Description
Ansell ActivArmr Bi-Color Electrical Insulating Gloves Class 4 - RIG418YBSC: rubber insulating gloves; natural rubber latex, 18.1 in long, straight cuff with rolled beaded edge. EN 388 X243D, ASTM D120 Class 4 (maximum use voltage 36,000 V AC), as Ansell states. 6 part numbers on this page (RIG418YBSC090, RIG418YBSC095, RIG418YBSC100, RIG418YBSC105, RIG418YBSC110, RIG418YBSC120): pick the size above and the part number changes with it. Sizes 9, 9.5, 10, 10.5, 11 and 12. Sold by the pair · 1 pair. Ships in 1–2 business days; most orders arrive in 3–7 business days.
See every Ansell ActivArmr listing and the Ansell ActivArmr Bi-Color Electrical Insulating Gloves Class 4 - RIG418YBSC page.
Ansell RIG418YBSC specifications
| Item | Ansell data |
|---|---|
| Part numbers | RIG418YBSC090, RIG418YBSC095, RIG418YBSC100, RIG418YBSC105, RIG418YBSC110, RIG418YBSC120 |
| Style | RIG418YBSC |
| Series | ActivArmr |
| As Ansell titles it | ActivArmr Bi-Color Electrical Insulating Gloves Class 4 - RIG418YBSC |
| Type | Rubber Insulating Gloves |
| Shell color | Yellow |
| Palm (coating) color | Black |
| Sizes on this page | 9, 9.5, 10, 10.5, 11, 12 |
| Sizes Ansell lists | 9, 9.5, 10, 10.5, 11, Size 12 (not available in Australia) |
| Coating | Natural Rubber Latex |
| Cuff | Straight Cuff with rolled beaded edge |
| Length | 18.1 in (460 mm) |
| Grip | Smooth Finish |
| CE category | Category III |
| Sold by | Pair |
| Prop 65 warning | Yes |
Source: Ansell product page (ActivArmr Bi-Color Electrical Insulating Gloves Class 4 - RIG418YBSC) and the Ansell technical data sheet. Figures are as the manufacturer publishes them for the style.
Ratings and standards, as Ansell states them
| Standard | Ansell data |
|---|---|
| EN 388 | X243D |
| ASTM D120 class | Class 4, maximum use voltage 36,000 V AC (ASTM D120 Table 1) |
| CE category | Category III |
Source: Ansell product page (ActivArmr Bi-Color Electrical Insulating Gloves Class 4 - RIG418YBSC) and the Ansell technical data sheet. Levels and codes are as published by the manufacturer for this style; they are not a hazard assessment for any site.
Ansell RIG418YBSC, as Ansell describes it
- For hand protection with minimal fatigue
- These insulated rubber gloves' non-splayed fingers and hand-at-rest design minimize hand fatigue
- As electrical PPE, they also comply with relevant CSA, NFPA and OSHA standards
Tasks Ansell lists the style for: Applications with risks that involve heat, cuts and abrasions; Electrical Contractors; Hybrid engine manufacturing and repair; Mass Transit Repair and Maintenance; Power maintenance, repair & transmission; Telecom repair near electrical wires.
Industries Ansell names: Automotive, Construction, Infrastructure Maintenance.
Source: Ansell product page (ActivArmr Bi-Color Electrical Insulating Gloves Class 4 - RIG418YBSC) and the Ansell technical data sheet. Wording is the manufacturer's; lines that make a claim rather than state a fact are left out.
What you get
One pair of the rubber insulating gloves in yellow in the size you pick above. Sold by the pair · 1 pair.
- RIG418YBSC090 (9): $915.00
- RIG418YBSC095 (9.5): $915.00
- RIG418YBSC100 (10): $485.00
- RIG418YBSC105 (10.5): $485.00
- RIG418YBSC110 (11): $485.00
- RIG418YBSC120 (12): $485.00
Related Ansell ActivArmr part numbers
| Style | Type | Ratings | Color | Sold by | Price | Listing |
|---|---|---|---|---|---|---|
| RIG418YBSC | Rubber Insulating Gloves | EN 388 X243D, ASTM D120 Class 4 (maximum use voltage 36,000 V AC) | Yellow | Per Pair | {{price:activarmr-bi-color-electrical-insulating-gloves-class-4-rig418ybsc}} | this page |
| RIG0011B | Rubber Insulating Gloves | EN 388 2111A, ASTM D120 Class 00 (maximum use voltage 500 V AC) | Black | Per Pair | {{price:activarmr-electrical-insulating-gloves-class-00-rig0011b}} | Ansell ActivArmr RIG0011B Rubber Insulating Gloves, ASTM D120 Class 00, Per Pair |
| RIG0011BUL | Rubber Insulating Gloves | EN 388 2010X, ASTM D120 Class 00 (maximum use voltage 500 V AC) | Black | Per Pair | {{price:activarmr-ultra-lightweight-electrical-insulating-gloves-class-00-r0011bul}} | Ansell ActivArmr RIG0011BUL Rubber Insulating Gloves, Black, Per Pair |
| RIG0011R | Rubber Insulating Gloves | EN 388 2111A, ASTM D120 Class 00 (maximum use voltage 500 V AC) | Red | Per Pair | {{price:activarmr-electrical-insulating-gloves-class-00-rig0011r}} | Ansell ActivArmr RIG0011R Rubber Insulating Gloves, ASTM D120 Class 00, Per Pair |
| RIG0011Y | Rubber Insulating Gloves | EN 388 2111A, ASTM D120 Class 00 (maximum use voltage 500 V AC) | Yellow | Per Pair | {{price:activarmr-electrical-protection-class-00-rig0011y}} | Ansell ActivArmr RIG0011Y Rubber Insulating Gloves, ASTM D120 Class 00, Per Pair |
| RIG0014B | Rubber Insulating Gloves | EN 388 2111A, ASTM D120 Class 00 (maximum use voltage 500 V AC) | Black | Per Pair | {{price:activarmr-electrical-insulating-gloves-class-00-rig0014b}} | Ansell ActivArmr RIG0014B Rubber Insulating Gloves, ASTM D120 Class 00, Per Pair |
| RIG011B | Rubber Insulating Gloves | EN 388 3121A, ASTM D120 Class 0 (maximum use voltage 1,000 V AC) | Black | Per Pair | {{price:activarmr-electrical-insulating-gloves-class-0-rig011b}} | Ansell ActivArmr RIG011B Rubber Insulating Gloves, ASTM D120 Class 0, Per Pair |
| RIG011R | Rubber Insulating Gloves | EN 388 3121A, ASTM D120 Class 0 (maximum use voltage 1,000 V AC) | Red | Per Pair | {{price:activarmr-electrical-insulating-gloves-class-0-rig011r}} | Ansell ActivArmr RIG011R Rubber Insulating Gloves, ASTM D120 Class 0, Per Pair |
| RIG011Y | Rubber Insulating Gloves | EN 388 3121A, ASTM D120 Class 0 (maximum use voltage 1,000 V AC) | Yellow | Per Pair | {{price:activarmr-electrical-protection-class-0-rig011y}} | Ansell ActivArmr RIG011Y Rubber Insulating Gloves, ASTM D120 Class 0, Per Pair |
| RIG014B | Rubber Insulating Gloves | ASTM D120 Class 0 (maximum use voltage 1,000 V AC) | Black | Per Pair | {{price:activarmr-electrical-insulating-gloves-class-0-rig014b}} | Ansell ActivArmr RIG014B Rubber Insulating Gloves, ASTM D120 Class 0, Per Pair |
| RIG014Y | Rubber Insulating Gloves | EN 388 3121A, ASTM D120 Class 0 (maximum use voltage 1,000 V AC) | Yellow | Per Pair | {{price:activarmr-electrical-insulating-gloves-class-0-rig014y}} | Ansell ActivArmr RIG014Y Rubber Insulating Gloves, ASTM D120 Class 0, Per Pair |
| RIG014YBSC | Rubber Insulating Gloves | EN 388 3121A, ASTM D120 Class 0 (maximum use voltage 1,000 V AC) | Black | Per Pair | {{price:activarmr-bi-color-electrical-insulating-gloves-class-0-rig014ybsc}} | Ansell ActivArmr RIG014YBSC Rubber Insulating Gloves, Black, Per Pair |
| RIG114B | Rubber Insulating Gloves | EN 388 3122B, ASTM D120 Class 1 (maximum use voltage 7,500 V AC) | Black | Per Pair | {{price:activarmr-electrical-protection-class-1-rig114b}} | Ansell ActivArmr RIG114B Rubber Insulating Gloves, ASTM D120 Class 1, Per Pair |
Every Ansell ActivArmr listing we stock is on the Ansell ActivArmr page (61 listings).
Source: Styles and ratings as Ansell prints them; prices are ours.
Ansell RIG418YBSC sizes and part numbers
| Size | Part number | Pair count | Price |
|---|---|---|---|
| 9 | RIG418YBSC090 | — | $915.00 |
| 9.5 | RIG418YBSC095 | — | $915.00 |
| 10 | RIG418YBSC100 | — | $485.00 |
| 10.5 | RIG418YBSC105 | — | $485.00 |
| 11 | RIG418YBSC110 | — | $485.00 |
| 12 | RIG418YBSC120 | — | $485.00 |
Source: Sizes and part numbers as Ansell prints them; prices are ours. Ansell lists sizes 9, 9.5, 10, 10.5, 11, Size 12 (not available in Australia).
Ansell RIG418YBSC questions
What is the Ansell RIG418YBSC? Ansell titles it "ActivArmr Bi-Color Electrical Insulating Gloves Class 4 - RIG418YBSC": rubber insulating gloves. Ansell states EN 388 X243D and ASTM D120 Class 4 (maximum use voltage 36,000 V AC).
What is the EN 388 standard for gloves? The European glove standard: four numbers for abrasion, blade cut, tear and puncture, then a letter A to F for the ISO 13997 cut test and P where impact was tested. Ansell states EN 388 X243D for the RIG418YBSC.
What does the ASTM D120 class mean? ASTM D120 classes rubber insulating gloves 00, 0, 1, 2, 3 and 4 by proof-test voltage and maximum use voltage; Class 4 is rated for use up to 36,000 V AC. Ansell states Class 4 for the RIG418YBSC.
How often should insulating gloves be tested? OSHA 1910.137(c)(2)(viii) has rubber insulating gloves electrically tested before first issue and every six months after, and at once after any suspected damage; leather protectors are worn over them except in the cases 1910.137(c)(2)(vii) lists.
How can I tell what my glove size is? Measure around the palm at the knuckles, without the thumb: about 7 in is size 7 (S), 8 in size 8 (M), 9 in size 9 (L), 10 in size 10 (XL), 11 in size 11 (2XL). Ansell lists sizes 9, 9.5, 10, 10.5, 11, Size 12 (not available in Australia) for the style; the glove size guide below has the chart.
How is the Ansell RIG418YBSC sold? Sold by the pair · 1 pair. The price on each line of the size table is for that part number.
Guides: Electrical insulating rubber gloves · Rubber insulating gloves and leather protectors · How often do electrical gloves have to be tested · Do electric gloves exist · What PPE should an electrician wear · NFPA 70E PPE categories 1 to 4.
Ansell RIG418YBSC documents
- Ansell technical data sheet (product data sheet)
- Instructions for use
- Ansell ActivArmr Bi-Color Electrical Insulating Gloves Class 4 - RIG418YBSC product page (features, standards, product details, packaging, downloads)
Source: Ansell product page download list; Ansell serves its data sheets from the product page.
Manufacturer item number: RIG418YBSC090, RIG418YBSC095, RIG418YBSC100, RIG418YBSC105, RIG418YBSC110, RIG418YBSC120. Style RIG418YBSC.