Skip to main content
Draeger detector tubes · Ethyl acetate

Draeger Ethyl Acetate Detector Tubes

1 Draeger short-term detector tube for Ethyl acetate, measuring range 200 to 3000 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (p. 172); prices are live. Ships in 1–2 business days.

Every Draeger tube for Ethyl acetate

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
CH20201Draeger Ethyl Acetate 200/a Detector Tubes, Box of 10200 to 3000 ppm20approx. 5 minorange → green-brownBox of 10$106.07

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 172, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Ethyl acetate exposure limits

LimitValue
OSHA PELTWA 400 ppm (1400 mg/m³)
NIOSH RELTWA 400 ppm (1400 mg/m³)
NIOSH IDLH2000 ppm [10%LEL]
CAS number141-78-6
FormulaCH₃COOC₂H₅
Other namesAcetic ester, Acetic ether, Ethyl ester of acetic acid, Ethyl ethanoate
Conversion1 ppm = 3.60 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Ethyl acetate (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless liquid with an ether-like, fruity odor.

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Ethyl acetate tube questions

Which Draeger tubes measure Ethyl acetate? CH20201 (200 to 3000 ppm).

What is the lowest range Draeger tube for Ethyl acetate? CH20201, 200 to 3000 ppm, 20 strokes.

What is the OSHA exposure limit for Ethyl acetate? OSHA PEL TWA 400 ppm (1400 mg/m³); NIOSH REL TWA 400 ppm (1400 mg/m³); IDLH 2000 ppm [10%LEL] (NIOSH Pocket Guide).

Which pump reads Draeger Ethyl acetate tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Ethyl acetate tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.