2 Draeger short-term detector tubes for Hydrogen fluoride, measuring ranges from 0.5 to 15 ppm / 10 to 90 ppm up to 1.5 to 15 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 199–200); prices are live. Ships in 1–2 business days.

Every Draeger tube for Hydrogen fluoride

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8103251Draeger Hydrogen Fluoride 0.5/a Detector Tubes, Box of 100.5 to 15 ppm / 10 to 90 ppm10 /2approx. 2 min / approx. 25 sviolet-blue → yellowBox of 10$142.14
CH30301Draeger Hydrogen Fluoride 1.5/b Detector Tubes, Box of 101.5 to 15 ppm20approx. 2 minlight blue → light pinkBox of 10$141.35

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 199–200, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Hydrogen fluoride exposure limits

LimitValue
OSHA PELTWA 3 ppm
NIOSH RELTWA 3 ppm (2.5 mg/m³) C 6 ppm (5 mg/m³) [15-minute]
NIOSH IDLH30 ppm
CAS number7664-39-3
FormulaHF
Other namesAnhydrous hydrogen fluoride, Aqueous hydrogen fluoride, HF-A, Hydrofluoric acid
Conversion1 ppm = 0.82 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Hydrogen fluoride (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless gas or fuming liquid (below 67°F) with a strong, irritating odor. [Note: Shipped in cylinders.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Hydrogen fluoride tube questions

Which Draeger tubes measure Hydrogen fluoride? 8103251 (0.5 to 15 ppm / 10 to 90 ppm), CH30301 (1.5 to 15 ppm).

What is the lowest range Draeger tube for Hydrogen fluoride? 8103251, 0.5 to 15 ppm / 10 to 90 ppm, 10 /2 strokes.

What is the OSHA exposure limit for Hydrogen fluoride? OSHA PEL TWA 3 ppm; NIOSH REL TWA 3 ppm (2.5 mg/m³) C 6 ppm (5 mg/m³) [15-minute]; IDLH 30 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Hydrogen fluoride tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Hydrogen fluoride tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.