Skip to main content
3M™

3M 2076HF P95 Particulate Cartridge, Hydrogen Fluoride, Nuisance Acid Gas Relief

Item # 7000021310
$6.29

The 3M 2076HF is the P95 particulate cartridge, a combination cartridge and filter for 3M bayonet facepieces (6000 Series half and full, 6500/6500QL, 7500, FF-400 and 7800S). The 3M chart lists it for Hydrogen Fluoride, P95. 3M pack: 100 EA/Case. Sold by the each. Ships in 1–2 business days; most orders arrive in 3–7 business days.

3M 2076HF specifications

ItemManufacturer data
3M part number2076HF
3M nameParticulate Cartridge 2076HF, Hydrogen Fluoride, P95, with Nuisance Level Acid Gas Relief
TypeCombination cartridge and filter
NIOSH classes (3M chart)Hydrogen Fluoride, P95
3M chart rowHF + P95; Nuis AG (3M Cartridge and Filter Summary (2024); 3M 6000 Series half facepiece user instructions Table 7)
Fits3M bayonet facepieces: 6000 Series half (6100/6200/6300), 6500/6500QL Series, 7500 Series, 6000 Series full (6700/6800/6900), FF-400 Series, 7800S Series (3M Cartridge and Filter Summary (2024) row group "Bayonet-style 3M Reusable Respirators"; 3M 6500 Series spec sheet (2025) Approvals; 3M FF-400 Series specifications (US) Approvals; 3M Reusable Respirator Catalog (NIOSH) platform tables)
3M pack100 EA/Case
End-of-service-life indicatorNo end-of-service-life indicator is stated for this part in the documents fetched; 3M cartridge change schedules are set by the employer (3M 6000 Series half facepiece user instructions "Cartridge and Filter Replacement").

Source: 3M Cartridge and Filter Summary (2024); 3M.com product listings (November 2026).

3M stock numbers on this page

3M stock number3M part number3M.com listing nameUPCPrevious stock number
70000213102076HF3M Particulate Cartridge 2076HF, Hydrogen Fluoride, P95, with Nuisance Level Acid Gas Relief 100 EA/Case5005113854369870070757912

Source: 3M.com product listings (November 2026); distributor product pages where 3M.com returned no card.

What the 3M chart lists for the 2076HF

NIOSH class or noteStatus
Hydrogen FluorideListed by the 3M chart
P95Listed by the 3M chart
Nuisance level relief (not a NIOSH class)Nuis AG — 3M suggested for nuisance odor relief from exposure concentrations not exceeding the OSHA PEL or applicable government occupational exposure limits, whichever is lower

Source: 3M Cartridge and Filter Summary (2024), cartridge and filter table; 3M 6000 Series half facepiece user instructions, Tables 6 and 7.

3M use notes for the 2076HF

Nuisance level refers to concentrations not exceeding the OSHA PEL or applicable government occupational exposure limits, whichever is lower. Nuisance-level relief is a 3M suggestion, not a NIOSH approval class. (3M Cartridge and Filter Summary (2024) note 2; 3M 6000 Series half facepiece user instructions Table 7 footnote 3)

For P series filters only when used in environments containing oil aerosols: Dispose of P-Series filters after 40 hours of use or 30 days, whichever is first. (3M Cartridge and Filter Guide (brochure 70-0714-8870-7))

Source: 3M Cartridge and Filter Summary (2024); 3M 6000 Series half facepiece user instructions; 3M Cartridge and Filter Guide (brochure 70-0714-8870-7).

3M facepieces that take the 2076HF

SeriesTypePart numbers
6000 Series half facepieceHalf facepiece6100, 6200, 6300
6500 Series Rugged Comfort half facepieceHalf facepiece6501, 6502, 6503, 6501QL, 6502QL, 6503QL
7500 Series half facepieceHalf facepiece7501, 7502, 7503
6000 Series full facepieceFull facepiece6700, 6800, 6900, 6800DIN, 6900DIN
FF-400 Series Ultimate FX full facepieceFull facepieceFF-401, FF-402, FF-403
7800S Series full facepieceFull facepiece7800S-M, 7800S-L

Source: 3M Cartridge and Filter Summary (2024) (row group "Bayonet-style 3M Reusable Respirators"); 3M 6500 Series spec sheet (2025); 3M FF-400 Series specifications (US); 3M Reusable Respirator Catalog (NIOSH).

NIOSH approvals naming the 2076HF

The NIOSH Certified Equipment List carries 56 current 3M Company approvals whose product line names it: 56 air-purifying particulate (TC-84A). The first 12:

ApprovalProduct lineFor protection againstFacepiece
TC-84A-23136000 series, 7501, 7502, 7503 w/2076HF filterHydrogen Fluoride, P95Half Mask
TC-84A-23146000 series, 7501, 7502, 7503 w/2076HF filter and 6001 cart.Hydrogen Fluoride, Organic Vapor, P95Half Mask
TC-84A-23156000 series, 7501, 7502, 7503 w/2076HF filter and 6002 cart.Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, P95, Sulfur DioxideHalf Mask
TC-84A-23166000 series, 7501, 7502, 7503 w/2076HF filter and 6003 cart.Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Organic Vapor, P95, Sulfur DioxideHalf Mask
TC-84A-23176000 series, 7501, 7502, 7503 w/2076HF filter and 6004 cart.Ammonia, Hydrogen Fluoride, Methylamine, P95Half Mask
TC-84A-23186000 series, 7501, 7502, 7503 w/2076HF filter and 6005 cart.Formaldehyde, Hydrogen Fluoride, Organic Vapor, P95Half Mask
TC-84A-23196000 series, 7501, 7502, 7503 w/2076HF filter and 6006 cart.Ammonia, Chlorine, Chlorine Dioxide, Formaldehyde, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Methylamine, Organic Vapor, P95 …Half Mask
TC-84A-23307800 neg. press. w/2076HF filterHydrogen Fluoride, P95Full Facepiece
TC-84A-23317800 neg. press. w/2076HF filter and 6001 cart.Hydrogen Fluoride, Organic Vapor, P95Full Facepiece
TC-84A-23327800 neg. press. w/2076HF filter and 6002 cart.Chlorine, Chlorine Dioxide, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, P95, Sulfur DioxideFull Facepiece
TC-84A-23337800 neg. press. w/2076HF filter and 6003 cart.Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Organic Vapor, P95, Sulfur DioxideFull Facepiece
TC-84A-23347800 neg. press. w/2076HF filter and 6004 cart.Ammonia, Hydrogen Fluoride, Methylamine, P95Full Facepiece

Source: NIOSH Certified Equipment List (November 2026), manufacturer 3M Company.

Every 3M bayonet cartridge and filter we list

Part number3M nameNIOSH classes (3M chart)Label color
6001Organic Vapor Cartridge 6001Organic VaporBlack
6002Acid Gas Cartridge 6002Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Sulfide, Sulfur DioxideWhite
6003Organic Vapor/Acid Gas Cartridge 6003Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur DioxideYellow
6004Ammonia Methylamine Cartridge 6004Ammonia, MethylamineGreen
6005Formaldehyde/Organic Vapor Cartridge 6005Organic Vapor, FormaldehydeOlive/Black
6006Multi Gas/Vapor Cartridge 6006Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, FormaldehydeOlive
60921Organic Vapor Cartridge/Filter 60921, P100Organic Vapor, P100—
60922Acid Gas Cartridge/Filter 60922, P100Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Sulfide, Sulfur Dioxide, P100—
60923Organic Vapor/Acid Gas Cartridge/Filter 60923, P100Organic Vapor, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, P100—
60924Ammonia/Methylamine/Filter 60924, P100Ammonia, Methylamine, P100—
60925Formaldehyde Organic Vapor Cartridge/Filter 60925, P100Organic Vapor, Formaldehyde, P100—
60926Multi Gas/Vapor Cartridge/Filter 60926, P100Organic Vapor, Chlorine Dioxide, Chlorine, Hydrogen Chloride, Hydrogen Fluoride, Hydrogen Sulfide, Sulfur Dioxide, Ammonia, Methylamine, Formaldehyde, P100—
60927Mercury Vapor/Organic Vapor/Acid Gas Cartridge/Filter 60927, P100Organic Vapor, Chlorine, Hydrogen Sulfide, Sulfur Dioxide, Mercury Vapor, P100—
60928Organic Vapor/Acid Gas Cartridge/Filter 60928, P100Organic Vapor, Sulfur Dioxide, Hydrogen Chloride, Chlorine, Hydrogen Fluoride, Hydrogen Sulfide, P100—
2071Particulate Filter 2071, P95P95—
2078Particulate Filter 2078, P95, with Nuisance Level Organic Vapor/Acid Gas ReliefP95—
2091Particulate Filter 2091, P100P100—
2291Advanced Particulate Filter 2291, P100P100—
2096Particulate Filter 2096, P100, with Nuisance Level Acid Gas ReliefP100—
2296Advanced Particulate Filter 2296, P100, with Nuisance Level Acid Gas ReliefP100—
2097Particulate Filter 2097, P100, with Nuisance Level Organic Vapor ReliefP100—
2297Advanced Particulate Filter 2297, P100, with Nuisance Level Organic Vapor ReliefP100—
7093Particulate Filter 7093, P100P100—
7093BParticulate Filter 7093B, P100P100—
7093CHydrogen Fluoride Cartridge/Filter 7093C, P100, with Nuisance Level Organic Vapor and Acid Gas ReliefHydrogen Fluoride, P100—
7093CBHydrogen Fluoride Cartridge/Filter 7093CB, P100, with Nuisance Level Organic Vapor and Acid Gas ReliefHydrogen Fluoride, P100—
5N11Particulate Filter 5N11, N95N95—
5P71Particulate Filter 5P71, P95P95—

Source: 3M Cartridge and Filter Summary (2024).

Catalog data

ItemManufacturer data
StyleParticulate Filter
Filter ClassP100

Source: Manufacturer published product data as carried in our catalog.

A 3M 2076HF combination filter for half and full facepiece respirators. It stops oil and non-oil particles and hydrogen fluoride, adds relief from nuisance acid gas odors, and breathes easier than a cartridge and filter stack.

  • P100 filter for oil and non-oil particulates
  • Hydrogen fluoride protection up to 10 times PEL
  • Relief from nuisance levels of acid gases
  • Fits 3M 5000, 6000, 6500, 7000 and FF-400 series facepieces
  • Flexible, abrasion-resistant design for tight spaces

3M 2076HF questions

What does the 3M 2076HF protect against? The 3M chart lists Hydrogen Fluoride, P95. Nuisance-level relief and ozone notes are 3M recommendations, not NIOSH approvals, where the chart marks them.

Which 3M facepieces take the 2076HF? 3M bayonet facepieces: 6000 Series half (6100/6200/6300), 6500/6500QL Series, 7500 Series, 6000 Series full (6700/6800/6900), FF-400 Series, 7800S Series (3M Cartridge and Filter Summary (2024) row group "Bayonet-style 3M Reusable Respirators"; 3M 6500 Series spec sheet (2025) Approvals; 3M FF-400 Series specifications (US) Approvals; 3M Reusable Respirator Catalog (NIOSH) platform tables).

How does 3M pack the 2076HF? 100 EA/Case.

Does the 2076HF have an end-of-service-life indicator? No end-of-service-life indicator is stated for this part in the documents fetched; 3M cartridge change schedules are set by the employer (3M 6000 Series half facepiece user instructions "Cartridge and Filter Replacement").

Guides: cartridge change schedules · P100 vs N95 vs R95 · half mask vs full facepiece · assigned protection factors · what OSHA requires for fit testing · cleaning and storing respirators · all respirators by model and hazard.

Usually ships in 1–2 business days; delivery in 3–7 business days.

Adding to cart… The item has been added
Sold by the Each
Specifications
StyleCombination cartridge with filter
StandardsNIOSH 42 CFR 84
Filter ClassP100
3M Part Number2076HF
ProtectionHydrogen Fluoride, P95
NIOSH RatingP95
Cartridge Connection3M Bayonet
Manufacturer Pack100 EA/Case
Shipping & returns

In-stock orders: 1–2 business days to process, then 2–5 business days by ground (3–7 in all); regular rates apply and Contractor Direct orders ship free. Most items can be returned within 30 days in new, resalable condition; respirators, filters and other hygiene items are final sale. Shipping policy · Returns policy

3M 2076HF P95 Particulate Cartridge, Hydrogen Fluoride, Nuisance Acid Gas Relief$6.29

More 3M™ and other brands in this category

Reviews

No reviews yet. Used this on the job? Tell other crews how it held up.

Write a review ›
How to buyCard, purchase order or invoice terms; quotes on request; agencies and institutions welcome.
Live Service & SupportReal people who know the products, Monday to Friday 7:30am to 4pm Pacific. 925-215-7337
We DeliverWe ship nationwide. Parcel and LTL freight to job sites and businesses across the U.S.