Skip to main content
Draeger detector tubes · Sulfur dioxide

Draeger Sulfur Dioxide Detector Tubes

5 Draeger short-term detector tubes for Sulfur dioxide, measuring ranges from 0.1 to 3 ppm up to 50 to 500 ppm. Ranges, pump strokes, measuring times and color changes as published in the Dräger-Tubes & MicroTubes Handbook, 22nd edition (pp. 257–261); prices are live. Ships in 1–2 business days.

Every Draeger tube for Sulfur dioxide

Part numberTubeMeasuring rangeStrokes (n)Measuring timeColor changePackPrice
6727101Draeger Sulfur Dioxide 0.1/a Detector Tubes, Box of 100.1 to 3 ppm100approx. 20 minyellow → orangeBox of 10$137.04
6728491Draeger Sulfur Dioxide 0.5/a Detector Tubes, Box of 101 to 25 ppm / 0.5 to 5 ppm10 / 20approx. 3 min / approx. 6 mingray-blue → whiteBox of 10$116.78
CH31701Draeger Sulfur Dioxide 1/a Detector Tubes, Box of 101 to 25 ppm10approx. 3 mingray-blue → whiteBox of 10$106.17
CH24201Draeger Sulfur Dioxide 20/a Detector Tubes, Box of 1020 to 200 ppm10approx. 3 minbrown-yellow → whiteBox of 10$135.51
8101531Draeger Sulfur Dioxide 50/b Detector Tubes, Box of 10400 to 8000 ppm / 50 to 500 ppm1 / 10approx. 15 s / approx. 3 minblue → yellowBox of 10$136.33

Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), pp. 257–261, Dräger Safety AG & Co. KGaA. Each tube page carries the full handbook entry: standard deviation, temperature and humidity limits, reaction principle and cross-sensitivities.

Draeger MicroTubes for Sulfur dioxide (X-act 7000)

MicroTubeMeasuring rangePrice
Draeger Sulfur Dioxide MicroTube for X-act 7000, 0.05-5 ppm0.05-5 ppm$117.81

MicroTubes are read electronically on the Draeger X-act 7000, not on a hand pump.

Sulfur dioxide exposure limits

LimitValue
OSHA PELTWA 5 ppm (13 mg/m³)
NIOSH RELTWA 2 ppm (5 mg/m³) ST 5 ppm (13 mg/m³)
NIOSH IDLH100 ppm
CAS number7446-09-5
FormulaSO₂
Other namesSulfur oxide, Sulfurous acid anhydride, Sulfurous oxide
Conversion1 ppm = 2.62 mg/m³

Source: NIOSH Pocket Guide to Chemical Hazards, Sulfur dioxide (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen. NIOSH physical description: Colorless gas with a characteristic, irritating, pungent odor. [Note: A liquid below 14°F. Shipped as a liquefied compressed gas.]

Draeger short-term tubes are read on a Draeger accuro or X-act 5000 tube pump. Per the handbook (pp. 28–29), Draeger tubes and Draeger pumps are matched at the factory and form a single unit; other makers' pumps and tubes are not interchangeable with them. All Draeger tubes A–Z.

Guides: Draeger tubes by gas and range · tube ranges and the OSHA and NIOSH limits · what Draeger tubes measure · what the tube names mean · how to read a tube · the accuro pump.

Draeger Sulfur dioxide tube questions

Which Draeger tubes measure Sulfur dioxide? 6727101 (0.1 to 3 ppm), 6728491 (1 to 25 ppm / 0.5 to 5 ppm), CH31701 (1 to 25 ppm), CH24201 (20 to 200 ppm), 8101531 (400 to 8000 ppm / 50 to 500 ppm).

What is the lowest range Draeger tube for Sulfur dioxide? 6727101, 0.1 to 3 ppm, 100 strokes.

What is the OSHA exposure limit for Sulfur dioxide? OSHA PEL TWA 5 ppm (13 mg/m³); NIOSH REL TWA 2 ppm (5 mg/m³) ST 5 ppm (13 mg/m³); IDLH 100 ppm (NIOSH Pocket Guide).

Which pump reads Draeger Sulfur dioxide tubes? The Draeger accuro hand pump or the X-act 5000 pump. MicroTubes, where listed, are read on the X-act 7000.

Do Draeger Sulfur dioxide tubes expire? Yes. The expiration date (month and year) is printed on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).

How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.