Description
The Dräger R59860 is the X-plore 8000 PAPR hoods for the X-plore 8000 powered air-purifying respirator. Ships in 1–2 business days; most orders arrive in 3–7 business days. X-plore 8000 PAPR: every filter, headpiece, part and NIOSH approval on one page.
Dräger R59860 specifications
| Item | Manufacturer data |
|---|---|
| Part numbers | R59860, R59870, R59840, R59850, R59820, R59830, R59800, R59810 |
| System | Dräger X-plore 8000 PAPR |
| R59860 | X-plore 8000 Premium hood, long (S/M) (4 / box) |
| R59870 | X-plore 8000 Premium hood, long (L/XL) (4 / box) |
| R59840 | X-plore 8000 Premium hood, short (S/M) (4 / box) |
| R59850 | X-plore 8000 Premium hood, short (L/XL) (4 / box) |
| R59820 | X-plore 8000 Standard hood, long (S/M) (4 / box) |
| R59830 | X-plore 8000 Standard hood, long (L/XL) (4 / box) |
| R59800 | X-plore 8000 Standard hood, short (S/M) (4 / box) |
| R59810 | X-plore 8000 Standard hood, short (L/XL) (4 / box) |
Source: Dräger Product Catalog, Industrial Applications (DMC-107423); Dräger X-plore 8000 product information (DMC-102510).
X-plore 8000 system data
| Item | Manufacturer data |
|---|---|
| Blower units | R59500 X-plore 8500 (IP) blower unit, IP65, R59550 X-plore 8700 (EX) blower unit, intrinsically safe (Class I, Zone 1, AEx ib IIB T4 Gb) |
| Airflow | Automatic setting by headpiece type; adjustable in three levels: full-face mask 115, 130 or 145 l/min; hoods and helmets 170, 190 or 210 l/min |
| Battery | Lithium-ion 10.8 V / 6.8 Ah (high-capacity battery); operating time 8 to 20 hours depending on flow and contaminant load; charging 4 hours (80% in 2 hours) |
| Weight | X-plore 8500 with standard battery and splash guard lid approx. 3 lbs; X-plore 8700 approx. 3.3 lbs |
| Alarms | Optical, acoustical (at least 80 dB(A) at 3.3 ft) and vibration alarm |
| Belt | Adjustable 27.5 in. to 55 in. (standard and decontamination belts); belt extension 13.8 in. |
| Approval | NIOSH 42 CFR 84 with X-plore 8000 hoods, helmets, X-plore 6000 and FPS 7000 full-face masks |
| Note | Standard long hoods, the disposable hose cover and the welding visor must not be used in potentially explosive atmospheres (pi8000). |
Source: Dräger X-plore 8000 product information (DMC-102510).
NIOSH approvals naming this part
The NIOSH Certified Equipment List carries 5 current Dräger approvals naming it: 1 powered air-purifying (TC-21C), 4 chemical cartridge (TC-23C).
| Approval | Product line | For protection against | Facepiece |
|---|---|---|---|
| TC-21C-1291 | X-plore 8000 PAPR system, R59550 intrinsic safe blower (X-plore 8700), w/premium long hood R59860 (S/M), R59870 (L/XL) a | High-Efficiency | Hood |
| TC-23C-3835 | X-plore 8000 PAPR, R59550 intrinsic safe blower(X-plore 8700), w/premium long hood R59860(S/M), R59870(L/XL) and 6739565 | Chlorine, HEPA (PAPR only), Hydrogen Chloride, Organic Vapor, Sulfur Dioxide | Full Facepiece |
| TC-23C-3839 | X-plore 8000 PAPR system, R59550 intrinsic safe blower(X-plore 8700), w/premium long hood R59860(S/M), R59870(L/XL) and | Ammonia, Chlorine, Formaldehyde, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, M | Full Facepiece |
| TC-23C-3841 | X-plore 8000 PAPR system, R59550 intrinsic safe blower(X-plore 8700), w/premium long hood R59860(S/M), R59870(L/XL) and | Organic Vapor | Full Facepiece |
| TC-23C-3843 | X-plore 8000 PAPR, R59550 intrinsic safe blower(X-plore 8700), w/premium long hood R59860(S/M), R59870 L/XL) and 6739570 | Ammonia, Chlorine, Formaldehyde, HEPA (PAPR only), Hydrogen Chloride, Hydrogen Fluoride, H | Full Facepiece |
Source: NIOSH Certified Equipment List (October 2026), manufacturer Dräger Safety AG & Co. KGaA.
Assigned protection factor
| Respirator type (OSHA Table 1) | APF |
|---|---|
| Powered air-purifying helmet/hood (manufacturer-tested to APF 1,000) | 1000 |
| Powered air-purifying loose-fitting facepiece | 25 |
| Powered air-purifying full facepiece | 1000 |
Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).
Catalog data
| Item | Manufacturer data |
|---|---|
| Style | Short hood; Long hood |
| Size | S/M; L/XL |
| Standards | EN 166; EN 12941 TH3; EN 14594 |
Source: Manufacturer published product data as carried in our catalog.
Lightweight, low-noise hoods for the Draeger X-plore 8000 PAPR and the X-plore 9300 airline system. Short hoods cover head and face with an ear-free design; long hoods add a double layer bib for head, face and neck protection.
- Protection level TH3 with X-plore 8000 (EN 12941)
- Approved to EN 14594 with X-plore 9300 airline
- Premium hoods: oil and water repellent, can be cleaned and disinfected
- Long hoods have a double layer bib that tucks into protective clothing
- Suitable for wearers with glasses and beards
Draeger part number: select an option to see the exact part number.
Available in 8 versions:
- Premium, long (pack of 4) / S/M – R59860
- Premium, short / S/M – R59840
- Standard, long (pack of 4) / S/M – R59820
- Standard, short (pack of 4) / S/M – R59800
- Premium, long (pack of 4) / L/XL – R59870
- Premium, short / L/XL – R59850
- Standard, long (pack of 4) / L/XL – R59830
- Standard, short (pack of 4) / L/XL – R59810
Dräger R59860 questions
What PAPR does the R59860 fit? The Dräger X-plore 8000 system (X-plore 8500 and 8700 blowers).
How long does the X-plore 8000 run on a charge? Lithium-ion 10.8 V / 6.8 Ah (high-capacity battery); operating time 8 to 20 hours depending on flow and contaminant load; charging 4 hours (80% in 2 hours).
Guides: Draeger X-plore filter codes · X-plore 3300 vs 3500 vs 5500 · PAPR vs air-purifying respirators · half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · all North and Draeger respirators by model and hazard.