Description
The Draeger CH30301 is the Hydrogen fluoride 1.5/b detector tube, measuring range 1.5 to 15 ppm, 20 pump strokes, measuring time approx. 2 min (handbook, p. 200). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Hydrogen fluoride.
Draeger CH30301 specifications
| Item | Draeger data |
|---|---|
| Part number | CH30301 |
| Gas or substance | Hydrogen fluoride |
| Tube type | 1.5/b |
| Measuring range | 1.5 to 15 ppm |
| Number of strokes (n) | 20 |
| Measuring time | approx. 2 min |
| Standard deviation | ± 15 to 20 % |
| Color change | light blue → light pink |
| Temperature | 15 to 30 °C |
| Humidity | max. 9 mg H2O/L |
| Reaction principle | HF + Zr(OH)4/quinalizarin → [ZrF6]2– + quinalizarin |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 200, Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook, p. 200): Other halogen hydracids do not have any effect within their OEL ranges. In the presence of higher humidity than shown above, hydrogen fluoride mist is generated, which cannot be quantitatively indicated by the tube, i.e., the indication is too low.
Hydrogen fluoride exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | TWA 3 ppm |
| NIOSH REL | TWA 3 ppm (2.5 mg/m³) C 6 ppm (5 mg/m³) [15-minute] |
| NIOSH IDLH | 30 ppm |
| CAS number | 7664-39-3 |
| Formula | HF |
| Conversion | 1 ppm = 0.82 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Hydrogen fluoride (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Hydrogen fluoride
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| 8103251 | Draeger Hydrogen Fluoride 0.5/a Detector Tubes, Box of 10 | 0.5 to 15 ppm / 10 to 90 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Hydrogen fluoride detector tubes.
Draeger CH30301 questions
What does the Draeger CH30301 measure? Hydrogen fluoride in air, measuring range 1.5 to 15 ppm.
How many pump strokes does the CH30301 take? 20 strokes (n) per the handbook, p. 200. Measuring time approx. 2 min.
Which pump does the CH30301 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
What is the color change on the CH30301? light blue → light pink, read against the scale printed on the tube.
Do Draeger CH30301 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of CH30301? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.