Description
The MSA 10059903 is the Phosphine/ammonia/chlorine/P100 canister. Ammonia, chlorine and phosphine; Its P100 Particulate Filter (99.97% filter efficiency level) is effective against all particulate aerosols. NIOSH approval TC-14G-0274. Ships in 1–2 business days; most orders arrive in 3–7 business days.
MSA 10059903 specifications
| Item | Manufacturer data |
|---|---|
| MSA part number | 10059903 |
| Canister | Phosphine/ammonia/chlorine/P100 canister |
| NIOSH classes | Phosphine, Ammonia, Chlorine, P100 |
| MSA identification | PH/AM/CL |
| NIOSH approval | TC-14G-0274 |
| Maximum use (MSA) | Maximum Use Conditions: Routine Use: 50 times the Permissible Exposure Level - Do Not Exceed the IDLH concentration. Escape: Contaminant concentrations up to 1500 parts per million (ppm) phosphine, 5000 ppm ammonia, or 5000 ppm chlorine, providing there is sufficient oxygen (19.5 percent by volume) to support life. (MSA Chin-Type Gas Mask for Phosphine/Ammonia/Chlorine data sheet 0515-02-MC); MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025) table: 0.50% / 5000 ppm and 0.15% / 1500 ppm |
| Facepieces MSA names | Chin-type gas mask: G1 (single port APR adapter 10144231-SP required), Advantage 4100 (RD40 adapter 10065330 required), Advantage 3100, Ultravue, Ultra Elite, Millennium facepieces (MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025); CEL 14G-0274 product line) |
| Belt-mounted version | Belt-Mounted Version additional parts: Belt Clip 10068195; Breathing Tube 10068129; PVC Belt 473902; Web Support Belt, uncoated 9961; Polyurethane-coated Nylon Support Belt 492827 (MSA Chin-Type Gas Mask for Phosphine/Ammonia/Chlorine data sheet 0515-02-MC) |
| Color | not stated on the fetched sheets |
Source: MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025); MSA Chin-Type Gas Mask for Phosphine/Ammonia/Chlorine data sheet 0515-02-MC; NIOSH Certified Equipment List (November 2026).
Chin-Type Gas Mask canisters
| MSA Canister | Identification | Protection Code | Color Coding | Approval | Maximum Use % Volume | Maximum Use PPM | Escape Conditions Gas/Vapor | Single Canister |
|---|---|---|---|---|---|---|---|---|
| Phosphine/ammonia/chlorine/P100 canister | PH/AM/CL | (not printed in text) | TC-14G-0274 | 0.50% / 0.15% | 5000 / 1500 | Ammonia, chlorine and phosphine | 10059903* | |
| Organic vapor/P100 canister also effective against organic iodides and iodide vapors | OV | TC-14G-0279 | 0.50% | 5000 | Organic vapors, also effective against organic iodides and iodide vapors | 10067469* | ||
| Hydrogen fluoride/chlorine/P100 canister | HF/CL | TC-14G-0280 | 0.10% | 1000 / 5000 | Hydrogen fluoride and chlorine | 10067491* | ||
| Formaldehyde/acid gas/chlorine dioxide/hydrogen sulfide/P100 canister | FM/AG/CD/HS | TC-14G-0282 | 0.05% / 0.50% / 0.10% | 500 / 5000 / 1000 | Formaldehyde, acid gas, chlorine dioxide and hydrogen sulfide | 10067470* |
*Canister contains a P100 particulate filter (99.97% filter efficiency level) against all particulate amounts.
Source: MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025).
NIOSH approval configurations naming the 10059903
The MSA NIOSH approval inserts list 2 approval configurations naming this part:
| Approval | Protection (insert) | Approval insert | Other cartridges/filters in the row |
|---|---|---|---|
| TC-14G-0274 | P100/PH/AM/CL | Gas Mask Respirator Family | 10051287 |
| TC-14G-0354 | P100/PH/AM/CL | G1 APR | — |
Source: MSA NIOSH approval inserts G1-APR, Gas-Mask-Respirator-Family (material numbers 10160485). Each insert states the respirator is approved only in the listed configurations; the cautions and limitations letters are printed on the insert.
NIOSH approvals naming the 10059903
The NIOSH Certified Equipment List carries 1 current MSA (Mine Safety Appliances Company / MSA Innovation, LLC) approvals whose product line names it: 1 gas mask / CBRN (TC-14G).
| Approval | Product line | For protection against | Facepiece |
|---|---|---|---|
| TC-14G-0274 | Advantage 3100 & 4100 / UltraVue / UltraElite /Millennium facepieces, canister p/n 10059903, and accessories | Ammonia, Chlorine, P100, Phosphine | Full Facepiece |
Source: NIOSH Certified Equipment List (November 2026), manufacturer MSA (Mine Safety Appliances Company / MSA Innovation, LLC).
MSA gas mask use statements
Gas mask use is restricted to entry into, or work within, atmospheres that are within canister limitations. They are not intended for oxygen-deficient atmospheres (less than 19.5% O2). Gas masks may be used for escape only from atmospheres in which the contaminant concentration does not exceed the gas mask maximum use concentration. Chin-Type Gas Masks have the following maximum use limitations: Routine use: 50 times the Permissible Exposure Level (PEL) - Do not exceed the Immediately Dangerous to Life or Health (IDLH) concentration. Escape use: contaminant concentrations up to gas mask maximum use concentrations, providing there is sufficient oxygen to support life. Gas masks are generally suitable for ventilated areas with relatively stable concentration levels. They should never be used within confined spaces, or where oxygen deficiency and/or high gas concentrations may exist.
Never use a gas mask without carefully assessing exposure conditions. Use suitable instruments to determine concentration of oxygen and air contaminants. If exposure concentrations are expected to exceed the specific canister limitations, or are unknown, only a self-contained breathing apparatus or a combination Type C supplied air respirator with auxiliary self-contained air-supply should be used. Always use strictly in accordance with canister labels, gas mask instructions and limitations. DO NOT USE FOR FIREFIGHTING.
Source: MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025); MSA Chin-Type Gas Mask for Phosphine/Ammonia/Chlorine data sheet 0515-02-MC.
Assigned protection factor
| Respirator type (OSHA Table 1) | APF |
|---|---|
| Air-purifying full facepiece | 50 |
Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).
Catalog data
| Item | Manufacturer data |
|---|---|
| Filter Rating | P100 |
| Color | Olive/Magenta |
| Type | Cartridge/Filter |
| Resistance | Ammonia; Chlorine; Phosphine |
| Filtration Grade | P100 |
Source: Manufacturer published product data as carried in our catalog.
MSA chin-style gas mask canister with a P100 filter for the Advantage 3100 facepiece, rated for phosphine, ammonia, methylamine and chlorine. A single threaded canister for chemical plant and pipeline crews who need a P100 gas mask canister rather than twin cartridges.
- Protection: phosphine, ammonia/methylamine, chlorine and P100 particulates
- Threaded chin-style canister connection, single port
- Compatible with MSA Advantage 3100, 4000 and 4100, plus Ultravue and Ultra Elite facepieces
- Olive and magenta color coding identifies the gas and particulate approvals
- NIOSH approved
Environmental and industrial maintenance contractors use this canister on chin-style gas masks during ammonia or chlorine handling where a particulate filter is also required. Manufacturer item number: 10059903. Sold individually.
MSA 10059903 questions
What does the MSA 10059903 protect against? Phosphine, Ammonia, Chlorine, P100 (MSA).
Which facepieces take the 10059903? Chin-type gas mask: G1 (single port APR adapter 10144231-SP required), Advantage 4100 (RD40 adapter 10065330 required), Advantage 3100, Ultravue, Ultra Elite, Millennium facepieces (MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025); CEL 14G-0274 product line).
What are the maximum use conditions for the 10059903? Maximum Use Conditions: Routine Use: 50 times the Permissible Exposure Level - Do Not Exceed the IDLH concentration. Escape: Contaminant concentrations up to 1500 parts per million (ppm) phosphine, 5000 ppm ammonia, or 5000 ppm chlorine, providing there is sufficient oxygen (19.5 percent by volume) to support life. (MSA Chin-Type Gas Mask for Phosphine/Ammonia/Chlorine data sheet 0515-02-MC); MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025) table: 0.50% / 5000 ppm and 0.15% / 1500 ppm.
Guides: cartridge change schedules · P100 vs N95 vs R95 · half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · all respirators by model and hazard.