Description
The Draeger 8103251 is the Hydrogen fluoride 0.5/a detector tube, measuring range 0.5 to 15 ppm / 10 to 90 ppm, 10 /2 pump strokes, measuring time approx. 2 min / approx. 25 s (handbook, p. 199). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Hydrogen fluoride.
Draeger 8103251 specifications
| Item | Draeger data |
|---|---|
| Part number | 8103251 |
| Gas or substance | Hydrogen fluoride |
| Tube type | 0.5/a |
| Measuring range | 0.5 to 15 ppm / 10 to 90 ppm |
| Number of strokes (n) | 10 /2 |
| Measuring time | approx. 2 min / approx. 25 s |
| Standard deviation | ± 20 to 30 % |
| Color change | violet-blue → yellow |
| Temperature | 10 to 40 °C |
| Humidity | 30 to 80 % |
| Reaction principle | HF + pH indicator → yellow reaction product |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 199, Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook, p. 199): Mineral acids, such as hydrochloric acid or nitric acid, are also indicated. Alkaline gases, such as ammonia, cause minus errors or can prevent an indication entirely.
Hydrogen fluoride exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | TWA 3 ppm |
| NIOSH REL | TWA 3 ppm (2.5 mg/m³) C 6 ppm (5 mg/m³) [15-minute] |
| NIOSH IDLH | 30 ppm |
| CAS number | 7664-39-3 |
| Formula | HF |
| Conversion | 1 ppm = 0.82 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Hydrogen fluoride (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Hydrogen fluoride
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| CH30301 | Draeger Hydrogen Fluoride 1.5/b Detector Tubes, Box of 10 | 1.5 to 15 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Hydrogen fluoride detector tubes.
Draeger 8103251 questions
What does the Draeger 8103251 measure? Hydrogen fluoride in air, measuring range 0.5 to 15 ppm / 10 to 90 ppm.
How many pump strokes does the 8103251 take? 10 /2 strokes (n) per the handbook, p. 199. Measuring time approx. 2 min / approx. 25 s.
Which pump does the 8103251 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
What is the color change on the 8103251? violet-blue → yellow, read against the scale printed on the tube.
Do Draeger 8103251 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of 8103251? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.