Draeger Chlorine Detector Tubes

2 Draeger short-term detector tubes for Chlorine, measuring ranges from 0.2 to 3 ppm / 3 to 30 ppm up to 50 to 500 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 153–154); prices are live. Ships in 1–2 business days.

Every Draeger tube for Chlorine

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
CH24301Draeger Chlorine 0.2/a Detector Tubes, Box of 100.2 to 3 ppm / 3 to 30 ppm10 /1approx. 180 s / approx. 20 swhite → yellow-orangeBox of 10$92.12
CH20701Draeger Chlorine 50/a Detector Tubes, Box of 1050 to 500 ppm1approx. 20 sgray-green → orange-brownBox of 10$131.38

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 153–154, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Draeger MicroTubes for Chlorine (X-act 7000)

MicroTubeMeasuring rangePrice
Draeger Chlorine MicroTube for X-act 7000, 50-5000 ppb50-5000 ppb$117.81

MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.

Chlorine exposure limits

LimitValue
OSHA PELC 1 ppm (3 mg/m³)
NIOSH RELC 0.5 ppm (1.45 mg/m³) [15-minute]
NIOSH IDLH10 ppm
CAS number7782-50-5
FormulaCl₂
Other namesMolecular chlorine
Conversion1 ppm = 2.90 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Chlorine (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Greenish-yellow gas with a pungent, irritating odor. [Note: Shipped as a liquefied compressed gas.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Chlorine tube questions

Which Draeger tubes measure Chlorine? CH24301 (0.2 to 3 ppm / 3 to 30 ppm), CH20701 (50 to 500 ppm).

What is the lowest range Draeger tube for Chlorine? CH24301, 0.2 to 3 ppm / 3 to 30 ppm, 10 /1 strokes.

What is the OSHA exposure limit for Chlorine? OSHA PEL C 1 ppm (3 mg/m³); NIOSH REL C 0.5 ppm (1.45 mg/m³) [15-minute]; IDLH 10 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Chlorine tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Chlorine tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.