Skip to main content
Draeger detector tubes · Hydrogen sulfide

Draeger Hydrogen Sulfide Detector Tubes

11 Draeger short-term detector tubes for Hydrogen sulfide, measuring ranges from 0.2 to 5 ppm up to 2 to 40 Vol%. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 202–212); prices are live. Ships in 1–2 business days.

Every Draeger tube for Hydrogen sulfide

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
8101461Draeger Hydrogen Sulfide 0.2/a Detector Tubes, Box of 100.2 to 5 ppm10approx. 5 minwhite → light brownBox of 10$113.65
8101991Draeger Hydrogen Sulfide 0.2/b Detector Tubes, Box of 100.2 to 6 ppm1approx. 55 syellow → pinkBox of 10$126.19
6728041Draeger Hydrogen Sulfide 0.5/a Detector Tubes, Box of 100.5 to 15 ppm / 5 to 150 ppm10 /1approx. 6 min / approx. 40 swhite → light brownBox of 10$113.21
8101961Draeger Hydrogen Sulfide 2/b Detector Tubes, Box of 102 to 60 ppm1approx. 30 swhite → light brownBox of 10$113.12
CH29801Draeger Hydrogen Sulfide 5/b Detector Tubes, Box of 105 to 60 ppm10approx. 4 minwhite → brownBox of 10$113.50
6719001Draeger Hydrogen Sulfide 1/c Detector Tubes, Box of 1010 to 200 ppm / 1 to 20 ppm1 / 10approx. 20 s / approx. 3 minwhite → light brownBox of 10$112.71
8101831Draeger Hydrogen Sulfide 1/d Detector Tubes, Box of 1010 to 200 ppm / 1 to 20 ppm1 / 10approx. 1 min / approx. 10 minwhite → brownBox of 10$112.30
6728821Draeger Hydrogen Sulfide 2/a Detector Tubes, Box of 1020 to 200 ppm / 2 to 20 ppm1 / 10approx. 20 s / approx. 3.5 minwhite → light brownBox of 10$112.97
CH29101Draeger Hydrogen Sulfide 100/a Detector Tubes, Box of 10100 to 2000 ppm1approx. 30 swhite → brownBox of 10$113.65
CH28101Draeger Hydrogen Sulfide 0.2%/A Detector Tubes, Box of 100.2 to 7 Vol%1 + 2 desorption strokesapprox. 2 minlight blue → blackBox of 10$126.32
8101211Draeger Hydrogen Sulfide 2%/a Detector Tubes, Box of 102 to 40 Vol%1approx. 60 slight blue → blackBox of 10$126.07

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 202–212, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Draeger MicroTubes for Hydrogen sulfide (X-act 7000)

MicroTubeMeasuring rangePrice
Draeger Hydrogen Sulfide MicroTubes for X-act 70000.1-50 ppm; 100-2000 ppm$103.67

MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.

Hydrogen sulfide exposure limits

LimitValue
OSHA PELC 20 ppm 50 ppm [10-minute maximum peak]
NIOSH RELC 10 ppm (15 mg/m³) [10-minute]
NIOSH IDLH100 ppm
CAS number7783-06-4
FormulaH₂S
Other namesHydrosulfuric acid, Sewer gas, Sulfuretted hydrogen
Conversion1 ppm = 1.40 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Hydrogen sulfide (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless gas with a strong odor of rotten eggs. [Note: Sense of smell becomes rapidly fatigued & can NOT be relied upon to warn of the continuous presence of H2S. Shipped as a liquefied compressed gas.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Hydrogen sulfide tube questions

Which Draeger tubes measure Hydrogen sulfide? 8101461 (0.2 to 5 ppm), 8101991 (0.2 to 6 ppm), 6728041 (0.5 to 15 ppm / 5 to 150 ppm), 8101961 (2 to 60 ppm), CH29801 (5 to 60 ppm), 6719001 (10 to 200 ppm / 1 to 20 ppm), 8101831 (10 to 200 ppm / 1 to 20 ppm), 6728821 (20 to 200 ppm / 2 to 20 ppm), CH29101 (100 to 2000 ppm), CH28101 (0.2 to 7 Vol%), 8101211 (2 to 40 Vol%).

What is the lowest range Draeger tube for Hydrogen sulfide? 8101461, 0.2 to 5 ppm, 10 strokes.

What is the OSHA exposure limit for Hydrogen sulfide? OSHA PEL C 20 ppm 50 ppm [10-minute maximum peak]; NIOSH REL C 10 ppm (15 mg/m³) [10-minute]; IDLH 100 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Hydrogen sulfide tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Hydrogen sulfide tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.