Draeger Chlorine Detector Tubes
2 Draeger short-term detector tubes for Chlorine, measuring ranges from 0.2 to 3 ppm / 3 to 30 ppm up to 50 to 500 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 153–154); prices are live. Ships in 1–2 business days.
Every Draeger tube for Chlorine
| Part number | Tube | Measuring range | Strokes (n) | Measuring time | Color change | Pack | Price | ||
|---|---|---|---|---|---|---|---|---|---|
![]() | CH24301 | Draeger Chlorine 0.2/a Detector Tubes, Box of 10 | 0.2 to 3 ppm / 3 to 30 ppm | 10 /1 | approx. 180 s / approx. 20 s | white → yellow-orange | Box of 10 | $92.12 | |
![]() | CH20701 | Draeger Chlorine 50/a Detector Tubes, Box of 10 | 50 to 500 ppm | 1 | approx. 20 s | gray-green → orange-brown | Box of 10 | $131.38 |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 153–154, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.
Draeger MicroTubes for Chlorine (X-act 7000)
| MicroTube | Measuring range | Price |
|---|---|---|
| Draeger Chlorine MicroTube for X-act 7000, 50-5000 ppb | 50-5000 ppb | $117.81 |
MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.
Chlorine exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | C 1 ppm (3 mg/m³) |
| NIOSH REL | C 0.5 ppm (1.45 mg/m³) [15-minute] |
| NIOSH IDLH | 10 ppm |
| CAS number | 7782-50-5 |
| Formula | Cl₂ |
| Other names | Molecular chlorine |
| Conversion | 1 ppm = 2.90 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Chlorine (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Greenish-yellow gas with a pungent, irritating odor. [Note: Shipped as a liquefied compressed gas.]
Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.
Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.
Draeger Chlorine tube questions
Which Draeger tubes measure Chlorine? CH24301 (0.2 to 3 ppm / 3 to 30 ppm), CH20701 (50 to 500 ppm).
What is the lowest range Draeger tube for Chlorine? CH24301, 0.2 to 3 ppm / 3 to 30 ppm, 10 /1 strokes.
What is the OSHA exposure limit for Chlorine? OSHA PEL C 1 ppm (3 mg/m³); NIOSH REL C 0.5 ppm (1.45 mg/m³) [15-minute]; IDLH 10 ppm (NIOSH Pocket Guide).
Which pump reads Draeger Chlorine tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.
Do Draeger Chlorine tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).