Description
The Draeger 8103501 is the Carbon tetrachloride 0.1/a detector tube, measuring range 0.1 to 5 ppm, 5 pump strokes, measuring time approx. 2.5 min (handbook, p. 151). Sold by the box of 10, 10 single-use tubes. Read on a Draeger accuro or X-act 5000 tube pump. Ships in 1–2 business days; most orders arrive in 3–7 business days. All Draeger tubes for Carbon tetrachloride.
Draeger 8103501 specifications
| Item | Draeger data |
|---|---|
| Part number | 8103501 |
| Gas or substance | Carbon tetrachloride |
| Tube type | 0.1/a |
| Measuring range | 0.1 to 5 ppm |
| Number of strokes (n) | 5 |
| Measuring time | approx. 2.5 min |
| Standard deviation | ± 20 to 30 % |
| Color change | yellow → blue-green |
| Temperature | 2 to 40 °C |
| Humidity | 1 to 40 mg/L |
| Reaction principle | a) CCl4 + H2S2O7 → COCl2 b) COCl2 + diethylaniline + dimethylaminobenzaldehyde → blue-green reaction product |
| Pack | Box of 10 |
| Pump | Read on a Draeger accuro or X-act 5000 tube pump |
Source: Dräger-Tubes & MicroTubes Handbook, 22nd edition (order no. 90 92 086), p. 151, Dräger Safety AG & Co. KGaA.
Cross-sensitivity (handbook, p. 151): Phosgene is indicated with around the same sensitivity as carbon tetrachloride. 50 ppm perchloroethylene gives a reading of approx. 1 to 2 ppm, 50 ppm trichloroethylene and 1,1,-dichloroethylene give a weak reading of < 0.1 ppm. The indication is not affected by: 10ppm vinyl chloride 200 ppm 1,2-dichloroethylene
Carbon tetrachloride exposure limits
| Limit | Value |
|---|---|
| OSHA PEL | TWA 10 ppm C 25 ppm 200 ppm (5-minute maximum peak in any 4 hours) |
| NIOSH REL | Ca ST 2 ppm (12.6 mg/m³) [60-minute] |
| NIOSH IDLH | Ca [200 ppm] |
| CAS number | 56-23-5 |
| Formula | CCl₄ |
| Conversion | 1 ppm = 6.29 mg/m³ |
Source: NIOSH Pocket Guide to Chemical Hazards, Carbon tetrachloride (OSHA PEL from 29 CFR 1910.1000 Table Z as listed there). TWA = 8-hour time-weighted average, ST = short-term (15-minute), C = ceiling, Ca = NIOSH potential occupational carcinogen.
Other Draeger tubes for Carbon tetrachloride
| Part number | Tube | Measuring range | Pack |
|---|---|---|---|
| 8101021 | Draeger Carbon Tetrachloride 1/a Detector Tubes, Box of 10 | 1 to 15 ppm / 10 to 50 ppm | Box of 10 |
Every Draeger tube for this gas, with live prices: Carbon tetrachloride detector tubes.
Draeger 8103501 questions
What does the Draeger 8103501 measure? Carbon tetrachloride in air, measuring range 0.1 to 5 ppm.
How many pump strokes does the 8103501 take? 5 strokes (n) per the handbook, p. 151. Measuring time approx. 2.5 min.
Which pump does the 8103501 use? A Draeger tube pump: the accuro hand pump or the X-act 5000. Per the handbook (p. 28–29), Draeger short-term tubes and Draeger tube pumps are matched at the factory and form a single unit; using other pumps with Draeger tubes, or other tubes with Draeger pumps, can impair the measurement.
What is the color change on the 8103501? yellow → blue-green, read against the scale printed on the tube.
Do Draeger 8103501 tubes expire? Yes. Draeger prints an expiration date (month and year) on the package; the handbook states a typical shelf life for the customer of up to two years, stored sealed at the temperature on the package strip (handbook section 2.13).
How many tubes are in a box of 8103501? 10. Each tube is used once.
Guides: what Draeger tubes measure · pump strokes and measuring time · how to read a tube · expiration and storage · cross-sensitivity · all tubes by gas and range.