Description
The 3M 2078 is the P95 particulate filter, a particulate filter for 3M bayonet facepieces (6000 Series half and full, 6500/6500QL, 7500, FF-400 and 7800S). The 3M chart lists it for P95. 3M pack: 100 EA/Case. Sold by the pair. Ships in 1–2 business days; most orders arrive in 3–7 business days.
3M 2078 specifications
| Item | Manufacturer data |
|---|---|
| 3M part number | 2078 |
| 3M name | Particulate Filter 2078, P95, with Nuisance Level Organic Vapor/Acid Gas Relief |
| Type | Particulate filter |
| NIOSH classes (3M chart) | P95 |
| 3M chart row | P95; Nuis OV/AG; OZ ticked (3M Cartridge and Filter Summary (2024); 3M 6000 Series half facepiece user instructions Table 7) |
| Fits | 3M bayonet facepieces: 6000 Series half (6100/6200/6300), 6500/6500QL Series, 7500 Series, 6000 Series full (6700/6800/6900), FF-400 Series, 7800S Series (3M Cartridge and Filter Summary (2024) row group "Bayonet-style 3M Reusable Respirators"; 3M 6500 Series spec sheet (2025) Approvals; 3M FF-400 Series specifications (US) Approvals; 3M Reusable Respirator Catalog (NIOSH) platform tables) |
| 3M pack | 100 EA/Case |
| End-of-service-life indicator | No end-of-service-life indicator is stated for this part in the documents fetched; 3M cartridge change schedules are set by the employer (3M 6000 Series half facepiece user instructions "Cartridge and Filter Replacement"). |
Source: 3M Cartridge and Filter Summary (2024); 3M.com product listings (November 2026).
3M stock numbers on this page
| 3M stock number | 3M part number | 3M.com listing name | UPC | Previous stock number |
|---|---|---|---|---|
| 7000052066 | 2078 | 3M Particulate Filter 2078, P95, with Nuisance Level Organic Vapor/Acid Gas Relief 100 EA/Case | 50051138543681 | 70070757904 |
Source: 3M.com product listings (November 2026); distributor product pages where 3M.com returned no card.
What the 3M chart lists for the 2078
| NIOSH class or note | Status |
|---|---|
| P95 | Listed by the 3M chart |
| Nuisance level relief (not a NIOSH class) | Nuis OV/AG — 3M suggested for nuisance odor relief from exposure concentrations not exceeding the OSHA PEL or applicable government occupational exposure limits, whichever is lower |
| Ozone (not a NIOSH class) | 3M recommendation only; the chart notes the part is not NIOSH approved for ozone |
Source: 3M Cartridge and Filter Summary (2024), cartridge and filter table; 3M 6000 Series half facepiece user instructions, Tables 6 and 7.
3M use notes for the 2078
Nuisance level refers to concentrations not exceeding the OSHA PEL or applicable government occupational exposure limits, whichever is lower. Nuisance-level relief is a 3M suggestion, not a NIOSH approval class. (3M Cartridge and Filter Summary (2024) note 2; 3M 6000 Series half facepiece user instructions Table 7 footnote 3)
2078 is 3M recommended for use against up to 1 ppm ozone for up to 40 hours. Not NIOSH or Brazil Ministry of Labor approved for use against ozone. (3M 6000 Series half facepiece user instructions Table 7 footnote 1)
For P series filters only when used in environments containing oil aerosols: Dispose of P-Series filters after 40 hours of use or 30 days, whichever is first. (3M Cartridge and Filter Guide (brochure 70-0714-8870-7))
Source: 3M Cartridge and Filter Summary (2024); 3M 6000 Series half facepiece user instructions; 3M Cartridge and Filter Guide (brochure 70-0714-8870-7).
3M facepieces that take the 2078
| Series | Type | Part numbers |
|---|---|---|
| 6000 Series half facepiece | Half facepiece | 6100, 6200, 6300 |
| 6500 Series Rugged Comfort half facepiece | Half facepiece | 6501, 6502, 6503, 6501QL, 6502QL, 6503QL |
| 7500 Series half facepiece | Half facepiece | 7501, 7502, 7503 |
| 6000 Series full facepiece | Full facepiece | 6700, 6800, 6900, 6800DIN, 6900DIN |
| FF-400 Series Ultimate FX full facepiece | Full facepiece | FF-401, FF-402, FF-403 |
| 7800S Series full facepiece | Full facepiece | 7800S-M, 7800S-L |
Source: 3M Cartridge and Filter Summary (2024) (row group "Bayonet-style 3M Reusable Respirators"); 3M 6500 Series spec sheet (2025); 3M FF-400 Series specifications (US); 3M Reusable Respirator Catalog (NIOSH).
NIOSH approvals naming the 2078
The NIOSH Certified Equipment List carries 58 current 3M Company approvals whose product line names it: 58 air-purifying particulate (TC-84A). The first 12:
| Approval | Product line | For protection against | Facepiece |
|---|---|---|---|
| TC-84A-2383 | 5X01 series w/2078 filter | — | Half Mask |
| TC-84A-2385 | 5X03 series w/2078 filter | — | Half Mask |
| TC-84A-2389 | 6X00, 7501, 7502, 7503 w/2078 filter | P95 | Half Mask |
| TC-84A-2390 | 6X00, 7501, 7502, 7503 w/2078 filter and 6001 cart. | Organic Vapor, P95 | Half Mask |
| TC-84A-2391 | 6X00, 7501, 7502, 7503 w/2078 filter and 6002 cart. | Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Sulfide, P95, Sulfur Dioxide | Half Mask |
| TC-84A-2392 | 6X00, 7501, 7502, 7503 w/2078 filter and 6003 cart. | Chlorine, Hydrogen Chloride, Hydrogen Sulfide, Organic Vapor, P95, Sulfur Dioxide | Half Mask |
| TC-84A-2393 | 6X00, 7501, 7502, 7503 w/2078 filter and 6004 cart. | Ammonia, Methylamine, P95 | Half Mask |
| TC-84A-2394 | 6X00, 7501, 7502, 7503 w/2078 filter and 6005 cart. | Formaldehyde, Organic Vapor, P95 | Half Mask |
| TC-84A-2395 | 6X00, 7501, 7502, 7503 w/2078 filter and 6006 cart. | Ammonia, Chlorine, Chlorine Dioxide, Formaldehyde, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Methylamine, Organic Vapor, P95 … | Half Mask |
| TC-84A-2406 | 7800 neg. press. w/2078 filter | P95 | Full Facepiece |
| TC-84A-2407 | 7800 neg. press. w/2078 filter and 6001 cart. | Organic Vapor, P95 | Full Facepiece |
| TC-84A-2408 | 7800 neg. press. w/2078 filter and 6002 cart. | Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Sulfide, P95, Sulfur Dioxide | Full Facepiece |
Source: NIOSH Certified Equipment List (November 2026), manufacturer 3M Company.
Every 3M bayonet cartridge and filter we list
| Part number | 3M name | NIOSH classes (3M chart) | Label color |
|---|---|---|---|
| 6001 | Organic Vapor Cartridge 6001 | Organic Vapor | Black |
| 6002 | Acid Gas Cartridge 6002 | Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Sulfide, Sulfur Dioxide | White |
| 6003 | Organic Vapor/Acid Gas Cartridge 6003 | Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide | Yellow |
| 6004 | Ammonia Methylamine Cartridge 6004 | Ammonia, Methylamine | Green |
| 6005 | Formaldehyde/Organic Vapor Cartridge 6005 | Organic Vapor, Formaldehyde | Olive/Black |
| 6006 | Multi Gas/Vapor Cartridge 6006 | Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde | Olive |
| 60921 | Organic Vapor Cartridge/Filter 60921, P100 | Organic Vapor, P100 | — |
| 60922 | Acid Gas Cartridge/Filter 60922, P100 | Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Sulfide, Sulfur Dioxide, P100 | — |
| 60923 | Organic Vapor/Acid Gas Cartridge/Filter 60923, P100 | Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, P100 | — |
| 60924 | Ammonia/Methylamine/Filter 60924, P100 | Ammonia, Methylamine, P100 | — |
| 60925 | Formaldehyde Organic Vapor Cartridge/Filter 60925, P100 | Organic Vapor, Formaldehyde, P100 | — |
| 60926 | Multi Gas/Vapor Cartridge/Filter 60926, P100 | Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde, P100 | — |
| 60927 | Mercury Vapor/Organic Vapor/Acid Gas Cartridge/Filter 60927, P100 | Organic Vapor, Chlorine, Hydrogen Sulfide, Sulfur Dioxide, Mercury Vapor, P100 | — |
| 60928 | Organic Vapor/Acid Gas Cartridge/Filter 60928, P100 | Organic Vapor, Sulfur Dioxide, Hydrogen Chloride, Chlorine, Hydrogen Fluoride, Hydrogen Sulfide, P100 | — |
| 2071 | Particulate Filter 2071, P95 | P95 | — |
| 2076HF | Particulate Cartridge 2076HF, Hydrogen Fluoride, P95, with Nuisance Level Acid Gas Relief | Hydrogen Fluoride, P95 | — |
| 2091 | Particulate Filter 2091, P100 | P100 | — |
| 2291 | Advanced Particulate Filter 2291, P100 | P100 | — |
| 2096 | Particulate Filter 2096, P100, with Nuisance Level Acid Gas Relief | P100 | — |
| 2296 | Advanced Particulate Filter 2296, P100, with Nuisance Level Acid Gas Relief | P100 | — |
| 2097 | Particulate Filter 2097, P100, with Nuisance Level Organic Vapor Relief | P100 | — |
| 2297 | Advanced Particulate Filter 2297, P100, with Nuisance Level Organic Vapor Relief | P100 | — |
| 7093 | Particulate Filter 7093, P100 | P100 | — |
| 7093B | Particulate Filter 7093B, P100 | P100 | — |
| 7093C | Hydrogen Fluoride Cartridge/Filter 7093C, P100, with Nuisance Level Organic Vapor and Acid Gas Relief | Hydrogen Fluoride, P100 | — |
| 7093CB | Hydrogen Fluoride Cartridge/Filter 7093CB, P100, with Nuisance Level Organic Vapor and Acid Gas Relief | Hydrogen Fluoride, P100 | — |
| 5N11 | Particulate Filter 5N11, N95 | N95 | — |
| 5P71 | Particulate Filter 5P71, P95 | P95 | — |
Source: 3M Cartridge and Filter Summary (2024).
Catalog data
| Item | Manufacturer data |
|---|---|
| Filter Rating | P95 |
| Color | White |
| Filter Class | P95 |
Source: Manufacturer published product data as carried in our catalog.
3M™ 2078 particulate filters are rated NIOSH P95 against oil and non-oil particles and add relief from nuisance levels of organic vapors and acid gases. They attach with the 3M bayonet connection to 3M 6000, 6500, 7500, 7800S and FF-400 Series half and full facepieces.
- Lightweight and easy to breathe through
- Bayonet connection fits many 3M half and full facepieces and certain 3M Scott full facepieces
Sold by the pair (2 filters per pack).
3M 2078 questions
What does the 3M 2078 protect against? The 3M chart lists P95. Nuisance-level relief and ozone notes are 3M recommendations, not NIOSH approvals, where the chart marks them.
Which 3M facepieces take the 2078? 3M bayonet facepieces: 6000 Series half (6100/6200/6300), 6500/6500QL Series, 7500 Series, 6000 Series full (6700/6800/6900), FF-400 Series, 7800S Series (3M Cartridge and Filter Summary (2024) row group "Bayonet-style 3M Reusable Respirators"; 3M 6500 Series spec sheet (2025) Approvals; 3M FF-400 Series specifications (US) Approvals; 3M Reusable Respirator Catalog (NIOSH) platform tables).
How does 3M pack the 2078? 100 EA/Case.
Does the 2078 have an end-of-service-life indicator? No end-of-service-life indicator is stated for this part in the documents fetched; 3M cartridge change schedules are set by the employer (3M 6000 Series half facepiece user instructions "Cartridge and Filter Replacement").
Guides: cartridge change schedules · P100 vs N95 vs R95 · half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · all respirators by model and hazard.