Description
DuPont Tychem 10000 TK613T encapsulated suit level a in lime yellow: multi-layer barrier films laminated to both sides of a 4.0 oz/yd2 polyester substrate. DuPont titles it "Encap. Level A, Expanded Back, Rear Entry. Certified to NFPA 1990 (NFPA 1994, Class 2) 2022 edition". DuPont reports at least 30 minutes of barrier protection against 322 challenge chemicals with no observed breakthrough; a puncture- and tear-resistant fabric for the highest level of liquid splash protection in the Tychem line, as DuPont describes the fabric. DuPont states NFPA 1990, NFPA 1994 Class 2 and 16 CFR 1610 Class 1 for this garment. Fabric basis weight 12 oz/yd2 and thickness 28 mils, as DuPont prints it. 3 part numbers on this page (TK613TLYLG000100, TK613TLYXL000100, TK613TLY2X000100): pick the size above and the part number changes with it. Sizes Large, XL and 2XL. Sold by the each · 1 suit. Ships in 1–2 business days; most orders arrive in 3–7 business days.
See every DuPont Tychem 10000 listing and the Tychem 10000 fabric page (test data, standards).
DuPont TK613T specifications
| Item | DuPont data |
|---|---|
| Part numbers | TK613TLYLG000100, TK613TLYXL000100, TK613TLY2X000100 |
| Style | TK613T |
| Series | Tychem 10000 |
| Type | Encapsulated Suit Level A |
| As DuPont titles it | Encap. Level A, Expanded Back, Rear Entry. Certified to NFPA 1990 (NFPA 1994, Class 2) 2022 edition |
| Fabric | multi-layer barrier films laminated to both sides of a 4.0 oz/yd2 polyester substrate |
| Basis weight | 12 oz/yd2 |
| Thickness | 28 mils |
| Seams | Double Taped |
| Closure | Rear Zipper with Double Storm Flap with Hook and Loop Closure |
| Hood | No hood |
| Boots or socks | Attached socks |
| Gloves | Attached gloves |
| Storm flap | Yes |
| Color | Lime Yellow (LY) |
| Sizes DuPont lists | Medium, Large, XL, 2XL, 3XL, 4XL |
| Sizes on this page | Large, XL, 2XL |
| Quantity per case, as DuPont packs it | 1 per case |
| Sold by | Each (1) |
| Prop 65 warning | Yes |
Source: DuPont product page (DuPont Tychem 10000 TK613T). Figures are as the manufacturer publishes them for the style.
Protection and standards, as DuPont states them
| Standard or property | DuPont data |
|---|---|
| Barrier, as DuPont describes the fabric | DuPont reports at least 30 minutes of barrier protection against 322 challenge chemicals with no observed breakthrough; a puncture- and tear-resistant fabric for the highest level of liquid splash protection in the Tychem line |
| NFPA 1990 | Certified to NFPA 1990 (2022 edition), as DuPont states |
| NFPA 1994 Class 2 | Certified to NFPA 1990 (NFPA 1994 Class 2, CBRN terrorism incidents), 2022 edition, as DuPont states |
| 16 CFR 1610 Class 1 | Wearing apparel flammability Class 1 (normal flammability), as DuPont prints it; see the heat and flame line |
| Heat and flame | DuPont: these garments will burn and possibly melt and are not to be worn near heat, open flames, sparks or in potentially explosive or flammable environments, nor over flame-resistant garments as a substitute for them |
| Permeation data | DuPont publishes normalized breakthrough times for 79 chemicals on this garment page; the first 12 are in the table below and the full list is in DuPont SafeSPEC |
Source: DuPont product page (DuPont Tychem 10000 TK613T). Ratings are as published by the manufacturer for this style; they are not a hazard assessment for any site.
Tychem 10000 fabric physical properties
| Property | Test method | Typical result, as DuPont prints it |
|---|---|---|
| Thickness | ASTM D1777 | 28 mils |
| Basis Weight | ASTM D3776 | 12 oz/yd2 |
| Burst Strength - Ball | ASTM D3787 | 185 lbf |
| Tear Resistance - Trap Tear (MD) | ASTM D5733 | 75 lbf |
| Tear Resistance - Trap Tear (CD) | ASTM D5733 | 56 lbf |
| Breaking Strength - Grab (MD) | ASTM D5034 | 151 lbf |
| Breaking Strength - Grab (CD) | ASTM D5034 | 170 lbf |
| Wearing Apparel Flammability | 16 CFR 1610 | Class 1 |
Source: DuPont product page (Fabric and Chemical Resistance Data) and DuPont technical data sheet. Figures are laboratory results on the fabric, not the complete garment, as DuPont notes.
Tychem 10000 permeation data, first 12 of 79 chemicals
| Chemical | CAS number | Phase | Normalized breakthrough (minutes) |
|---|---|---|---|
| Acetaldehyde | 75-07-0 | Liquid | >480 |
| Acetic acid (>95%) | 64-19-7 | Liquid | >480 |
| Acetic acid 2 ethoxy ethyl ester | 111-15-9 | Liquid | >480 |
| Acetic acid 2 methoxy ethyl ester | 110-49-6 | Liquid | >480 |
| Acetic acid ethenyl ester | 108-05-4 | Liquid | >480 |
| Acetic acid ethyl ester | 141-78-6 | Liquid | >480 |
| Acetic acid pentyl ester | 628-63-7 | Liquid | >480 |
| Acetic anhydride | 108-24-7 | Liquid | >480 |
| Acetic chloride | 75-36-5 | Liquid | >480 |
| Acetone | 67-64-1 | Liquid | >480 |
| Acetone cyanohydrin | 75-86-5 | Liquid | >480 |
| Acetonitrile | 75-05-8 | Liquid | >480 |
Source: DuPont SafeSPEC and the DuPont product page; the full table by chemical is in DuPont SafeSPEC. In many cases seams and closures have shorter breakthrough times than the fabric, as DuPont notes.
DuPont TK613T, as DuPont describes it
Features, as listed:
- Class 2 garments are designed for situations where there is an immediate danger to life and health (IDLH) and must be worn with a self-contained breathing apparatus (SCBA)
- Rear entry design keeps closure away from direct contact with frontal chemical exposure and provides ability to change air bottle on SCBA without removing the entire garment
- Expanded anti-fog faceshield provides wide 220 degree viewing angle. EX faceshield is three-layer laminate composed of 40 mil PVC/5 mil Teflon / 20 mil PVC
- Expanded back to accommodate self-contained air breathing apparatus (SCBA)
- Vapor tight zipper. Extra long to increase garment opening and aid donning and doffing
- Storm flap covers zipper which can be secured by the wearer with rugged hook and loop material to prevent intrusion at zipper
- Attached internal gloves composed of five layer laminate film for a broad range of chemical protection
- Integrated socks composed of garment material
DuPont's specification lines for the garment:
- The garment shall be an encapsulated Level A design
- The garment shall have double taped seams
- The tape used to cover the seams shall be a film composite with equal to or greater chemical resistance than the base fabric
- The garment shall be certified to NFPA 1994 Class 2 by an independent, third party laboratory
- The garment shall have an extra wide visor consisting of 3 layers - PVC 40 mil / Teflon 5 mil / PVC 20 mil
- The garment shall have a rear, gas-tight zipper closure
- The zipper shall be covered with a double storm flap with hook and loop closure
- The garment shall have an expanded back
Source: DuPont product page (DuPont Tychem 10000 TK613T). Wording is the manufacturer's; lines that make a claim rather than state a fact are left out.
What you get
One suit in lime yellow in the size you pick above. Sold by the each · 1 suit.
- TK613TLYLG000100 (Large): $1,293.00
- TK613TLYXL000100 (XL): $1,293.00
- TK613TLY2X000100 (2XL): $1,370.00
Related DuPont TK613T part numbers
| Style | Color | Option | Sold by | Sizes | Price from | Listing |
|---|---|---|---|---|---|---|
| TK613T | Lime Yellow | Standard | Each | 3 sizes | {{price:TK613T-LY}} | this page |
Every DuPont Tychem 10000 listing we stock is on the DuPont Tychem 10000 page (11 listings).
Source: Style, colour and option codes as DuPont prints them; prices are ours.
DuPont TK613T sizes
| Size | Fits (DuPont finished dimensions) | Part number | Price |
|---|---|---|---|
| Large | chest 46 3/4 - 50 1/4 in, height 5'9" - 6'3" | TK613TLYLG000100 | $1,293.00 |
| XL | chest 46 3/4 - 50 1/4 in, height 5'9" - 6'3" | TK613TLYXL000100 | $1,293.00 |
| 2XL | chest 49 3/4 - 53 1/4 in, height 6'3" - 6'5" | TK613TLY2X000100 | $1,370.00 |
Source: Sizes, fit ranges and part numbers as DuPont prints them (DuPont sizes to ANSI/ISEA 101 where its page says so); prices are ours.
DuPont TK613T questions
What does Tychem 10000 protect against? DuPont reports at least 30 minutes of barrier protection against 322 challenge chemicals with no observed breakthrough; a puncture- and tear-resistant fabric for the highest level of liquid splash protection in the Tychem line, as DuPont describes the fabric. DuPont titles the TK613T "Encap. Level A, Expanded Back, Rear Entry. Certified to NFPA 1990 (NFPA 1994, Class 2) 2022 edition".
What is Tychem made of? Tychem 10000 is multi-layer barrier films laminated to both sides of a 4.0 oz/yd2 polyester substrate, as DuPont describes it; DuPont reports at least 30 minutes of protection against 322 chemical challenges. The TK613T has double taped seams and a storm flap over the zipper.
What is the difference between Tyvek and Tychem? Tyvek is flash-spun high-density polyethylene: a barrier to particles and light liquid splash. Tychem adds a chemical barrier film coated or laminated to the fabric for chemical splash, with bound or taped seams. The TK613T is Tychem 10000; the Tyvek vs Tychem guide below sets the two lines side by side.
How many times can a disposable garment be worn? DuPont's answer: The decision on whether or not a garment has been contaminated is made by local managers responsible for PPE based on an analysis of the incident in which the garment was used. This analysis may include exposure time, chemicals involved, level of exposure, proximity to the actual release, tasks performed and environmental monitoring in the area in which the garment was worn. The TK613T is a limited-use garment: it is discarded once contaminated, damaged or altered, and DuPont's user information on the product page covers inspection before each use.
How is this garment sized? By chest and height on DuPont's finished-dimensions table: Medium fits chest 45 1/4 - 48 3/4 in; Large fits chest 46 3/4 - 50 1/4 in; XL fits chest 46 3/4 - 50 1/4 in; 2XL fits chest 49 3/4 - 53 1/4 in. The size table above carries the fit range for every size on this page.
What level of protection is level A? Level A is the EPA's highest level: a fully encapsulating vapor-tight suit worn with SCBA; Level B is a liquid-splash suit with SCBA. DuPont titles the TK613T "Encap. Level A, Expanded Back, Rear Entry. Certified to NFPA 1990 (NFPA 1994, Class 2) 2022 edition" and states NFPA 1990, NFPA 1994 Class 2.
Guides: Tyvek vs Tychem · What is a hazmat suit, and what are the EPA protection · Hazmat suit levels A, B, C and D explained, and which ones · Permeation versus penetration · Seam types on disposable coveralls · How to clean up a chemical spill · disposable coverall fabrics compared.
DuPont TK613T documents
- DuPont user manual (encapsulated garments, level a)
- DuPont user manual (non-encapsulated garments)
- DuPont hazard matrix
- DuPont Tychem 10000 TK613T product page (features, size chart, permeation data)
- DuPont SafeSPEC (search by chemical or hazard)
Source: DuPont product page document links.
Manufacturer item number: TK613TLY.