Description
The MSA Millennium CBRN / Riot Control Gas Mask is a full facepiece gas mask with threaded single canister (riot control, CBRN, P100). Our part numbers: 10051287 (Medium). Super-soft black Hycar rubber exceeds CBRN permeation requirements. The material is impermeable to chemical agents such as mustard. Sizes Small, Medium, Large. Ships in 1–2 business days; most orders arrive in 3–7 business days. Millennium CBRN / Riot Control Gas Mask: every cartridge, filter, part and NIOSH approval on one page.
MSA Millennium CBRN / Riot Control Gas Mask specifications
| Item | Manufacturer data |
|---|---|
| Facepiece type | Full facepiece gas mask |
| Sizes | Small, Medium, Large |
| Our part numbers | 10051287 (Medium) |
| Other versions MSA lists | 10051286 (Small), 10051288 (Large) |
| MSA note | Millennium Gas Mask, with nosecup, drinking tube, and clear polycarbonate outsert. Order either Riot Control or CBRN canisters separately. (MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021)) |
| Materials | Super-soft black Hycar rubber exceeds CBRN permeation requirements. The material is impermeable to chemical agents such as mustard (HD) (MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021)) |
| Cartridge connection | Canister inlet ports on left or right side enables weapon sighting from either side. (threaded canister: 818263 riot control, 10046570 CBRN, 10152979 G1 riot control per inserts) |
| Head harness | Six-point head harness means easy donning, adjustment and removal with no hair pulling. |
| Lens | Flexible, one-piece polyurethane lens eliminates uncomfortable pressure points. |
| Approvals | TC-14G-0270 CBRN Cap 1 with canister 10046570 (CEL: Millennium and Ultra Elite CBRN APR with 10046570 canister); TC-14G-0254 P100/CN/CS with 818263 or 817589 canister; TC-14G-0334 P100/CN/CS with 10152979; 14G-0287 CBRN PAPR Cap 1 (insert) |
| MSA statement | The MSA Millennium CBRN Gas Mask meets or exceeds all performance requirements of the NIOSH CBRN Standard by effectively removing harmful gases, vapors and particulates so that the user can confidently breathe safely. |
| MSA statement | The Millennium CBRN design is based on a highly successful military gas mask. |
| MSA statement | A nose cup is also incorporated for reduced fogging of the facepiece. |
| MSA statement | Riot Control Canisters are also available which protect against common riot control agents such as CN/CS and OC. The Millennium is also approved with a P100 filter for particulate/aerosol protection. |
| MSA statement | Drinking tube allows wearer to ingest water without removing mask. |
Source: MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021); MSA Riot Control Respiratory Protection for First Responders 1000-102-MC; NIOSH Certified Equipment List (November 2026); inserts 818373; 10001974; 10046570.
MSA canisters we list
| Part number | Canister | Protection | Approval | Facepieces MSA names |
|---|---|---|---|---|
| 10059903 | Phosphine/ammonia/chlorine/P100 canister | Phosphine, Ammonia, Chlorine, P100 | TC-14G-0274 | Chin-type gas mask: G1 (single port APR adapter 10144231-SP required), Advantage 4100 (RD40 adapter 10065330 required), Advantage 3100, Ultravue, Ultra Elite, M |
| 10046570 | CBRN Cap-1 canister, for Millennium, G1 and Ultra Elite Facepieces | CBRN Cap 1 | TC-14G-0270 (Millennium, Ultra Elite demand facepiece); TC-14G-0351 (G1 with single port adapter) (MSA Riot Control Resp | Millennium, Ultra Elite (demand), G1 with single port adapter (MSA Riot Control Respiratory Protection for First Responders 1000-102-MC); "The Advantage 4000 ma |
| 817590 | Advantage 1000 Riot Control Agent Canisters, box of 6 | P100 | TC-14G-0235 (Advantage 1000; MSA Riot Control Respiratory Protection for First Responders 1000-102-MC/MSA Advantage 1000 | Advantage 1000 (bayonet canister 817588); Advantage 3200 per MSA Riot Control Respiratory Protection for First Responders 1000-102-MC table (TC-14G-0235) |
| 818264 | Millennium riot control canisters, box of 6 | P100 | TC-14G-0254 (Millennium w/ 818263 or 817589; CEL) | Millennium Gas Mask (MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021); MSA Riot Control Respiratory Protection for First Responders 1000-102-MC) |
Source: MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025); MSA Riot Control Respiratory Protection for First Responders 1000-102-MC; MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021).
Gas mask use is restricted to entry into, or work within, atmospheres that are within canister limitations. They are not intended for oxygen-deficient atmospheres (less than 19.5% O2). Gas masks may be used for escape only from atmospheres in which the contaminant concentration does not exceed the gas mask maximum use concentration. Chin-Type Gas Masks have the following maximum use limitations: Routine use: 50 times the Permissible Exposure Level (PEL) - Do not exceed the Immediately Dangerous to Life or Health (IDLH) concentration. Escape use: contaminant concentrations up to gas mask maximum use concentrations, providing there is sufficient oxygen to support life. Gas masks are generally suitable for ventilated areas with relatively stable concentration levels. They should never be used within confined spaces, or where oxygen deficiency and/or high gas concentrations may exist.
Source: MSA Chin-Type Gas Masks data sheet 0114-20-MC (06.2025).
NIOSH approval configurations for the Millennium CBRN / Riot Control Gas Mask
The MSA NIOSH approval insert for this family lists 11 approval configurations:
| Approval | Protection | Cartridge, filter or canister in the configuration |
|---|---|---|
| TC-14G-0235 | P100/CN/CS | 818264 |
| TC-14G-0254 | P100/CN/CS | 818264 |
| TC-14G-0270 | CBRN Cap 1 | CANISTER |
| TC-14G-0287 | CBRN PAPR Cap 1 | CANISTER; MOISTURE VAPOR BAG FOR CANISTER |
| TC-14G-0296 | CBRN Cap 1 | CANISTER |
| TC-14G-0298 | CBRN PAPR Cap 1 | CANISTER; MOISTURE VAPOR BAG FOR CANISTER |
| TC-14G-0333 | P100/CN/CS | — |
| TC-14G-0334 | P100/CN/CS | — |
| TC-14G-0335 | P100/CS/CN | — |
| TC-14G-0351 | CBRN Cap 1 | CANISTER |
| TC-14G-0352 | CBRN PAPR Cap 1 | CANISTER; MOISTURE VAPOR BAG FOR CANISTER |
Source: MSA NIOSH approval inserts Millennium-Gas-Mask, Millennium-Canister-818263, CBRN-Cap1-Canister-10046570, RIOT-P100-CN-CS-Canister-10152979. The insert states the respirator is approved only in the listed configurations.
NIOSH approvals naming the Millennium
The NIOSH Certified Equipment List carries 10 current MSA (Mine Safety Appliances Company / MSA Innovation, LLC) approvals whose product line names it: 6 gas mask / CBRN (TC-14G), 1 chemical cartridge (TC-23C), 3 air-purifying particulate (TC-84A).
| Approval | Product line | For protection against | Facepiece |
|---|---|---|---|
| TC-14G-0270 | Millennium and Ultra Elite CBRN APR with 10046570 canister | CBRN Cap 1 | Full Facepiece |
| TC-14G-0274 | Advantage 3100 & 4100 / UltraVue / UltraElite /Millennium facepieces, canister p/n 10059903, and accessories | Ammonia, Chlorine, P100, Phosphine | Full Facepiece |
| TC-14G-0279 | UltraVue / UltraElite / Millennium / Advantage 3100 & 4100 Facepieces with 10067469 canister | Organic Vapor, P100 | Full Facepiece |
| TC-14G-0280 | Ultravue / UltraElite / Clearvue / Advantage 3100 & 4100 / Millennium Facepieces with 10067491 canister | Chlorine, Hydrogen Fluoride, P100 | Full Facepiece |
| TC-14G-0282 | Ultravue, Ultra Elite, Clearvue, Advantage 3100 & 4100, Millennium facepieces with 10067470 canister | Chlorine, Chlorine Dioxide, Formaldehyde, Hydrogen Sulfide, P100, Sulfur Dioxide | Full Facepiece |
| TC-14G-0334 | Model Millennium Full Facepiece with Combination Chemical and Filter Canister, Air Purifying Respirator | Chloroacetophenone (CN), Chlorobenzylidene malononitrile (CS), P100 | Full Facepiece |
| TC-23C-2301 | C420 Tight Fitting PAPR with Millennium and Ultra Elite Facepiece | Ammonia, Chlorine, HEPA (PAPR only) | Full Facepiece |
| TC-84A-4314 | Millennium, Ultra Elite, or Ultra Vue facepiece with p/n 495692 P100 filter | P100 | Full Facepiece |
| TC-84A-6720 | Model Millennium Full Facepiece Belt Mounted Air Purifying Respirator with Filter | P100 | Full Facepiece |
| TC-84A-6721 | Model Millennium Full Facepiece Belt Mounted Air Purifying Respirator with Filter | P100 | Full Facepiece |
Source: NIOSH Certified Equipment List (November 2026), manufacturer MSA (Mine Safety Appliances Company / MSA Innovation, LLC).
Assigned protection factor
| Respirator type (OSHA Table 1) | APF |
|---|---|
| Air-purifying full facepiece | 50 |
Source: OSHA 29 CFR 1910.134 Table 1 (Assigned Protection Factors). The APF applies only when the respirator is used in a program that meets the standard, including fit testing of tight-fitting facepieces (29 CFR 1910.134(f)) and a cartridge change schedule (29 CFR 1910.134(d)(3)(iii)).
Millennium CBRN / Riot Control Gas Mask parts and accessories
| Part number | Part |
|---|---|
| 10008907 | Polycarbonate lens outsert, clear, small |
| 10008906 | Polycarbonate lens outsert, clear, medium/large |
| 10026265 | ESP II Communication System, 1-piece, self-contained, electronic speech projection device less battery |
| 10034184 | Gas Mask Pouch, Military Style |
| 816137 | Millennium Spectacle Kit |
Source: MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021); MSA Riot Control Respiratory Protection for First Responders 1000-102-MC; NIOSH Certified Equipment List (November 2026); inserts 818373; 10001974; 10046570.
Canister Test Challenge and Test Breakthrough Concentrations* (NIOSH) - Table 3 from "Statement of Standard for CBRN Ful
| Agent | Concentration (ppm) | Test Breakthrough |
|---|---|---|
| Ammonia | 2500 | 12.5 ppm |
| Cyanogen chloride | 300 | 2 ppm |
| Cyclohexane | 2600 | 10 ppm |
| Formaldehyde | 500 | 1 ppm |
| Hydrogen Cyanide | 940 | 4.7 ppm (Sum of HCN and C2N2) |
| Hydrogen Sulfide | 1000 | 5 ppm |
| Nitrogen Dioxide | 200 | 1 ppm NO2 or 25 ppm NO2 (Nitrogen Dioxide breakthrough is monitored for both NO2 and NO) |
| Phosgene | 250 | 1.25 ppm |
| Phosphine | 300 | 0.3 ppm |
| Sulfur Dioxide | 1500 | 5 ppm |
Source: MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021), quoting NIOSH Statement of Standard for CBRN Full Facepiece APR, Table 3.
Catalog data
| Item | Manufacturer data |
|---|---|
| Facepiece Material | Hycar rubber |
| Harness | 6-point elastic |
| Color | Black |
| Type | Riot Control Gas Mask |
| Material | Rubber |
| Body Material | Hycar™ Rubber |
| Lens Material | Polyurethane |
| Resistance | Biological Agents; Chemical Warfare Agents |
Source: Manufacturer published product data as carried in our catalog.
MSA Millennium riot control gas mask, size medium, is a NIOSH CBRN approved full facepiece respirator with a Hycar rubber facepiece. Its 40mm thread canister connection takes MSA Millennium CBRN and riot control canisters, and it is intended for law enforcement, government and emergency response use.
- Full facepiece gas mask, size medium, black
- Hycar rubber facepiece
- 6-point elastic head harness
- 40mm thread connection; compatible with MSA Millennium CBRN and riot control canisters
- NIOSH and NIOSH CBRN approved
Environmental response contractors and agencies that maintain a CBRN capability stock the Millennium in medium for the majority of personnel. Manufacturer item number: 10051287. Sold individually.
MSA Millennium questions
What cartridges fit the MSA Millennium? Threaded single canister (riot control, CBRN, P100)
What sizes does the Millennium come in? Small, Medium, Large: 10051287 (Medium).
What is the Millennium made of? Super-soft black Hycar rubber exceeds CBRN permeation requirements. The material is impermeable to chemical agents such as mustard (HD) (MSA Millennium Gas Mask bulletin 1012-60-MC (04.2021)).
What is the assigned protection factor of a full facepiece gas mask? OSHA Table 1 assigns an APF of 50 to an air-purifying full facepiece.
Guides: half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · cartridge change schedules · P100 vs N95 vs R95 · all respirators by model and hazard.