6 Draeger short-term detector tubes for Carbon dioxide, measuring ranges from 100 to 3000 ppm up to 5 to 60 Vol%. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 138–142); prices are live. Ships in 1–2 business days.
Every Draeger tube for Carbon dioxide
| Part number | Tube | Measuring range | Strokes (n) | Measuring time | Color change | Pack | Price | |
|---|---|---|---|---|---|---|---|---|
| 8101811 | Draeger Carbon Dioxide 100/a Detector Tubes, Box of 10 | 100 to 3000 ppm | 10 | approx. 4 min | white to light | Box of 10 | $105.81 | |
| CH23501 | Draeger Carbon Dioxide 0.1%/a Detector Tubes, Box of 10 | 0.5 to 6 Vol% / 0.1 to 1.2 Vol% | 1 /5 | approx. 30 s / approx. 2.5 min | white → purple | Box of 10 | $93.31 | |
| CH31401 | Draeger Carbon Dioxide 0.5%/a Detector Tubes, Box of 10 | 0.5 to 10 Vol% | 1 | approx. 30 s | white → purple | Box of 10 | $105.02 | |
| CH25101 | Draeger Carbon Dioxide 1%/a Detector Tubes, Box of 10 | 1 to 20 Vol% | 1 | approx. 30 s | white → purple | Box of 10 | $106.37 | |
| CH20301 | Draeger Carbon Dioxide 5%/a Detector Tubes, Box of 10 | 5 to 60 Vol% | 1 | approx. 2 min | white → purple | Box of 10 | $132.83 | |
| 6728521 | Draeger Carbon Dioxide 100/a-P Tubes for Aerotest, Box of 10 | 100 to 3000 ppm | approx. 5 min | white → purple | Box of 10 | $131.92 |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 138–142, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.
Draeger MicroTubes for Carbon dioxide (X-act 7000)
| MicroTube | Measuring range | Price |
|---|---|---|
| Draeger Carbon Dioxide MicroTube for X-act 7000, 200-50000 ppm | 200-50000 ppm | $117.81 |
MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.
Carbon dioxide exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | TWA 5000 ppm (9000 mg/m³) |
| NIOSH REL | TWA 5000 ppm (9000 mg/m³) ST 30,000 ppm (54,000 mg/m³) |
| NIOSH IDLH | 40,000 ppm |
| CAS number | 124-38-9 |
| Formula | CO₂ |
| Other names | Carbonic acid gas, Dry ice [Note: Normal constituent of air (about 300 ppm)]. |
| Conversion | 1 ppm = 1.80 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Carbon dioxide (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless, odorless gas. [Note: Shipped as a liquefied compressed gas. Solid form is utilized as dry ice.]
Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.
Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.
Draeger Carbon dioxide tube questions
Which Draeger tubes measure Carbon dioxide? 8101811 (100 to 3000 ppm), CH23501 (0.5 to 6 Vol% / 0.1 to 1.2 Vol%), CH31401 (0.5 to 10 Vol%), CH25101 (1 to 20 Vol%), CH20301 (5 to 60 Vol%), 6728521 (100 to 3000 ppm).
What is the lowest range Draeger tube for Carbon dioxide? 8101811, 100 to 3000 ppm, 10 strokes.
What is the OSHA exposure limit for Carbon dioxide? OSHA PEL TWA 5000 ppm (9000 mg/m³); NIOSH REL TWA 5000 ppm (9000 mg/m³) ST 30,000 ppm (54,000 mg/m³); IDLH 40,000 ppm (NIOSH Pocket Guide).
Which pump reads Draeger Carbon dioxide tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.
Do Draeger Carbon dioxide tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).