene in air, measuring range 10 to 250 ppm.
How many pump strokes does the 6733141 take? 20 strokes (n) per the handbook, p. 256. Measuring time approx. 3 min.
Which pump does the 6733141 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
What is the color change on the 6733141? white → reddish brown, read against the scale printed on the tube.
Do Draeger 6733141 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of 6733141? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.